GENERAL STRUCTURAL NOTES: <br />CRITERIA: <br />1.1 All Materials, workmanship, design, and construction shall conform to the drawings, specifications, and the International Building Code (IBC), 2018 Edition. <br />1.2 <br />Design Loading Criteria <br />The Design Loading of the Structure is as follows: <br />Live Loads (in accordance with IBC Table 1607.1) <br />Occupancy or Use <br />Uniform Live <br />Load <br />Concentrated <br />Live Load <br />Notes <br />Floor, Residential <br />40-psf <br />- <br />Balconies & Decks <br />60-psf <br />- <br />1.5 x Occupancy Load <br />Uninhabitable attic, with storage <br />20-psf <br />- <br />Concurrent with Snow Loads <br />Unihabitable attic, without storage <br />10-psf <br />- <br />Non -concurrent with Snow Loads <br />Handrails and Guards <br />200-lbs <br />Any point, any direction (ASCE 7-16, Section 4.5.1) <br />Wind Design Data <br />ASCE 7-16, Chapter 28: Simplified Envelope Procedure <br />Basic Design Wind Speed (3-sec gust), V 100 mph <br />Risk Catagory II <br />Wind Exposure C <br />Internal Pressure Coefficient N/A <br />Exterior Components and Cladding 25-psf <br />Topographical Factor, Kzt 1.00 <br />Snow Loads <br />(ASCE 7-16, Chapter 7) <br />Ground Snow Load, Pg <br />25-psf <br />Flat Roof Snow Load, Pf = 0.7 Ce Ct Is Pg <br />25-psf <br />. Snow Exposure Factor, Ce <br />1.0 <br />. Snow Load Importance Factor, Is <br />1.0 <br />. Thermal Factor, Ct <br />1.2 <br />Do not adjust for slope or drift unless noted on the Drawings. <br />See Drawings for Additional Loading Criteria. <br />Seismic Design Data <br />ASCE 7-16, Section 12.8: Equivalent Lateral Force Procedure <br />Risk Catagory <br />II <br />Seismic Importance Factor, le <br />1.0 <br />Mapped Spect. Accel., Short Period, Ss <br />Mapped Spect. Accel., 1-Sec, S1 <br />1.383 <br />0.491 <br />Site Class <br />D <br />Spectral Response Coeff., Short Period, SIDS <br />Spectral Response Coeff., 1-Sec, SD1 <br />0.922 <br />0.592 <br />Seismic Design Catagory <br />D <br />Basic Seismic -Force -Resistance System <br />Ply. Shear Walls <br />Response Modification Factor, R <br />6.5 <br />Seismic Response Coefficient, Cs <br />0.15 <br />Design Base Shear, V <br />0.15 x Weight <br />Structural Drawings shall be used in conjunction with all other project documents for bidding and construction. Contractor shall verify dimensions and <br />conditions for compatibility and shall notify architect of all discrepancies prior to construction. <br />Contractor shall provide Temporary Bracing for the structure and structural components until all final connections have been completed in accordance with <br />the drawings. <br />Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. <br />Contractor -initiated changes shall be submitted in writing to the Architect and Structural Engineer for approval prior to fabrication or construction. Changes <br />shown on shop drawings only will not satisfy this requirement. <br />Drawings indicate general and typical details of construction. Where conditions are not specifically indicated but are of similar character to details shown, <br />similar details of construction shall be used, subject to review and approval by the Architect and the Structural Engineer. <br />All structural systems composed of components to be field erected shall be supervised by the Supplier during manufacturing, delivery, handling, storage and <br />erection in accordance with instructions prepared by the Supplier. <br />GEOTECHNICAL: <br />2.1 Allowable Soil Pressure, Lateral Earth Pressure, and Soil Profile Type are based on the provided Geotechnical Report. If soils are found to be other than <br />assumed, notify the Structural Engineer for possible foundation redesign. Footings shall bear on firm, undisturbed earth at least 18" below adjacent finished <br />grade. Unless otherwise noted, footings shall be centered below columns or walls above. Backfill behind all retaining walls with free draining, granular fill and <br />provide for subsurface drainage. <br />Geotechnical Properties <br />Soil Site Class D <br />Allowable Soil Bearing Pressure 2500-psf <br />Geotechnical Report Reference: Harbors Edge by Earth Solutions NW LLC, Project No: ES-7666, dated December 06, 2021. <br />CONCRETE: <br />3.1 Concrete shall be mixed, proportioned, conveyed and placed in accordance with IBC Chapter 19 and ACI 318-14. Mix shall be proportioned to produce a <br />slump of 5" or less. All concrete with surfaces exposed to standing water shall be air -entrained with an air -content conforming to ACI 318-14 Table 19.3.3.1 <br />Concrete Strength, based on IBC Section 1904.1, shall be as follows: <br />Type or Location of Concrete Construction <br />(Moderate Exposure) <br />Min. 28-Day Compressive Strength, fc <br />Interior Slabs -on -Grade <br />2500-psi <br />Footings, Basement Walls, Foundation/Stem Walls <br />3000-psis <br />Specified compressive strength (fc) specifications address serviceability requirements. Design <br />strength of concrete is 2500-psi, therefore, strength tests are not required. Provided concrete mix <br />tickets verifying strength specifications. <br />3.2 Reinforcing Steel shall conform to ASTM A615/A615M-18el and the following: <br />Bar Size <br />Steel Grade <br />#5 bar and larger <br />Grade 60, fy = 60,000-psi <br />#4 bar and smaller <br />Grade 40, fy = 40,000-psi <br />Welded Wire Fabric shall conform to ASTM Al064/A1064M-18a <br />3.3 Reinforcing Steel shall be detailed (including hooks and bends) in accordance with ACI 318-14. Lap all continuous reinforcement (#5 and smaller) 2'-0" <br />minimum. Laps of larger bars (#6 and #7) shall be 3-0", min. Provide corner bars at all wall and footing intersections and lap 2'-0" minimum. Lap adjacent <br />mats of welded wire fabric a minimum of 8" at sides and ends. <br />No bars partially embedded in hardened concrete shall be field bent unless otherwise noted on the drawings or approved by the structural engineer. <br />3.4 Concrete Protection (cover) for Reinforcing Steel shall be as follows: <br />Condition <br />Clear Cover <br />Footings and Unformed Surfaces cast against and permanently exposed to Earth <br />3" <br />Formed Surfaces exposed to Earth or Weather (#6 bars or larger) <br />2" <br />Formed Surfaces exposed to Earth or Weather (#5 bars or smaller) <br />1Y2" <br />Slabs and Walls, interior face (#11 bars and smaller) <br />3/4' <br />Column Ties or Spirals and Beam Stirrups <br />1Y2' <br />WOOD: <br />6.1 Framing Lumber shall be kiln dried or MC-19, and graded and marked in conformance with WCLB Standard Grading Rules for West Coast Lumber No. 17 <br />Unless otherwise noted, furnish to the following minimum standards: <br />Member Use <br />Size <br />Species <br />Grade <br />Studs <br />2x, 3x <br />Hem -Fir or SPF <br />STUD <br />Joists/Rafters <br />2x, 3x <br />Hem -Fir <br />No. 2 <br />Plates/Misc. <br />2x, 3x <br />Hem -Fir <br />No. 2 <br />Beams <br />4x <br />Douglas Fir -Larch <br />No. 2 <br />Posts <br />4x <br />Douglas Fir -Larch <br />No. 2 <br />Timber, Beams <br />6x & Larger <br />Douglas Fir -Larch <br />No. 2 <br />Timber, Posts <br />6x & Larger <br />Douglas Fir -Larch <br />No. 2 <br />6.2 Glued Laminated Members shall be fabricated in conformance with ASTM and AITC Standards. Each member shall bear an AITC Identification Mark and <br />shall be accompanied by an AITC certificate of conformance. Furnish to the following minimum standards: <br />Member Use <br />Combination <br />Species <br />Fbx+ <br />Fbx- <br />Fc1x <br />Fvx <br />Ex <br />Beams <br />24F-V4 <br />DF/DF <br />2400-psi <br />1850-psi <br />650-psi <br />265-psi <br />1800-ksi <br />Camber all glulam beams to 3,500' radius, unless otherwise noted. Glued laminated members exposed to <br />weather or moisture shall be treated with an approved preservative. <br />6.3 Engineered Wood shown on the drawings are based on product manufactured by Weyerhaeuser in accordance with ICC Report No. ES ESR-1387. <br />Alternate manufacturers may be used subject to review and approval by the Architect and Structural Engineer. All hangers and other hardware not shown <br />shall be designed and supplied by the Joist Manufacturer. Each piece shall bear a stamp or stamps noting the name and plant number of the manufacturer, <br />the grade, the ICC report number, and the quality control agency. Furnish to the following minimum standards: <br />6.4 <br />6.5 <br />Member Use <br />Product <br />Fb <br />Fcl <br />Fv <br />E <br />Beams <br />1.55E Laminated Strand Lumber (LSL) <br />2325-psi <br />800-psi <br />310-psi <br />1550-ksi <br />Beams <br />2.0E Laminated Veneer Lumber (LVL) <br />2600-psi <br />750-psi <br />285-psi <br />2000-ksi <br />Beams <br />2.0E Parallel Strand Lumber (PSL) <br />2900-psi <br />750-psi <br />290-psi <br />2000-ksi <br />Rim Boards <br />Laminated Strand Lumber (LSL) <br />1700-psi <br />680-psi <br />400-psi <br />1300-ksi <br />Engineered Wood I -Joists shown on the drawings are based on joists manufactured by Weyerhaeuser in accordance with ICC Report No. ES ESR-1153. <br />Alternate Engineered Wood I -Joists manufacturers may be used subject to