Laserfiche WebLink
INITIATING WIRING RECORD DRAWINGS <br /> AS-BUILT/RECORD DRAWING REQUIREMENTS: CO nve rg j nt' <br /> SIGNATURE LOOP WIRING LIMITATIONS: <br /> THE FOLLOWING INFORMATION SHOULD BE RECORDED ON A SEPARATE SET OF O <br /> SIGNATURE DUAL DRIVER CONTROLLER MODULES SUPPORTS UP TO 250 DRAWINGS FOR EACH PROJECT: <br /> INTELLIGENT SIGNATURE DETECTORS AND 250 INTELLIGENT SIGNATURE o 450 Shattuck Avenue South,Renton,Washington 98057 <br /> MODULES 1. ANY CHANGES IN THE LOCATION OF ANY ASSOCIATED FIRE ALARM OR a W o w Phone:425-272-2250 Fax:425-251-0949 <br /> WIRE LENGTH LIMITATIONS: INTERFACE EQUIPMENT.CONTROL PANELS,ANNUNCIATORS,DETECTORS, o 0- <br /> CONTROL RELAYS,INPUT AND OUTPUT MODULES,TERMINAL CABINETS, a �" 'm 0 <br /> NON-TWISTED,NON-SHIELDED WIRE ETC. LL This document ana the Inf-eaGNdeplcanns mnWinedlshown <br /> 16AWG-20pf/FT&4.02 OHMS 1000 FEET 2. ANY CHANGES TO CIRCUIT WIRING.THIS INCLUDES DELETION OR SEQUENCE OF OPERATIONS ¢ 0 0 o m w w is the e.dwsmePrepery OfCOT-mint Te,hnoloaies uC and shall <br /> 18AWG-20pfIFT&6.38 OHMS/1000 FEET ADDITIONAL WIRING RUNS.ANY RE-ROUTING OF CIRCUIT WIRING.ANY -0 be handled as prepnetary and wnfidential information ana must be <br /> DETECTORS ONLY 16AWG-125 DETECTORS-9.275' ADDITIONS OR DELETIONS TO THE NUMBER,LOCATION,AND ORDER OF a i w 3 a N retu..d upon request.This dowmenl cannot be reproduced by any <br /> MODULES ONLY 16AWG-125 MODULES-7,921' DEVICE WIRING ON A CIRCUIT. ' ens without the wdtlen eulhodzatlon of Convergint Technologies LLC. <br /> o <br /> DETECTORS AND MODULES 1 <br /> 6AWG-125 OF EACH-3,608' 3. ADDRESSES AND/OR LABELS FOR ALL ADDRESSABLE DEVICES. p 'J <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' 4. CANDELA SETTINGS OF ALL VISUAL NOTIFICATION DEVICES. <br /> MODULES ONLY 18AWG-125 MODULES-4,986' 5. WATTAGE TAP SETTINGS OF ALL SPEAKER NOTIFICATION DEVICES. <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2,271' <br /> ANY CHANGES SHALL BE DISCUSSED WITH CONVERGINT PROJECT MANAGER <br /> TWISTED PAIR,NON-SHIELDED WIRE TO ENSURE SYSTEM AND CODE PARAMETERS ARE MET.CONVERGINT SHALL <br /> 16AWG-36pf/FT&4.02 OHMS/1000 FEET NOT BE HELD ACCOUNTABLE FOR CHANGES MADE WITHOUT APPROVAL. <br /> 18AWG-25pf/FT&6.38 OHMS/1000 FEET <br /> DETECTORS ONLY 16AWG-125 DETECTORS-9,275' THIS INFORMATION SHALL BE NEAT AND LEGIBLE WHEN PRESENTED TO THE v v v v v v V <br /> MODULES ONLY 1GAWG-125 MODULES <br /> -7,921' TECHNICIAN AT THE CONCLUSION OF