K ENGINEERS INC. <br /> 208 Thlyd Street <br /> Lyndon,WA. 98264 W <br /> BUS. (360) 354-4757 = <br /> BASEMENT LEVEL MAIN FLOOR FIRST FLOOR SECOND FLOOR FAX (360) 354-6794 <br /> i(n <br /> W� <br /> _ _ <br /> rn <br /> SWBD 4NBD 4NB J4 4NM J4 4N1 C3 T2N2S F3 2N2S L <br /> 200/3 <br /> 480/2]]V 31600 A 4W MPS �` 480:120/240V L <br /> 65,000 AIC 200/3SPACE 3].5KVA m Q <br /> 40013 SPACE <br /> _ 2N2C <br /> 40013 SPACE 1600/3 <br /> 27,354 4 <br /> 400/3SPACE 17,351 <br /> �� TO PANEL 2NB 2N2B <br /> �R 400/3 <br /> 100/3SPACE J4 J4 <br /> GF = 225/3 2N2A <br /> 5 Iqq 100/3SPACE TO EXIST SWBD <br /> 1600/3 100/3 SPACE 800/9 <br /> GF <br /> 4o0/3 SPACE2727 Oakes Ave. <br /> 0/3 <br /> 2 P3 5 N4 400/3SPACE Suite 100 <br /> 5 TNi <br /> Everett,WA 98201 <br /> 480V20BY/120V 200/3 SPACE <br /> PAD MOUNTED UTILITY GF 2 P4 500WA SWBD 2NBD — REVISIONS <br /> TRANSFORMER t TO MCCN1 1600 AMPS 200/3 SPACE <br /> 80013 208/120V,3,4W _ <br /> NORMAL SERVICE 22,000 AIC <br /> 480V/277V,3 4W 200/3 SPACE <br /> FROM SNOHOMISH GF <br /> COUNTY PUD <br /> 46,100 RMS 1600/3 SPACE <br /> M <br /> KHM GF <br /> GF <br /> 1600/3 SPACE <br /> 4000/3 GF <br /> 1200/3 SPACE <br /> (8)4#750 KCMIL CU SWBDM <br /> 4000 AMPS R I <br /> 480/2765,000 AIC GF v��pF WA cA�N <br /> 1200/3 SPACE <br /> T <br /> 3y /N zm <br /> 4d,23] 41794 <br /> GF (<3 <br /> 800/3 SPACE IONAL�Ol <br /> GF <br /> 800/3 SPACE <br /> GF 4VM F4 4V1 F4 4V2 <br /> 800/3 SPACE SWBD 4YBD O }� <br /> CRITICAL BRANCH <br /> 1 AMPS <br /> GF 480/27 65,W,3 4W <br /> fi5,000 AIC 2 J3 <br /> 800/3 SPACE TO PANEL 2NBD cu <br /> 450/9 <br /> J4 F4 <br /> GF 00 <br /> 3 qq T <br /> 1200/3 400/3SPACE y <br /> GF 40013 SPACE <br /> 2 pq _ U _ <br /> 800/3 40013 SPACE <br /> GF 20013 SPACE <br /> CO <br /> 3 Q4 Lee1200/3 20013 SPACE • O <br /> 20013 SPACE ('J� <br /> 37,d31 `V <br /> 1200/3 4A480/27]VPNELCRIPTION • O <br /> 2-208Y/120V <br /> ATS#8Y 3 Q4 N-NOR <br /> CRITICAL BRANCH X-LIFE SAFETY BRANCH <br /> 1200 AMPS,4 POLE, V-CRITICAL BRANCH (D <br /> BYPASS/ISOLATION W-EQUIPMENTBRANCH W /ems <br /> 65,000 AIC B-2-FLOOR DESIGNATION W <br /> 0 in <br /> 3 qq FEEDER SCHEDULECIS <br /> ATS#9X [L■ <br /> LIFE SAFETY FEEDER COPPER CONDUCTORS <br /> 800 AMP,4 POLE NO. RACEWAY CONDUCTORS � u, <br /> BYPASS/ISOLATION O <br /> 65,000 AIC Aq 7" 4-#6 <br /> A3 3/4" 3-4e Lee <br /> BOOB <br /> SWBD EG B4 ill 4 #6 > O <br /> 2500 AMPS 2 P4 TO SWBD 2XBD B3 1' 3-#6 O O O <br /> d8012]]V,3,4W C4 11/4" 4-#4 <br /> fi5,000 AIC �� ATS#10W 225�\3 <br /> EQUIPMENT BRANCH D4 4X8 D4 4X1 C3 7" 3-#4 _ <br /> 1200/3 65,DAMP,4 POLE 10013 <br /> 65,000 AIC SWBD 4XBD 04 11/4" 4-#2 <br /> 800/3 D3 11/4" 3-#2 u <br /> 3 qq TO SWBD 4WBD LIFE SAFETY 800 AMPS 200/3SPACE <br /> 80,AMPS E4 11/2" 4-#1 <br /> DIESEL EMERGENCY GENERATORS 1200/3 4802]65,3,4W 200/3 SPACE E3 11/4" 3-9 1 <br /> STANDBY RATED 65,000 AIC - <br /> 600KW1]25KVA(600.83 p( 225/3 SPACE F4 2" 4-41/0 <br /> 480Y/27N,3PH,4W 200/3 roe.rvo. <br /> 350/3� 34,882 G 112" 3-#1/0 2876 <br /> _ 100/3SPACE 4 2" 4-#2/0 <br /> 35013 100/3SPACE G3 112" 3-#2/0 ow' 6r KL <br /> 3 P4 ' ^ H4 2" 4-#310 <br /> 400/33SS APACE cHECxED er <br /> 100/3 SPACE <br /> EG �� 400/3SPACE J4 2"12" 4-#4/0 <br /> SD <br /> 000/3 <br /> 400/3SPACE J3 4-#4/0 <br /> 212" <br /> GEN#1 3 P4 K4 212" 4-250 KCMIL PERMIT SET <br /> 400/3 SPACE K3 212" 3-250 KCMIL <br /> L4 3" 4-300 KCMIL S-2$-2024 <br /> EG �� 200/33`PACE <br /> 1000/3 L3 212" 3-300 KCMIL <br /> 20013 SPACE M4 3" 4-350 KCMIL <br /> GEN#2 - ELECTRICAL - <br /> 200/3SPACE M3 212" 3-350 KCMIL <br /> 20013 SPACE N3 3" 3-400 KCMIL PARTIAL POWER <br /> TOTALIZER i <br /> BOARD 100/3SPACE P4 312" 4-500KCMIL SYSTEM RISER <br /> KCMIL <br /> 100/3SPACE Q4 312" 4-BOO KCMIL DIAGRAM <br /> 03 3" 3-600 KCMIL <br /> 100/3 SPACE <br /> NOTE:SIZES BASED ON THW WIRE <br /> PARTIAL POWER SYSTEM RISER DIAGRAM E 6.1 <br /> NO SCALE <br />