Laserfiche WebLink
BUILDING CODE 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND <br /> 2018 INTERNATIONAL BUILDING CODE NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. S D <br /> FLOOR LOAD G. PROVIDE 3"x3"x0.229" WASHERS AT ALL ANCHOR BOLTS. A F <br /> DEAD LOAD : 12 psf 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS <br /> LIVE LOAD: 40 psf I # I G" UNLESS NOTED OTHERWISE. LAG BOLT PILOT HOLES U) <br /> SHALL BE PRE-DRILLED TO GO% OF THE NOMINAL DIAMETER OF C N <br /> ROOF LOAD <br /> THE LAG BOLT UNLESS NOTED OTHERWISE. p <br /> DEAD LOAD: 15 psf <br /> FLAT ROOF SNOW LOAD: 135p5f 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 0 <br /> SNOW EXPOSURE FACTOR (Ce): 1 . 1 5#8" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM OF J U) <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1 .0 48" ON CENTER. BOLTS MUST BE EMBEDDED A MINIMUM OF 7" B Q �'o N <br /> THERMAL FACTOR (Ct): I . I INTO CONCRETE OR MASONRY. SEE PLANS AND DETAILS a� o <br /> FOR 00 <br /> W PO <br /> REQUIREMENTS WHERE APPLICABLE. <br /> WIND DESIGN DATA 'U) y3 <br /> I . BASIC WIND SPEED: I 10 MPH 9. RIM JOIST IS TO BE I I #4" LSL MINIMUM. X Nco <br /> 2. WIND IMPORTANCE FACTOR (Iw): 1 .0 M cu <br /> w z <br /> BUILDING CATEGORY: II 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION - 0 <br /> 3. WIND EXPOSURE: C WALLS AND SOLID BLOCKING UNDER PERPENDICULAR PARTITION <br /> a <br /> 4. KA = 1 .37 WALLS. <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA <br /> G c <br /> G. APPLICABLE WIND PRESSURE FOR 1 1 . CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO H L L- <br /> COMPONENTS AND CLADDING: NA THESE DETAILS � <br /> E <br /> SESIMIC DESIGN DATA GENERAL <br /> 1 . SEISMIC IMPORTANCE FACTOR: 1 .0 <br /> •' *. .'ti ' '• =. <br /> 1 . ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE :•a •, <br /> SEISMIC USE GROUP: I ',.. ,• : : . : . •: .,� . ;. , <br /> CONTRACT DRAWINGS. :. . .' ' '4. ' . - • <br /> 2. SPECTRAL RESPONSE ACCELERATION (55): 1 37.9% G •': '. . • .. a • . -- <br /> 3. SITE CLASS: D (ASSUMED) ••' • <br /> 4. SPECTRAL RESPONSE COEFFICIENTS (5D5): 110.3%G 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR ; i. '•.' •. , .a . . ___ <br /> SHALL BE RESPONSIBLE FOR THE 5AFETY OF THE BUILDING. •' <br /> 5. SEISMIC DESIGN CATEGORY: D THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, No. Date By Revision <br /> G. BASIC SEISMIC-FORCE-RESISTING SYSTEM: SHEARWALLS BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, <br /> 7. DESIGN BASE SHEAR: SEE CALCULATIONS ® <br /> STATE AND LOCAL SAFETY ORDINANCES. ANY DEVIATION MUST DOUBLE TOP PLATE W/ EDGE NAILING © HOEDOWN PER SCHEDULE AND <br /> 8. SEISMIC RESPONSE COEFFICIENT (Cs): 0. 17 BE APPROVED PRIOR TO ERECTION. (STAGGER) PLAN (HDQB-SD03 SHOWN) <br /> SHEARWALLS QH COORDINATE ALL STUD AND <br /> 9. RESPONSE MODIFICATION FACTOR (K): G.5 (WOOD © SHEARWALL EDGE NAILING AT ALL PANEL <br /> I O. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA EDGES. BLOCKING AT ALL PANEL EDGES PLATE SIZES w/ SHEARWALL <br /> FORCE PROCEDURE STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA WHERE APPLICABLE. SCHEDULE REQUIREMENTS <br /> PRIOR TO ERECTION. © EDGE NAILING TO HOLDOWN POST (FULL rq <br /> HEIGHT) STAGGER INTO DOUBLE STUDS OJ EDGE NAILING TO POSTS, TRIM 0 <br /> fKAMING LUMBER 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL O STUDS @ 16" ON CENTER STUDS, AND KING STUDS LLI N <br /> LJ I . FRAMING LUMBER SHALL B �E HEM-FIR NO. 2. GRADES CONSTRUCTION PROCEDURES INCLUDING LAGGING, SHORING QE PRESSURE TREATED SILL PLATE WITH BEARING STUD FOR HEADER U > 0 ) <br /> ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS. AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, EDGE NAILING AND ANCHOR BOLTS PER z Q <br /> LUMBER TO BE GRADE MARKED PER WCLIB STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, SHEARWALL SCHEDULE. © RIMJOIST TO BE 1Y2" MIN L,J 0 Q <br /> SPECIFICATIONS. STATE AND LOCAL SAFETY ORDINANCES. ATOP PLATE SPLICE NAILING TO BE (8) 16d THICKNESS AT ALL 0 <br /> SINKERS (MIN). LAP 48" MINIMUM. CENTER SHEARWALLS - z <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SPLICE ON STUD. W <br /> PLYWOOD, EXPOSURE I SHEATHING CONFORMING TO COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK <br /> EITHER COMMERCIAL STANDARDS P5 1 -83, APA PKP- 1 08, ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ry O <br /> OR VOLUNTARY PRODUCT STANDARD P5E-92. PROVIDE A ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE STD . SHEARWALL ELEVATION W RIM W <br /> MINIMUM OF 3/8" EDGE DISTANCE ON ALL NAILS AND %8" <br /> PROCEEDING WITH THE WORK. 1 SCALE: Y2"=1 '-0" z <br /> EXPANSION JOINT BETWEEN ALL PANEL EDGES. MINIMUM G. SHOP DRAWINGS FOR PREFABRICATED TRUSSES AND Q N LW <br /> SHEATHING REQUIREMENTS ARE AS FOLLOWS: MANUFACTURED FLOOR JOISTS SHALL BE SUBMITTED TO THE <br /> ROOF SHEATHING TO BE '9" INT-APA RATED ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br /> PLYWOOD OR 7/ " 05D WITH EXTERIOR GLUE P. <br /> 6 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF w <br /> 40/20. NAIL WITH 8d NAILS AT G" ON CENTER AT CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY G <br /> PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE MEMBERS. INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS <br /> 34 SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED 383 <br /> SUB FLOORING TO BE TONGUE AND GROOVE C-D SUBJECT TO REVIEW BY THE ENGINEER. <br /> QpN� <br /> INT-APA RATED PLYWOOD OR 05B WITH EXTERIOR 8, ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL \ <br /> GLUE, P.I. 48/24. GLUE AND NAIL WITH I Od NAILS OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED JUL O 7 2022 <br /> AT G" ON CENTER AT PANEL EDGES AND 1211 ON <br /> CENTER AT INTERMEDIATE MEMBERS. OUT. <br /> Drawn By. CCC <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9. 1 OF THE 9• COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL Checked By. CCC <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS Date: 06-08-24 <br /> OTHERWISE. USE COMMON NAILS THROUGHOUT UNLESS REQUIRED FOR DUCTS, PIPES, PIPE SLEEVES, ELECTRICAL 9557 <br /> NOTED OTHERWISE. CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE <br /> OR OTHERWISE INCORPORATED IN STRUCTURAL WORK. <br /> 4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED STRUCTURAL <br /> UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING 10. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER NOTES <br /> BY THE STRUCTURAL ENGINEER. STANDARD DETAILS FOR HEATERS, MECHANICAL EQUIPMENT, <br /> VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED MECHANICAL <br /> EQUIPMENT SHALL BE SWAY OK LATERALLY BRACED <br /> S - 1 . 0 <br />