GENERAL LEGEND ABBREVIATIONS AIR DISTRIBUTION LEGEND o <br /> SYMBOL DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION DRAWING INDEX = <br /> eA DETAIL SYMBOL A = IDENTIFYING NUMBER ABV ABOVE L LENGTH S i LIGHT LINEWORK INDICATES SHEET NUMBER DESCRIPTION <br /> B B =SHEET WHERE DETAIL IS SHOWN AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE EXISTING DUCT OR EQUIPMENT MOA COVER SHEET,GENERAL NOTES,&INDEX vj <br /> AHU AIR HANDLING UNIT LES POUNDS MO.2 MECHANICAL SPECIFICATIONS aAL ACOUSTIC LINED LF LINEAR FOOT/FEET MO.3 MECHANICAL SCHEDULES Z <br /> DETAIL SYMBOL, A = IDENTIFYING NUMBER AP ACCESS PANEL LVG LEAVING INDICATES DUCT OR EQUIPMENT <br /> A Y "S,iA MIA MECHANICAL FLOOR PLAN-DEMO vi <br /> B =SHEEP WHERE DETAIL IS TAKEN APD AIR PRESSURE DROP LWG LOW WALL GRILLE TO BE REMOVED �V B C ARCH ARCHITECT ARCHITECTURAL LWR LOW WALL REGISTER M2.1 MECHANICAL FLOOR PLAN <br /> C =SHEET WHERE DETAIL IS SHOWN / U N <br /> ARV AUTOMATIC RELIEF VALVE or LWf LEAVING WATER TEMPERATURE 18z12 M3.1 DETAILS rn+_' <br /> ACID RESTISTANT VENT L <br /> ARW ACID RESTISTANT WASTE MAX MAXIMUM �� 18z12 DUCT SIZE IN INCHES <br /> A SECTION SYMBOL: A = IDENTIFYING LETTER FIRST SIZE LISTED IS SIDE SHOWN O i' <br /> B B =SHEET WHERE SECTION IS SHOWN MBH 1000 BRITISH THERMAL m a <br /> BOO BACKDRAFT DAMPER UNITS PER HOUR -c'. <br /> BFP BACKFLOW PREVENTER MCC MOTOR CONTROL CENTER �� ACOUSTIC LINED DUCT ur <br /> BHP BRAKE HORSEPOWER MECH MECHANICAL Ez <br /> BG BELOW GROUND MFR MANUFACTURER LLB§ <br /> A SECTION SYMBOL: A = IDENTIFYING LETTER BJ BETWEEN JOISTS MIN MINIMUM R I--,--,� Ozg;:; <br /> B =SHEET WHERE SECTION IS TAKEN BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS Ski I~I R DUCT OFFSET(UP)IN DIRECTION OF ARROW Uw <br /> B C C =SHEET WHERE SECTION IS SHOWN BTUH BRITISH THERMAL UNITS PER HOUR MTD MOUNTED (NOT TYPICALLY SHOWN) EI <br /> MTG MOUNTING I-,--,� <br /> CC COOUNGACOIL N/A NOT APPLICABLE �}—�� I~I D DUCT OFFSET(DN)IN DIRECTION OF ARROW GENERAL MECHANICAL NOTES <br /> SECTION CUT LINE INDICATOR CD CEILING DIFFUSER N/C NORMALLY CLOSED (NOT TYPICALLY SHOWN) <br /> CFM CUBIC FEET PER MINUTE N/O NORMALLY OPEN CEILING NTS NOT TO SCALE 1. CONTRACTOR SHALL SECURE,MAINTAIN,AND PAY FOR ALL REQUIRED PERMITS,LICENSES,AND 2727 Oakes Ave. <br /> CG CEILING GRILLE NC NOISE CRITERIA 18'i ROUND DUCT IN INCHES INSPECTIONS FOR DURATION OF WORK UNLESS DIRECTED OTHERWISE. Suite 100 <br /> CI CAST IRON NIC NOT IN CONTRACT �� 18'i <br /> O KEYED REFERENCE NOTE OR SHEET NOTE C. Everett,WA 98201 <br /> CO CLEANOUT 1802"0 2. MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2021 <br /> POINT OF CONNECTION(POC)SYMBOL CONC CONCRETE OA OUTSIDE AIR �� 18z12'Y OVAL DUCT IN INCHES EDITIONS OF THE INTERNATIONAL MECHANICAL CODE,WASHINGTON STATE ENERGY CODE, REVISIONS <br /> CONN CONNECT or CONNECTION OBD OPPOSED BLADE DAMPER INTERNATIONAL BUILDING CODE,INTERNATIONAL FIRE CODE,UNIFORM PLUMBING CODE,AND <br /> P1-1 PLUMBING FIXTURE REFERENCE(REFER TO SCHEDULE) CONST CONSTRUCTION O/C ON CENTER GOVERNING STATE AND LOCAL CODES AND ORDINANCES. <br /> CONT CONTINUATION OD OUTSIDE DIAMETER 18.10 18z12 CHANGE OF DUCT SIZE 3. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH <br /> AHU-1 EQUIPMENT IDENTIFICATION(REFER TO SCHEDULES) CR CONDENSATE RETURN OPNG OPENING MAY BE REQUIRED. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND IS <br /> OA MEDICAL GAS OUTLET IDENTIFICATION(REFER TO SCHEDULE) DB D or DRY BULB PRESSURE CONTROL VALVE 5�18z12 TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. <br /> CHANGE OF DUCT SIZE(TRIANGLE NOT ALWAYS SHOWN) <br /> DIA <br /> DI DIAMETER PH or 4 PHASE DIRECTIRECT RD 18z10 DIGITAL CONTROL PD PRESSURE DROP 4. ALL WORK SHALL COMPLY WITH THE OWNER'S REQUIREMENTS. <br /> MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL DIM DIMENSION PLCS PLACES �® RECTANGULAR SUPPLY DUCT ELBOW TURNED UP 5. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE COMPLETE <br /> ON DOWN POC POINT OF CONNECTION <br /> DPR DAMPER POUA POINT OF USE ALARM RESPONSIBILITY OF THE CONTRACTOR.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY <br /> DWG DRAWING PRV PRESSURE REDUCING VALVE DESIGN CHANGES A IMPACTS THAT THE PROPOSED EQUIPMENT SUBSTITUTION HAS ON OTHER <br /> MEDICAL GAS ALARM PANEL MOUNTED IN WALL DISCIPLINES. ANY ADDITIONAL ELECTRICAL,STRUCTURAL,MECHANICAL,OR ARCHITECTURAL <br /> PSI POUNDS PER SQUARE INCH �® RECTANGULAR SUPPLY DUCT ELBOW <br /> E-100 EXHAUST AIR REQUIREMENTS SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO THE OWNER. <br /> PSIG POUNDS PER SQUARE INCH GAGE TURNED DOWN OR AWAY <br /> NUMBER INDICATES CFM QUANTITY .�1�W <br /> MEDICAL GAS OUTLET 6. PLANS AND SPECIFICATIONS SHALL BE TAKEN TOGETHER. PROVIDE ALL WORK CALLED FOR IN -� OF A <br /> EA EACH R-100 RETURN AIR EITHER.IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND PLANS THE MORE STRINGENT <br /> EAT ENTERING AIR TEMPERATURE NUMBER INDICATES CFM QUANTITY �� RECTANGULAR RETURN/EXHAUST DUCT ELBOW TURNED UP SHALL APPLY. FT <br /> EF EXHAUST FAN RA RETURN AIR <br /> 1 EG EXHAUST GRILLE RAG RETURN AIR GRILLE 7. ALL EQUIPMENT AND MATERIAL ON THE JOB SITE PRIOR TO INSTALLATION SHALL BE COVERED <br /> REVISION CLOUD AND REVISION NUMBER ELEC ELECTRIC or ELECTRICAL REQD REQUIRED AND PROTECTED FROM DIRT,DUST,AND DAMAGE. §sy4t <br /> ELEV ELEVATION RPBP REDUCED PRESSURE BACKFLOW RECTANGULAR RETURN/EXHAUST DUCT ELBOW rsr�® <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM PREVENTOR TURNED DOWN OR AWAY 8. PROVIDE ALL DEMOLITION WORK CALLED FOR OR REQUIRED BY THE INSTALLATION. REMOVE J gfi <br /> ESP EXTERNAL STATIC PRESSURE QYAL <br /> XX BINARY(YES/NO)SENSING SWITCH EWT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE ALL EXISTING EQUIPMENT AND MATERIALS NOT REUSED UNLESS SPECIFIED OTHERWISE BY THE <br /> `r ] SMALL RECTANGULAR DUCT ELBOW OWNER'S REP. 8122124 <br /> (PIPE OR DUCE MOUNTED) IXH EXHAUST TURNED DOWN OR AWAY <br /> IXST or(O EXISTING S-100 SUPPLY AIR ROUND DUCT ELBOW TURNED UP <br /> NUMBER INDICATES CFM QUANTITY QQ'''�� 9. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE <br /> XX BINARY(YES/NO)SENSING SWITCH F FAHRENHEIT SA SUPPLY AIR (J�7 MET. COORDINATE FINAL EQUIPMENT LOCATIONS W/GENERAL CONTRACTOR AND OTHER <br /> (SURFACE MOUNTED) FA FACE AREA SF SUPPLY FAN TRADES TO ALLOW FOR REQUIRED MECHANICAL EQUIPMENT CLEARANCES. <br /> FCO FLOOR CLEANOUT SHi SHEEP <br /> FCU FAN COIL UNIT SIM SIMILAR 10. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL Q <br /> XX ANALOG SENSING DEVICE SP STATIC PRESSURE ROUND DUCT ELBOW TURNED DOWN OR AWAY ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. <br /> (PIPE OR DUCT MOUNTED) FDPR FIRE DAMPEID FRIR SO SQUARE J <br /> FFD FUNNEL FLOOR DRAIN SO FT SQUARE FOOT/FEET 11. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF INSTALLATION STANDARDS AND <br /> ANALOG SENSING DEVICE FF FINAL FILTER SS STAINLESS STEEL CONSTRUCTION CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING <br /> XX (SURFACE MOUNTED) FLR FLOOR STD STANDARD END OF DUCT WITH CAP(UNLESS INDICATED OTHERWISE) CONDITIONS PRIOR TO SHOP FABRICATION AND/OR FIELD INSTALLATION.DISCREPANCIES O Q <br /> FPM FEET PER MINUTE THK THICK BETWEEN EXISTING CONDITIONS AND THE CONSTRUCTION DRAWINGS SHALL BE CALLED THE V <br /> © ANALOG SENSING DEVICE(SURFACE MOUNTED) FPS FEET PER SECOND ATTENTION OF THE ENGINEER. WORK DONE WITHOUT THE ENGINEERS APPROVAL IS THE <br /> TP TRAP PRIMER or TEST PLUG RESPONSIBILITY OF THE CONTRACTOR. Li <br /> FOR MEASURED FLUID) FT FOOT/FEET TYR TYPICAL �yyyyyy�ly FLEX FLEXIBLE DUCT <br /> SUBSCRIPT LETTER(X)INDICATES: FV FACE VELVELOCITYTU TERMINAL UNIT 12. ALL MECHANICAL EQUIPMENT,MATERIALS,AND INSTALLATION SHALL BE PROVIDED BY THE <br /> A-ALARM PRESSURE SENSOR D DIFFERENTIAL PRESSURE GA GAGE or GAUGE UBC UNIFORM BUILDING CODE CONTRACTOR. ALL EQUIPMENT SHALL BE COMPLETE,INSTALLED,AND FULLY FUNCTIONAL <br /> - <br /> F-FLOW RATE GALLV GALLON IZQ <br /> GAL UFC UNIFORM FIRE CODE ® AD DUCE ACCESS DOOR PRIOR TO FINAL ACCEPTANCE OF THE WORK. <br /> H-HUMIDITY GPH GALLONS PER HOUR UMC UNIFORM MECHANICAL CODE 13. INSTALL ALL EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS AND REQUIREMENTS.ANY v_ <br /> L-LOW LIMIT GPM GALLONS PER MINUTE UPC UNIFORM PLUMBING CODE CONFLICTS BETWEEN THE MANUFACTURERS DOCUMENTATION AND THE CONTRACT DOCUMENTS <br /> P-PRESSURE(STATIC) UG UNDERGROUND L VD VOLUME DAMPER SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. LL <br /> T-TEMPERATURE H HEIGHT UH UNIT HEATER O <br /> V-VELOCITY&VOLUME FLOW RATE HD HEAD 14. DO NOT ALLOW ANY WORK TO BE COVERED UP OR ENCLOSED UNTIL INSPECTED,TESTED AND ( 1 <br /> HP HORSEPOWER VA VALVE APPROVED BY OWNER'S REPRESENTATIVE OR AUTHORITY HAVING JURISDICTION. \J <br /> HTG HEATING VAC VACUUM <br /> WAC HEATING,VENTILATION AND VAV VARIABLE AIR VOLUME 15. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. <br /> AIR CONDITIONING VD VOLUME DAMPER <br /> HWG HIGH WALL GRILLE VEL VELOCITY L_L_ <br /> HWR HIGH WALL REGISTER VQ VARIABLE FREQUENCY DRIVE = a <br /> DUCT FITTING REQUIREMENTS Hz HERTZ VfR VENT THRU ROOF W LIJID INSIDE z <br /> ENGINEER'S W WIDE <br /> THE WAPPROVAL FORNG DUCT NGS OTHEREFITTINGCONSIDERED <br /> PRIOR TO FABRICATION.CONLY�FITTINGS WITH DETAIN <br /> QUAL OR IE INVERT ELEVA71ON W/o WITHOUT INSULATION REQUIREMENTS <br /> LOWER PRESSURE DROP WILL BE CONSIDERED. IN INCH or INCHES W � � =o <br /> B WET BULB Z <br /> INSUL INSULATION m' <br /> DUCT ELBOWS OFFSETS WCO WALL CLEANOUT WATERWG E IL <br /> NOTE: OFFSETS(TO AVOID OBSTRUCTIONS)ARE KILOWATT WGE WASTE GASEVACUATION 1.DUCT INSULATION REQUIREMENTS: Lim Q <br /> REQUIRED BUT ARE NOT NECESSARILY SHOWN KW KWH KILOWATT HOUR WPD WATER PRESSURE DROP w <br /> SUPPLY DUCTS: R-3.3 INSULATION FOR ALL SUPPLY DUCTS WITHIN THE BUILDING ENVELOPE.R-8 _ <br /> W ON THE PLANS. WT WEIGHT INSULATION FOR OUTDOOR DUCTS OR DUCTS WITH OUTDOOR AIR.R-6 FOR DUCTS IN \ <br /> �� UNCONDITIONED SPACES. / O °d <br /> r> <br /> DU S W/AIR VELOCITY 15 RETURN DUCTS(ALL DUCTS TRAVELING FROM SPACE BACK TO AN AIR HANDLER):R-8 INSULATION O O iJ <br /> UNDER 1,500 FPM FOR OUTDOOR DUCTS AND R-6 FOR DUCTS IN UNCONDITIONED SPACES.6 ' <br /> DUCTS W/AIR VELOCITY ALL EXTERIOR DUCTS TO BE CLAD WITH ALUMINUM. J JJ <br /> OVER 1,500 FPM AND LL w <br /> ALL DUCTS UPSTREAM OF <br /> TERMINAL UNITS <br /> 46 OR 90' Boa.NI. 242095 <br /> RADIUS ELBOWS <br /> BRANCH DUCT TAKEOFFS oenwH er OEI <br /> ON BOTTOMCESS OF DUCT W/MINIMUM PRESSURE DROP DUCT CONSTRUCTION AND SEALING REQUIREMENTS <br /> UPSTREAM OF TURNING OBTAIN PRIOR APPROVAL FOR ALL RRECTMGULAR vHE«eo eY ON <br /> VANES.REQUIRED FOR RETURN&EXHAUST LOCATIONS DUCT <br /> RETURN AND EXHAUST DUCTS N45' CONICAL 1.SUPPLY DUCTWORK FROM AIR HANDLER TO TERMINAL UNITS <br /> TURNING VANESSPIN-IN PERMIT SET <br /> ---ACCESS ) <br /> TURNING VANES 2"STATIC PRESSURE CLASS WITH ALL TRANSVERSE JOINTS,LONGITUDINAL SEAMS,AND DUCT WALL <br /> �ACCESS PANEL TYPICAL ROUND DUCT <br /> ( OK ONLY RUNOUT TO SINGE PENETRATIONS SEALED(SMACNA SEAL CUSS A). 08/22/24 <br /> CHANGE OF DUCT SIZE REQUIRED FOR RETURN RECTANGULAR UNDER DIFFUSER OR <br /> &EXHAUST DUCTS 1.500 FPM GRILLE ONLY 2.SUPPLY DUCTWORK DOWNSTREAM OF TERMINAL UNITS: <br /> V STATIC PRESSURE CLASS WITH ALL TRANSVERSE JOINTS,LONGITUDINAL SEAMS,AND DUCT WALL COVER SHEET <br /> MAX. IF PENETRATIONS SEALED(SMACNA SEAL CLASS A). SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL AND GENERAL <br /> FFD= DUCTWORK DO NOT REQUIRE SEALING. <br /> TRANSITION NOT LESS THAN TWICE THE DUCT AREARE THAN 2W,BUT F12T 3.EXHAUST AND RETURN DUCTWORK: INFO <br /> /3W OK IF <br /> CONICAL SPIN-IN OR DER 3,000 FPM) 2"STATIC PRESSURE CLASS WITH ALL TRANSVERSE JOINTS,LONGITUDINAL SEAMS,AND DUCT WALL <br /> TRANSITION TO CONNECTION W I~ PENETRATIONS SEALED(SMACNA SEAL CLASS A). 1'PRESSURE CLASS ACCEPTABLE BETWEEN <br /> SIZE AT LEAST 50%GREATER GRILLES AND FIRST DAMPER. <br /> THAN AREA OF SMALLER <br /> DUCT <br /> END TAP w .0 <br /> . 1 <br />