THE PROJECT.PLEASE NOTE CONTACT ACTIVATION OF LOCAL ALARM AT UT&2120 HEADEND(LED DISP,ZONE LED&AUDIBLE IND.) X X X X A A A <br /> DETECTORS AND MODULES 16AWG-125 OF EACH-3,608' INFORMATION ON DRAWINGS FOR INDIVIDUALS WITH FAMILIARITY OF <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' INSTALLATION IN THE EVENT QUESTIONS ARISE DURING THE CLOSEOUT ACTIVATE ALL AUDIBLE&VISIBLE ALARMS X X X X X X <br /> MODULES ONLY 18AWG-125 MODULES-4,986 PROCESS. <br /> DETECTORS AND MODULES 18AWG-125 OF EACH-2.271' IN DICATION OF ALARM ON AN N UNCIATOR X X X X X X X <br /> 16AWG TWISTED PAIR,&4.02 SHIELDED WIRE NETWORK WIRING X <br /> 16AWG-82pf/FT&4.02 OHMS/1000 FEET IN ITIATE PRI MARY ELEV.RECALL SEQUENCE TO MAIN FLOOR(IF APPLICABLE) <br /> 18AWG-58pf/FT&6.38 OHMS/1000 FEET <br /> DETECTORS ONLY i6AWG-125 DETECTORS-6,098' DATA NETWORK SPECIFICATIONS: INITIATE ALTERNATE ELEV.RECALL SEQUENCE TO FIRST FLOOR(IF APPLICABLE) X <br /> MODULES ONLY 16AWG-125 MODULES-6,098' <br /> DETECTORS AND MODULES 16AWG-125 OF EACH-S-51 MAXIMUM ALLOWED VALUES BETWEEN ANY THREE NODES OF A NETWORK. RELEASE ALL DOOR HOLDERS&CLOSURES ON FLOOR IN ALARM(OR GEN.ALARM) y x y x x y <br /> DETECTORS ONLY 18AWG-125 DETECTORS-5,839' • RESISTANCE:90 OHMS ^ X ^ ^ ^ ^ <br /> MODULES ONLY 18AWG-125 MODULES-,271' • CAPACITANCE:0.3 MICROFARADS <br /> DETECTORS AND MODULES 18AWG-1250F EACH-2,271' DISTANCE:5,000 FEET TRAMS MITTROUBLES,SUPERVISORYSIGNATURE 0­LOOP WIRING c-ASS E O­ SIGNATURE DATA LOOP.o-ASS BONLY X X X X X X <br /> THE FOLLOWING TABLE LISTS THE MAXIMUM CUMULATIVE CAPACITANCE FOR TRANSMITALARM SIGNALTO CENTRAL STATION MONITOR X X X X X X <br /> THE ENTIRE DATA NETWORK GIVEN VARIOUS WIRE SIZES AND TRANSMISSION <br /> RATES.MAXIMUM CUMULATIVE CAPACITANCE IS THE TOTAL CAPACITANCE OF SHUTDOWN RESPECTIVE HVAC FAN I <br /> ,aoa,x n I.,of .aoP�h ALL INSTALLED COPPER WIRE USED IN THE DATA NETWORK. <br /> MAXIMUM CUMULATIVE CAPACITANCE IN MICROFARADS TROUBLE INDICATION ON FACP&ANNUNCIATOR X dx <br /> e0 em <br /> BAWG-1.4 D/2.8 @38.4K BAU@19.2K BAUD TRANSMITTROUBLE SIGNALTO CENTRALSTATION MON ITOR X <br /> i 6AWG-1.8 @ 38.4K BAUD/2.1 @ 19.2K BAUD <br /> US JNACCEPTAISUE 14AWG-2.1 @ 38.4K BAUD/4.2 @ 19.2K BAUD NOTE:THE SEQUENCE OF OPERATIONS IS NOT AFFECTED BY THE CHANGES MADE IN THIS PROJECT. <br /> CABLE PROPERTIES <br /> DATA AND AUDIO NETWORKS IN AN EST3 SYSTEM DO NOT REQUIRE THE USE OF <br /> SHIELDED CABLE,AND NETWORKS DESIGNED WITH TWISTED-PAIR CAN BE <br /> ABOUT TWICE AS LONG AS THOSE DESIGNED WITH SHIELDED CABLE.THE <br /> raoP,u o o re'. r_>..a ��GE- MAXIMUM LENGTH OF A DATA NETWORK VARIES WITH THE PROPERTIES OF THE <br /> WIRE USED.WIRE MANUFACTURERS TYPICALLY PROVIDE SPECIFICATIONS FOR <br /> WIRE RESISTANCE AND CAPACITANCE. <br /> eTAR-TARRiN..UH EPTAELE SURVIVABILITY WIRING <br /> PATHWAY SURVIVABILITY LEVELS <br /> PATHWAY SURVIVABILITY MUST MEET THE REQUIREMENTS OF NFPA 72;SECTION <br /> 12.4 FOR THE CORRESPONDING LEVEL OF SURVIVABILITY REQUIRED BY NFPA 72, <br /> NOTIFICATION WIRING CHAPTER 24.THE FOLLOWING IS A CONDENSED DESCRIPTION OF THE <br /> SURVIVABILITY LEVELS. <br /> SPEAKER CIRCUIT WIRING LIMITATIONS: PATHWAY SURVIVABILITY LEVEL 0.LEVEL 0 PATHWAY SHALL NOT BE REQUIRED TO <br /> WIRE LENGTH LIMITATIONS: HAVE ANY PROVISIONS FOR PATHWAY SURVIVABILITY. <br /> THE MAXIMUM ALLOWABLE WIRE LENGTH IS THE FARTHEST DISTANCE THAT A PATHWAY SURVIVABILITY LEVEL 1.PATHWAY INSTALLED IN FULLY SPRINKLED <br /> SPEAKER CIRCUIT CAN EXTEND FROM THE AMPLIFIER TO THE LAST SPEAKER BUILDING MEETING THE REQUIREMENTS OF NFPA 13 WITH ANY INTERCONNECTING <br /> WITHOUT LOSING 0.5 dB OF SIGNAL.THE FOLLOWING ARE MAXIMUM DISTANCE CONDUCTORS,CABLES OR OTHER PHYSICAL PATHWAYS INSTALLED IN METAL <br /> BASED ON APPROXIMATE WATTAGE OF THE SPEAKER CIRCUIT.CIRCUIT LENGTHS RACEWAYS. <br /> ARE FURTHER BASED ON ORIGINATION OF A CIRCUIT FROM EITHER THE PATHWAY SURVIVABILITY LEVEL 2.PATHWAY SURVIVABILITY LEVEL 2 SHALL <br /> AMPLIFIER OR FROM THE CCi MODULE. CONSIST OF ONE OR MORE OF THE FOLLOWING: <br /> ALLOWABLE LENGTH AT 25 Vrms,WITH 0.5 dB LOSS (1) 2-HOUR FIRE-RATED CIRCUIT INTEGRITY(CI)CABLE <br /> 16AWG-20 WATTS-231' (2) 2-HOUR FIRE-RATED CABLE SYSTEM[ELECTRICAL CIRCUIT PROTECTIVE <br /> 1 <br /> 6AWG-30 WATTS-154' SYSTEM(S)] <br /> 16AWG- 0 WATTS-154' (3) 2-HOUR FIRE RATED ENCLOSURE OR PROTECTED AREA <br /> (4) 2-HOUR PERFORMANCE ALTERNATIVES APPROVED BY THE AUTHORITY <br /> ALLOWABLE LENGTH AT 70 Vrms,WITH 0.5 dB LOSS HAVING JURISDICTION <br /> 16AWG-20 WATTS- <br /> 1815' PATHWAY SURVIVABILITY LEVEL 3.SAME AS LEVEL 2 WITH ADDITION OF BEING IN A <br /> 1 <br /> 6AWG-30 WATTS- FULLY <br /> i6AWG-40 WATTS-BOT SPRINKLED BUILDING MEETING THE REQUIREMENTS OF NFPA 13. <br /> 907' <br /> NAC CIRCUIT(HORN,STROBE)WIRING LIMITATIONS: CIRCUITS REQUIRING SURVIVABILITY BY NFPA 72 <br /> FOR 24VDC SYSTEMS,MINIMUM DEVICE OPERATING VOLTAGE IS 16VDC. THE FOLLOWING CIRCUIT TYPES,WHEN USED ARE REQUIRED