Laserfiche WebLink
EDWARDS°Catalog►Power Supplies and Accessories <br /> EmWARDS <br /> S;;7 <br /> LIFE SAFETY � INCIDENT MANAGEMENT <br /> IIIIIIIIIIII <br /> Remote Booster <br /> IIIIIIIIIIIIII 11� 'hl�i�� <br /> 11111111�����►� ;,.,�� <br /> Power Supplieso <br /> BPS6A, BPS10A MEA <br /> 476-91-E <br /> I .r Vol.13 <br /> IIIIIi l,l'.'lilllliillli O <br /> S3424 <br /> 0 <br /> 7300-1657: <br /> 0229 <br /> Overview Standard Features <br /> The Booster Power Supply(BPS)is a UL 864, 10th Edition listed • Allows for reliable filtered and regulated power to be installed <br /> power supply. It is a 24 Vdc filtered-regulated,and supervised where needed <br /> unit that can easily be configured to provide additional notification 0 Cost effective system expansion <br /> appliance circuits(NACs)or auxiliary power for Mass Notification/ • Provides for Genesis and Enhanced Integrity notification ap- <br /> Emergency Communication(MNEC), as well as life safety applica- <br /> pliance synchronization <br /> tions. <br /> The BPS contains the circuitry to monitor and charge internal • Supports coded output operation <br /> or external batteries. Its steel enclosure has room for up to two • Self-restoring overcurrent protection <br /> 10 ampere-hour batteries.The BPS has four Class B(convert- • Multiple signal rates <br /> ible to two Class A)NACs.These can be activated in one or two • Can be cascaded or controlled independently <br /> groups from the BPS's unique dual input circuits. . Easy field configuration <br /> The BPS is available in 6.5 or 10 ampere models. Each output • On-board diagnostic LEDs identify wiring or internal faults <br /> circuit has a capacity of three amperes;total current draw cannot . Standard EDWARDS keyed lockable steel cabinet with re- <br /> exceed the unit's rating. movable door <br /> The BPS meets current UL requirements and is listed under the • 110 and 230 Vac models available <br /> following standards: 0 Accommodates 18 to 12 AWG wire sizes <br /> Standard(CCN) Description <br /> UL864 10th edition(UOM Fire Alarm Systems • Optional tamper switch <br /> UL636(ANET,UEHX7) Holdup Alarm Units and Systems 0 Dual battery charging rates <br /> UL609(AOTX,AOTX7) Local Burglar Alarm Units and Systems <br /> UL365(APAW,APAW7) Police Station Connected Burglar Alarm Units and Systems • Optional earthquake hardening: OSHPD seismic pre-approval <br /> UL1076(APOU,APOU7) Proprietary Burglar Alarm System Units for component Importance Factor 1.5 <br /> UL1610(AMCX) Central Station Alarm Unit <br /> ULC-S527(UOXXC) Control Units,Fire Alarm(Canada) <br /> ULC-S303(AOTX7) Local Burglar Alarm Units and Systems(Canada) <br /> C22.2 No.205 Signaling Equipment(Canada) <br /> Page 1 of 4 DATA SHEET E85005-0125 <br /> Not to be used for installation purposes. Issue 1.2 <br />