My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2024 Plans 2025-07-02
>
Address Records
>
SEAWAY BLVD
>
3315
>
Plans
>
3315 SEAWAY BLVD 2024 Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 7:30:30 AM
Creation date
6/16/2025 11:17:53 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Permit
M2409-094
Year
2024
Notes
TERRA POWER 2ND FLOOR HVAC MODS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MECHANICAL GENERAL ABBREVIATIONS HVAC GENERAL NOTES-2021 WSEC <br /> L <br /> g ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME m g <br /> AC AIR CONDITIONING UNIT EWT ENTERING WATER TEMPERATURE NONA NOMINAL 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAYBE REQUIRED.THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER <br /> 6`y <br /> ? AFF ABOVE FINISHED FLOOR FCU FAN COIL UNIT TUTS NOT TO SCALE TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. Z 3 E <br /> AHU AIR HANDLING UNIT FD FIRE DAMPER OBD OPPOSED BLADE DAMPER G Q_ ti <br /> AL ALUMINUM FLA FULL LOAD AMPS OD OUTSIDE DIMENSION Z. MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2021 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE,INTERNATIONAL BUILDING C <br /> BAS BUILDING AUTOMATION SYSTEM FOB FLAT ON BOTTOM POC POINT OF CONNECTION CODE,INTERNATIONAL FIRE CODE 2021 WSEC,AND LOCAL CODES AND ORDINANCES. E � m E <br /> g BDD BACK DRAFT DAMPER FOT FLAT ON TOP PRV PRESSURE REDUCING VALVE S. ALL DUCT SIZE ANNOTATIONS REPRESENT ACTUAL OUTSIDE DIMENSIONS OF THE SHEET METAL(UNO).IF APPLICABLE,INTERIOR INSULATION WILL NEED TO BE ACOUNTED FOR J y <br /> g BI BLACK IRON FED FIRE SMOKE DAMPER PVC POLYVINYL CHLORIDE WHEN DETERMINING ACTUAL DUCT FREE AREA.SEE DUCTWORK INSULATION SCHEDULE FOR ADDITIONAL SPACE REQUIRED FOR EXTERIOR(WRAP)INSULATION. Q N <br /> .W BOD BOTTOM OF DUCT GALV GALVANIZED REQ'D REQUIRED o <br /> BOUT BOTTOM GC GENERAL CONTRACTOR RPBA REDUCED PRESSURE BACKFLOW ASSV " <br /> h 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2021 IMC AND WITH CURRENT SMACNA STANDARDS.EARTHQUAKE BRACE ALL DUCTS 28DIA AND }BTU BRITISH THERMAL UNITS GEN% GENERATOR EXHAUST RTU ROOFTOP UNIT yM <br /> $ BTUH BRITISH THERMAL UNITS PER HOUR GLVNL GALVANNEAL SA SUPPLY AIR LARGER WHICH ARE SUSPENDED MORE THAN 12"BELOW STRUCTURAL SYSTEM. Q <br /> CATI CATEGORY ONE VENT GPM GALLONS PER MINUTE SO SMOKE DAMPER 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS,PER 2021 WASHINGTON STATE ENERGY CODE,COMMERCIAL PROVISIONS.SEE DUCTWORK INSULATION SCHEDULE. 