My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE PORTABLE 5 JACKSON ELEMENTARY 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE PORTABLE 5 JACKSON ELEMENTARY 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 2:12:51 PM
Creation date
6/16/2025 1:50:18 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Unit
PORTABLE 5
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 I 2 I 3 I 4 I 5 <br /> GENERAL NOTES <br /> 1. INSTALLATION TO BE IN ACCORDANCE WITH THE STRUCTURAL DESIGN AND r,„ <br /> CALCULATIONS OF THE STRUCTURAL ENGINEER. <br /> Uu __ <br /> 2. NEW PORTABLE CLASSROOMS ARE TO BE CONNECTED TO THE MAIN FIRE <br /> �y - __ __ _ ALARM SYSTEM. <br /> -"r - - -� - _ _ i 3. RAMP SHALL CONFORM WITH THE WASHINGTON STATE BARRIER FREE DESIGN DYKEMAN <br /> "---__ REQUIREMENTS AND APPLICABLE FEDERAL,STATE AND LOCAL CODES AND <br /> REGULATIONS. <br /> f• - \ 4. PROVIDE AN UNDER FLOOR ACCESS PANEL WITH A MINIMUM CLEAR OPENING ARCHITECTURE + DESIGN <br /> - �� _ WIDTH OF 18 x24.THE OPENING MUST BE COVERED WITH A DOOR OR SCREEN. <br /> '., -- _.._ .- \, `__ _ 5. PROVIDE UNDER FLOOR VENTILATION AT THE RATE OF 1 SQUARE FOOT NET D <br /> D z _ `" FREE AREA FOR EACH 150 SQUARE FEET OF UNDER FLOOR AREA.VENTS ARE <br /> w _ _ TO BE LOCATED TO PROVIDE CROSS VENTILATION,COVER VENTS WITH 114" Lr) <br /> 7 '• `��"" CORROSION RESISTANT WIRE. <br /> EXISTING <br /> c y -_GRASS ¢ __ __ <br /> ''- _ ___ 6. ALL CONSTRUCTION IS SUBJECT TO FIELD INSPECTIONS,CORRECTIONS AND <br /> ��'+ "`--,--. -' FINAL FIELD APPROVAL TOGETHER WITH ISSUANCE OF A CERTIFICATE OF CONSULTANT: <br /> F "-•""- -___ OCCUPANCY PRIOR TO THE BUILDING BEING OCCUPIED. <br /> 7. AN APPROVED SET OF PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES <br /> w DURING CONSTRUCTION. <br /> ti <br /> p 8. PLACE ONE TYPE 2A-10BC FIRE EXTINGUISHER IN EACH PORTABLE.MOUNT AT <br /> w 5'-0"TYP. <br /> MAX.54"AFF AND PLACE ADJACENT TO DOOR. <br /> ,/ 20'-0"MIN. <br /> m r "L ,' 9. ROOF DRAINAGE TO BE VIA ALUMINUM GUTTERS AND(4)DOWNSPOUTS AT EACH <br /> I -•L r BUILDING CORNER.THE DOWNSPOUTS WILL DRAIN TO SPLASH PANS WHICH <br /> w - i ____ / • _-I D WILL DRAIN TO EXISTING DRAINAGE.PROVIDE POSITIVE DRAINAGE AWAY FROM - <br /> / --� _ THE PORTABLE CLASSROOM AND ALL ADJACENT STRUCTURES. <br /> U <br /> i j j 10.PORTABLE CONTRACTOR TO PAINT BUILDING SKIRT TO MATCH EXISTING BASE REGISTRATION STAMPS: <br /> N AND TRIM COLOR. <br /> dI <br /> 11.REMOVE ALL VEGETATION AND ORGANICS FROM BUILDING PAD AREA.BUILDING <br /> 6"CRUSHED ROCK PAD TO EXTEND 24"BEYOND FACE OF BUILDING