My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE PORTABLE 5 JACKSON ELEMENTARY 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE PORTABLE 5 JACKSON ELEMENTARY 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 2:12:51 PM
Creation date
6/16/2025 1:50:18 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Unit
PORTABLE 5
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. Documentation Cabinet -A documentation cabinet labeled "SYSTEM RECORD ❑ ❑ ❑ <br />DOCUMENTS" shall be installed at the system control unit or at another approved <br />location accessible only to authorized personnel. <br />Step 3: Maximum Load Test - Secondary Power PASS FAIL N/A <br />1. Manual Fire Alarm box - While on battery power, initiate an Alarm by pulling the ❑ ❑ ❑ <br />manual fire alarm box located at the FACP. <br />2. 90 Second Alarm Signal - Verify that the remote Central Station has received a fire ❑ ❑ ❑ <br />alarm signal within ninety (90) seconds. Let alarm continue during next step. <br />3. 5 - 15 Minute Test - Let alarm continue for a minimum of 5 minutes for general ❑ ❑ ❑ <br />occupant notification and 15 minutes for voice Evacuation. This is will give enough <br />time to verify operation of all notification appliances throughout the facility. <br />Audible Alarm Notification Appliances: <br />PASS FAIL N/A <br />4. Per Plans - Verify annunciators are installed per approved plans ❑ ❑ ❑ <br />5. Audible Sound - Audible alarms devices must be 15 dBA above normal ambient ❑ ❑ ❑ <br />sound level in all occupiable areas of building. <br />6. Signal Pattern - Audible signal pattern used to notify building occupants of the ❑ ❑ ❑ <br />need to evacuate shall be the standard alarm evacuation signal consisting of a <br />three -pulse temporal pattern. <br />7. Mounting - Wall -mounted appliances shall have their tops above the finished floor ❑ ❑ ❑ <br />at heights of not less than 90 inches and below the finished ceilings at distances of <br />not less than 6 inches. Ceiling -mounted or recessed appliances shall be permitted. <br />8. Combination Audible/Visible - Combination audible/visible appliances shall be <br />installed as per the requirements for a visible alarm notification appliance. <br />9. Environment - Verify that all appliances as listed for the environment that they are <br />located. (walk-in coolers/freezers, etc.) <br />10. Guards/Cover/ Lenses -Appliances subject to mechanical damage shall be suitably <br />protected by a guard, cover, or lenses that is listed for use with the appliance. <br />Visible Alarm Notification Appliances: <br />11. Per Plans - Ensure the cd matches what was indicated on the plans. <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />PASS <br />FAIL <br />N/A <br />❑ <br />❑ <br />❑ <br />Fire Marshal's Office 1425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 <br />4.13.2020 1 Page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.