0 Q J m N <br /> CAT4 CATEGORY FOURVENT GREASE GREASE DUCT SL SOUND LINED 1 <br /> CFM CUBIC FEET PER MINUTE GWB GYPSUM WALL BOARD $M SHEET METAL U U c <br /> CPVC CPVC MATERIAL HP HORSE POWER,HEAT PUMP SP STATIC PRESSURE -ACOUSTICAL SOUND LINING,WHERE INDICATED,SHALL BE 1"1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM. co <br /> IDS DUCTBOARD HVAC HEATING,VENTILATION AND AIR COND. SS STAINLESS STEEL LL w <br /> LL DOC DIRECT DIGITAL CONTROLS Hx HEAT EXCHANGER SUSP SUSPENDED 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER,1 112"FIBERGLASS INSULATION,AND NON-PERFORATED INTERIOR LINER WITH WIRE HELIX.DUCT SHALL BE A ^n <br /> p DEMO DEMOLISH ID INSIDE DIMENSION T THERMOSTAT UL 181 LISTED CLASS 1 AIR DUCT.FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12'IN LENGTH UNLESS NOTED OTHERWISE. <br /> 6 DP DIFFERENTIAL PRESSURE LAT LEAVING AIR TEMPERATURE TOD TOP OF DUCT <br /> DPM DIFFERENTIAL PRESSURE MONITOR LBS POUNDS TV TURNINGVANES <br /> DIFF DIFFUSER LWT LEAVING WATER TEMPERATURE TYP TYPICAL 7. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE,RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER.RECORD DRAWINGS <br /> R DMPR DAMPER MAT MIXED AIR TEMPERATURE UNO UNLESS NOTED OTHERWISE SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT,GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, <br /> DN DOWN NIGH ONE THOUSAND STUN VAV VARIABLE AIR VOLUME INCLUDING SIZES,AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. <br /> E EXISTING MCA MINIMUM CIRCUIT AMPACITY VD VOLUME DAMPER M. <br /> EAT ENTERING AIR TEMPERATURE MD MOTORIZED DAMPER VFD VARIABLE FREQUENCY DRIVE <br /> EC EGGCRATE MIN MINIMUM W DUCT INSULATION WRAP 8. MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL BE LISTED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A <br /> EER ENERGY EFFICIENCY RATIO M-M MACDONALD-MILLER WI WITH SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723,EXCEPT AS NOTED IN SECTION 602.2.1 OF THE 2021 IMC. <br /> EF EXHAUST FAN NC NORMALLYCLO$ED WELD WELDED <br /> ELEV ELEVATION NIC NOT IN CONTRACT 0 VOLTAGE PHASE&DUCT DIAMETER <br /> ESP EXTERNAL STATIC PRESSURE NO NORMALLYOPEN 9. ALL MECHANICAL WORK SHOWN ON DRAWINGS INTENDED TO BE INSTALLED SOLELY BY MACDONALD-MILLER FACILITY SOLUTIONS.MACDONALD-MILLER FACILITY SOLUTIONS „ <br /> SHALL NOT BE HELD ACCOUNTABLE FOR ANY DESIGN OR CONSTRUCTION DEFICIENCIES IF WORK IS PERFORMED BY AN OUTSIDE PARTY. g� ♦`T <br /> A� B�'ti4 <br /> BBIOWAL`a� <br /> 9/26/2024 <br /> HVAC SYMBOL LEGEND DUCTWORK SCHEDULE <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> WORKING SMACNA SMACNA I I I I I I I <br /> 14x12 SA BARE