AND,2"BEYOND FACE OF 6467 REGISTERED <br /> BUILDING PAD TO RAMPS,LANDINGS AND STAIRS.PROVIDE A 8'THICK CRUSHED ROCK BASE. ARC HrtECT <br /> P EXTEND 24"BEYOND___� <br /> P2 FACE OF BUILDING 12.CONTRACTORS TO LOCATE,CAP AND FLAG ALL EXISTING IRRIGATION HEADS <br /> PROPOSED PORTABLE P3 <br /> PROPOSED PORTABLE AND 12'BEYOND LOCATED BELOW GRAVEL PAD FOR PORTABLES. r o JAMEB LY/ETr <br /> 2T-8.5"X 32'-0.0' FACE OF RAMPS,TYP. PROPOSED PORTABLE <br /> 887 S.F. 27'-8.5"X 32'-0.0' 27'-8.5"X 32'-0.0" 13.CONTRACTORS TO PROTECT ALL EXISTING IRRIGATION VALVES,LATERALS AND S AT OF wash GTOH <br /> 887 S.F. FIRE EXTINGUISHER 887 S.F. MAIN LINES. <br /> ASPHALT MOUNTED ON INSIDE <br /> PAVING AS WALL NEXT TO <br /> C NECESSARY <br /> DOOR,TYP. PROJECT IDENTIFICATION: C <br /> FORACCESSIBLE 10'X 105'LANDING, <br /> ROUTE i:, <br /> STAIRS,AND 8'X/; 30' OPWITH� Jackson ES <br /> LMAX SLOPE 1:12I 1 Portables <br /> • RAMP DN. <br /> .,.... _ r _.,...,�,......,,-,..-....-..... _....,. , E lc <br /> ?---- --- - ---.__L..., Schools <br /> Everett u <br /> AT <br /> 3700 Federal Ave <br /> PROPOSED PORTABLE P5 - Everett WA 98201 <br /> 2T-8.5"X 32'-0.0" PROPOSED PORTABLE <br /> 887 S.F. 27,8.5"X 32,0.0" P6 <br /> /------- (RELOCATED PORTABLE 3) 887 S.F. PROPOSED PORTABLE PROPOSED PORTABLE PERMIT SET <br /> (RELOCATED PORTABLE 4) 2T-B.5"X 32'-0.0" <br /> 2T-8.5"X 32-0.0'1, ALIGN EDGE OF 887 S.F. 02/13/2024 <br /> 867 S.F. <br /> (RELOCATED PORTABLE B) (RELOCATED PORTABLE C) <br /> PORTABLE WITH <br /> I EDGE OF PAVEMENT This is: <br /> I <br /> 1.Copyright ynght2024 Dyhemn,Inc. <br /> 2.The Architects Instrument of Professional Service. <br /> B 1 3.For use on this project only.Obtain Architects B <br /> written permission for any other use or reproduction. <br /> PROJECT NUMBER: <br /> -- - -- J /. v..,,,,..... / 2023-056 <br /> ___-- - - - L J REVISIONS: <br /> i' <br /> i / / \\ WETLAND , MARK DATE DESCRIPTION <br /> ' <br /> -----� i SETBACK. N. <br /> 7N. <br /> / N. <br /> -- i' 80,0" \ N.N N.\ EXISTING <br /> ----� WBUF ER / \\\ \\ GRASS <br /> N. N <br /> N. \ <br /> N \ <br /> N \ <br /> N \ <br /> N\ \ PROJECT TEAM: <br /> \ <br /> \ \\ PRINCIPAL IN CHARGE)KGS <br /> \ \ PROJECT MANAGER: 12AH <br /> \\ \ PROJECTANCHITECT:I <br /> \ JOB CAPT DDF <br /> \ DRAWING TITLE: <br /> A \ \ A <br /> ` <br /> \\ - PARTIAL SITE PLAN - <br /> ----____ PORTABLES <br /> ----- D 4' 6' 16' DRAWING NUMBER: <br /> Scale:1/8"=1'-0" I" <br /> 0PARTIAL SITE PLAN- PORTABLES NORTH AS 1 . 1 <br /> , ) 2 I 3 I 4 I 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.