TO BE SURVIVABLE <br /> VOLTAGE DROP CALCULATIONS ARE BASED ON 16VDC AND POWER SUPPLY AS DESCRIBED BELOW.REFER TO NFPA 72,CHAPTER 24 FOR ADDITIONAL <br /> DE-RATED AND ON DEPLETED BATTERY BACKUP PER THE PRESCRIBED PERIOD INFORMATION REGARDING CIRCUIT TYPES.THIS IS NOT A COMPLETE LIST AND IS <br /> OF STANDBY AND ALARM RING TIME.THE VOLTAGE DROP WILL LIMIT THE MEANT TO SUPPLEMENT ANY NOTES PROVIDED ELSEWHERE IN OUR DRAWING <br /> CIRCUITS CAPACITY IN ALMOST ALL CASES AND CURRENT CANNOT BE USED AS PACKAGE.PLEASE CONTACT CONVERGINT ENGINEERING DEPARTMENT WITH ANY <br /> THE ONLY CIRCUIT WIRING LIMITATION.ALTERATIONS TO CIRCUIT LENGTH QUESTIONS ON THE APPLICATION OF SURVIVABILITY. <br /> FROM THOSE CALCULATED MAY CAUSE CIRCUITS TO BE OUT OF THE <br /> TOLERANCES GRANTED BY THE FIRE ALARM CODE.CHANGES TO DEVICE IN-BUILDING FIRE EMERGENCY VOICE/ALARM COMMUNICATIONS SHALL BE <br /> LOCATION OR CIRCUIT LENGTH SHALL BE COMMUNICATED TO THE CONVERGINT SURVIVABLE BASED ON ONE OF TWO CATEGORIES(24.3.6.4) <br /> TEAM. •• FOR SYSTEMS EMPLOYING RELOCATION OR PARTIAL EVACUATION,A LEVEL <br /> 2 OR 3 PATHWAY SURVIVABILITY SHALL BE REQUIRED(24.3.6.4.1). <br /> NAC CIRCUIT WIRING AND ROUTING MUST NOT EXCEED WHAT IS SHOWN ON THE •• FOR SYSTEMS THAT DO NOT EMPLOY RELOCATION OR PARTIAL <br /> DESIGN DRAWINGS AND CALCULATIONS.A VOLTAGE DROP TEST IS PART OF EVACUATION,A LEVEL 0,LEVEL 1,LEVEL 2 OR LEVEL 3 PATHWAY <br /> MOST FIRE FINALS AND IS REQUIRED BY NFPA.A FAILED FIRE FINAL MAY SURVIVABILITY SHALL BE REQUIRED(24.3.6.4.2). <br /> REQUIRE REWIRING OF THE FAILED CIRCUITS. <br /> TWO-WAY IN-BUILDING WIRED EMERGENCY COMMUNICATIONS SYSTEMS SHALL <br /> WIRE RESISTANCE RATINGS USED FOR CALCULATIONS: HAVE A PATHWAY SURVIVABILITY OF LEVEL 2 OR LEVEL 3(24.3.6.7).THIS <br /> 18AWG-13 OHMS PER 1000' APPLIES TO FIREMAN PHONE SYSTEMS,STAIRWELL RE-ENTRY INTERCOM <br /> i6AWG-8 OHMS PER 1000' AND ELEVATOR LOBBY TWO-WAY AS REQUIRED BY INTERNATIONAL BUILDING <br /> 14AWG-:OHMS <br /> PER 1000' CODE(IBC),SECTIONS,403 AND 1009.8. <br /> EXAMPLE: 1.0 AMP CIRCUIT LOAD USING#14 WIRE=409 FEET MAXIMUM. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS(DAS)SHALL <br /> COMPLY WITH 24.3.6.8.1 THROUGH 24.3.6.8.4.DAB IS NOT A COMPONENT OF <br /> THE FIRE ALARM DESIGN AND IS PROVIDED FOR INFORMATIONAL PURPOSES <br /> ONLY. <br /> CLASS A OR B NOTIFICATION WIRING • AREA OF REFUGE EMERGENCY COMMUNICATIONS SYSTEMS SHALL HAVE <br /> PATHWAY SURVIVABILITY OF LEVEL 2 OR LEVEL 3(24.3.6.9.1). <br /> CIRCUITS INTENDED TO TRANSMIT OFF-PREMISES SHALL HAVE A PATHWAY <br /> SURVIVABILITY OF LEVEL 0,LEVEL 1,LEVEL 2 OR LEVEL 3(24.3.6.9.2). <br /> EOL <br /> FOR SMOKE CONTROL SPECIFIC SURVIVABILITY REQUIREMENTS,REFER TO THE <br /> FACP SMOKE CONTROL SECTION OF OUR NOTES.UPON REQUEST,CONVERGINT WILL <br /> OR EOL RESISTOR ON PROVIDE EQUIVALENT SUBSTITUTIONS FOR ANY SPECIFIED CABLE.ANY CABLE <br /> NAC NON ADDRESSABLE SUBSTITUTED MUST HAVE EQUAL TO OR BETTER PROPERTIES TO THE CABLE <br /> CIRCUITS SPECIFIED IN OUR WIRE LEGEND. <br /> DEVICE DEVICE POWER REQUIREMENTS <br /> CLASS B,STYLE 4 WIRING EACH MAIN FIRE ALARM PANEL REQUIRES(1)120VAC,20AMP DEDICATED <br /> CIRCUIT. <br /> EACH NAC BOOSTER PANEL REQUIRES(1)120VAC,15AMP DEDICATED CIRCUIT. <br /> IN BUILDINGS EMPLOYING EMERGENCY STANDBY POWER SYSTEMS,THE FIRE REIJON-DESCRIPTION - <br /> ALARM SHALL BE SUPPLIED WITH EMERGENCY POWER.THIS IS REQUIRED IN ISSUEDFOR PERMIT 12-1-24 TH <br /> FACP HIGH-RISE AND SMOKE CONTROL APPLICATIONS.ALL OTHER APPLICATIONS I ENGINEERING REVISIONS 02-5 TIN <br /> OR ARE SUBJECT TO LOCAL BUILDING AND ELECTRICAL CODES. <br /> NAC <br /> WHERE THE FIRE ALARM SYSTEM IS CONNECTED TO EMERGENCY <br /> POWER,THE FIRE ALARM SYSTEM MONITORS THE GENERATOR FOR T2 <br /> RUNNING,FUEL LOW AND TROUBLE STATES. <br /> DEVICE DEVICE FOR ADDITIONAL DETAILS,REFER TO NFPA 72,CHAPTER 10. <br /> } <br /> a <br /> O 1116 <br /> TAYLOR H. <br /> 0 PROJECT DESIGNER: gnORH <br /> W <br /> Q CLASS A.STYLE 6 WIRING <br /> U <br /> to <br /> Q SEPARATION OF CLASS A CIRCUITS-INSTALLATION EXCEPTIONS: <br /> PROVIDENCE PACIFIC <br /> H CLASS A OUTGOING AND RETURN CONDUCTORS,EXITING AND RETURNING LEVEL 2 BEHAVIORAL HEALTH <br /> TO THE CONTROL PANEL,ARE TO BE ROUTED SEPARATELY.THE MINIMUM 916 PACIFIC AVE <br /> N 7 RECOMMENDED SEPARATION IS 1 FT.VERTICALLY AND 4 FT. <br /> x HORIZONTALLY.THE FOLLOWING EXCEPTIONS STILL DO NOT ELIMINATE A 98201 <br /> o THE 2ND PAIR OF WIRES.THEY ALLOW YOU TO USE A SINGLE RACEWAY <br /> M AND ELIMINATE THE SEPARATION FOR THESE CONDITIONS. <br /> H <br /> z 1. WHEN MAXIMUM CABLE,ENCLOSURE,OR RACEWAY IS LESS THAN 10 NOTES <br /> FEET.NO LIMIT TO NUMBER OF DEVICES. <br /> 2. UNLIMITED CONDUIT OR RACEWAY DROP TO AN INDIVIDUAL DEVICE. <br /> () <br /> 3. UNLIMITED CONDUIT OR RACEWAY DROP TO A ROOM NOT FIRE ALARM SYSTEM <br /> Z EXCEEDING 1000 SO,FT.NO LIMIT TO THE NUMBER OF DEVICES. <br /> Q wlNc. <br /> o FA-0-2 <br />