RECTANGULAR SHEETMETAL ��� ��.,+ RECTANGULAR SIDE WALL GRIUEWITH I WITHOUT OBO SERVICE( PRESSURE PRESSURE SEAL <br /> -14x12 SA-SL-- SWNDUNE SHEEMETAL(GENERALNOTES) ®� SUPPLYDUCTUPNONM <br /> USAGE LOCATION MATERIAL (IN.WC) CLASS(IN.WC) CLASS NOTES <br /> --- LOW PRESSURE SUPPLY AIR FROM TERMINAL UNITS TO GRO'S GALV.STEEL 1 1 B 1 <br /> 1402 SA-W SHEETMETALWIINSUTAnON(GENERAL NOTES) EXHAUSTDUCTUPBOWN FLEXIBLE DUCT CORN TO GRD'$ PREINSUL.FLEX 0.5 RATED a6",-1' NA 2,3 <br /> 12BSA BARE ROUND SHEETMETAL RETURN DUCT UPNOWM NOTES: <br /> 12B SA-W ROUND SHBETMEFALWI INSULATION(GENERAL NOTES) ® SUPPLY AIR TERMINAL RECTANGULAR AND SQUARE 1.SHEET METAL GAUGES AND FITTINGS PER SMACNA AND MACDONALD-MILLER DUCT CONSTRUCTION STANDARDS. <br /> ------ 2.THERMAFLEX"GKM"OR EQUAL,WITH 12 FOOT MAXIMUM LENGTH. <br /> 14x120 SA OVAL SHEETMETAL WI INSULATION(GENERAL NOTES) RETURN AIRTERMINAL RECTANGULAR AND SQUARE 3.INSTALL PER MFG.GUIDELINES AND INSTRUCTIONS. <br /> 14x120 SA-W EXAMPLE OF EXISTING ® EXHAUST AIR TERMINAL RECTANGULAR AND SQUARE <br /> 14X12 SA EXAMPLE OF E%ISnNG SUPPLYAIRSLOT DIFFUSER Z <br /> -»-�-+-• EXAMPLE OF DEMO AENTA'AIRSLOT DIFFUSER O <br /> LEGAL DESCRIPTION w <br /> 1412 SA EXAMPLE OF NEW EXHAUST AIRSLOT DIFFUSER <br /> PARCEL NU MBER:2804 030040 0300 <br /> 14x12 SA EXAMPLE OF FUTURE(NIC) $ POINT OFCONNECTION <br /> LEGAL DESCRIPTION:$EC 03 PNP 28 RGEOOL0T70FSEAWAV CENTERTWOIINTERMIC eSP REC VOL1 PG5181 THRU 183 AF 8970255009&BEING PTNSEfl4 N W <br /> 14x125A-0 EtTOSEOOUALtt BHFETAIETAL CENTERLINE Q <br /> 14x12SA-C CLEANROOMQUALIY DUCTWORK O THERMOSTAT o <br /> 14x12 SA-DB DUCTBCINRD IT FIBERGLASS) © CARBON MONOXIDE SENSOR <br /> p� CONTINUATION OF ROUND DUCT 10 NITROGEN DIOXIDE SENSOR EV CONTACT LIST <br /> CONTINUAnON OF RECTANGULAR DUCT HUMIDIIYSENSOR TITLE NAME COMPANY PHONE NUMBER EMAIL <br /> PROJECT DESIGN ENGINEER MICKEY WOO MACDONALD MILLER 206-768-3842 MICKEY.W00@MACMILLER.COM <br /> AIR FLOW IN SYMBOL O$ OTHERSENSOR PROJECT EXECUTIVE JOE BRUCKER MACDONALD MILLER 206-7684140 JOE.BRUCKER@MACMILLER.COM <br /> AIRFLOW OUTSYMBOL $® SMOIfE DETECTOR SPECIAL PROJECTS COORDINATOR RYAN MILLER MACDONALD MILLER 206-5194378 RYAN.MILLER@MACMILLER.COM F <br /> SHEETMETAL SUPERINTENDENT NATHAN WAAGEN MACDONALD MILLER 206-768.3942 MATHAN.WAAGEN@MACMILLER.COM w <br /> AHU-001 MECHANICAL EQUIPMENT TAG $ ELECTRICAL SWITCH Z <br /> O <br /> O KEYEDNOTE Iq MITERED ELBOW MTH TURNING VANES w <br /> a � <br /> ElACCESB DOORS O DOUBLE NEGATME PRESSSURE a <br /> RATEDFNCLOSURE DOUBLE POIPRESSBIRG DRAWING SHEET INDEX - HVAC <br /> U V FLEX DUCT NEUT NEUTRAL PRESSSUAE NUMBER TITLE <br /> 24. EQUIPMENT FURROUND CONNECTOR O SINGLE NEGATIVE PRESESURE TING 01 SCHEDULES-HVAC <br /> ®24x24 EQUIPMENT FURRECTANGLIARCONNECTOR O SINGLE POSITNEE PRESOKURE TMO.015 SITE PLAN <br /> �o DM2.02 2ND FLOOR PARTIAL DEMO PLAN-HVAC <br /> Lffi LJ VOLUME DAMPER I REMOTE DAMPER PM RENTAL PRESSURE MONITOR TM2.02 2ND FLOOR PARTIAL PLAN-HVAC <br /> OQ RADIAL AIR TERMINAL H DPM SENSOR SYMBOL <br /> MUMM THAR LAY-IN METAL EGGCRATE(REIURWE)N) will, ROOMNRROWARROW <br /> SCOPE OF WORK <br /> DX HEAT PUMP-FAN COIL UNIT SCHEDULE -RELOCATE(1)CEILING DIFFUSER AND(1)CEILING GRILLE <br /> -PROVIDE(3)NEW CEILING DIFFUSERS AND(1)CEILING GRILLE WITH ASSOCIATED DUCWORK PER DRAWINGS <br /> UNIT AREA BLOWER OSA ELECTRICAL HEAT CONTROL WT NOTES .REBALANCE CEILING DIFFUSERS AND GRILLES PER DRAWINGS <br /> NO. SERVED MFR.&MODEL NO. CFM ESP HP RPM CFM VOLTIPH MCA VOLTIPH KW STG LBS -REBALANCE(2)FAN COIL UNITS PER SCHEDULEIDRAWINGS <br /> FCU-2-01 FLOOR2 MITSUBISHI,PEFY-P30NMHU 740 1" 23013 2.45 24V 124 EXISTING <br /> FCU-2-02 FLOOR2 MITSUBISHI,PEFY-P54NMHU 1390 1" 230/3 3.69 24V 157 EXISTING,1 <br /> FCU-2-03 FLOOR2 MITSUBISHI,PEFY-P54NMHU 1490 1' 230/3 3.69 24V 157 EXISTING,1 <br /> FCU-2-04 FLOOR2 MITSUBISHI,PEFY-P36NMHU 880 1" 23013 3.67 24V 153 EXISTING <br /> FCU-2-05 FLOOR2 MITSUBISHI,PEFY-P27NMHU 600 1" 23013 2.13 24V 124 EXISTING <br /> NOTES: <br /> 1.REBALANCE EXISTING UNIT <br /> DIFFUSER/GRILLE SCHEDULE <br /> 7ZE <br /> ANUFACTURER&MODEL SIZE TYPE NOTES <br /> NUMBER //� <br /> IZE <br /> TUS MI AS NOTED T-BAR MOUNT MODULAR CORE DIFFUSER BORDER TYPE 3,WHITE FINISH v)IZE <br /> TUS 5OF AS NOTED T-BAR LAY-IN EGGCRATE(RETURNI B ISTING TO BE REUSED AS NOTED T-BAR MOUNT MODULAR CORE DIFFUSER REBALANCE TO CFM INDICATED C <br /> CFM G <br /> U <br /> OSESSION Q <br /> S - - - - - - > <br /> _ .SOUND _ _ 5 T <br /> US NAVAL 2 <br /> STATION- HWY2 J <br /> EVERETT <br /> Q <br /> _ o <br /> Z N <br /> SITE <br /> 3315 SEAWAY BLVD <br /> EVERETT,WA 98203 III III LLI <br /> 525 5 Lu Of <br /> N <br /> 526 O O>, J U 0 <br /> 527 m <br /> N <br /> W VICINITY MAP � �a � 0 <br /> NO SCALE n/ n/w _> <br /> LU <br /> LLJ Luj�W ��/1 U) <br /> I— �M W /1 vJ <br /> ErvOINEER: LAST REVISED: <br /> M WOO 09-26-24 <br /> CHECKED BY: DATE PLOTTED: <br /> G GRAHAM 09-26-24 <br /> CAD: ISSUE DATE: <br /> F MAMERTO 09-26-24 <br /> RANINGINUISER <br /> DD-3984-72247206-00 <br /> SHEET NUMBER <br /> TM0.01 <br /> E <br />
The URL can be used to link to this page
Your browser does not support the video tag.