review and approval by the Architect and Structural Engineer. <br />Prefabricated Connector Plate Wood Trusses shall be designed by the manufacturer in accordance with TPI 1-2014 for the spans and conditions shown on <br />the drawings. Wood trusses shall utilize approved connector plates (MITEK, ITW or other approved Truss Plate Manufacturer). <br />Unless otherwise noted, loading shall be as follows: <br />Roof Truss Design Loading <br />Member <br />Uniform Load <br />Top Chord Snow Load <br />25-psf <br />Top Chord Wind Load (Uplift) <br />15-psf <br />Top Chord Dead Load <br />7-psf <br />Bottom Chord Live Load <br />10-psf <br />Bottom Chord Dead Load <br />5-psf <br />Floor Truss Design Loading <br />Member <br />Uniform Load <br />Top Chord Live Load <br />40-psf <br />Top Chord Dead Load <br />10-psf <br />Bottom Chord Dead Load <br />5-psf <br />Submit shop drawings and design calculations prior to fabrication. Submitted documents shall bear the stamp and signature of a registered Professional <br />Engineer, State of Washington. Truss design drawings shall include, at a minimum, the following: <br />A. Slope or Depth, Span and Spacing <br />B. Location of all Joints and Support Locations <br />C. Number of Plies if greater than one <br />D. Required Bearing Widths <br />E. Design Loads and Locations: Include Top and Bottom Chord Live and Dead Loads, Girder Loads, and Environmental Loads (Seismic, Wind, Snow, etc.) <br />F. Other Lateral Loads, including Drag Strut Loads <br />G. Adjustments to Wood and Metal Connector Plate Design Value for Conditions of Use <br />H. Maximum Reaction Force and Direction (including Maximum Uplift) <br />I. Metal -Connector -Plate Type, Size, Thickness, and Location <br />J. Size Species and Grade for each Member <br />K. Truss -to -Truss Connections and Truss Field Assembly Requirements <br />L. Calculated Span -to -Deflection Ratio and maximum Vertical and Horizontal Deflection for Live and Total Loads <br />M. Maximum Axial Tension and Compression Forces in each Truss Member <br />N. Required Permanent Individual Truss Member Restraint Location and the Method and Details of Restraint Bracing to be used <br />O. Placement Layout including Bearing Points, Intersections, Hips, Valleys, etc. <br />P. Truss -to -Truss and Truss -to -Beam Connection Details and Hardware <br />6.6 Roof, Floor & Wall Sheathing shall be APA Rated, Exterior or Exposure 1 Plywood or OSB manufactured under the provisions of Voluntary Product <br />Standards DOC PS-1 or DOC PS-2, or APA PRP-108 Performance Standards and Policies for Structural Use Panels. See Drawings for thickness, span <br />rating, and nailing requirements. Unless otherwise noted, wall sheathing shall be'/" (nominal) with Span Rating of 24/0. Glue floor sheathing to all <br />supporting members with adhesive conforming to APA Specification AFG-01. <br />6.7 Wood members shall be protected against decay and termites in accordance with IBC Section 2304.12. Where required, members shall be natural) durable <br />P 9 Y q Y <br />species or shall be treated with waterborne preservatives wood in accordance with American Wood Protection Association specification AWPA U1. Members <br />shall be clearly labeled. Modifed treated members (ripped or end cut) shall be field treated in accordance with specification AWPA M4. <br />6.8 Timber Connectors and Proprietary Fasteners shall be "Strong -Tie" by Simpson Company, as specified in their current catalog. Provide number and size of <br />fasteners as specified by manufacturer. Connectors shall be installed in accordance with the manufacturer's instructions. Where connector straps connect <br />two members, center strap on joint and provide number and size of fasteners as specified by manufacturer, with equal number and size of fasteners in each <br />member. <br />Alternate hardware manufacturer substitutions, such as USP Connectors, shall be ICC approval for equal or greater load capacities. All joist hangers and <br />other hardware shall be compatible in size with specified framing members. See Hanger Conversion Table for pre -approved substitutions. <br />Timber Connectors and their fasteners shall be protected from corrosion in accordance with manufacturer's recommendations or ASTM A 653, Type G185. <br />6.9 Dowel -Type Fasteners (Bolts, Lag Screws, Wood Screws and Nails) shall conform to Sections 11 and 12 of the ANSI/AWC NDS-2018. <br />Dowel Type Fastener <br />Grade <br />Requirements at Exterior Use or <br />Installation <br />when in Contact w/ Treated Lumber <br />Bolts <br />ASTM A307 <br />ASTM B 695, Class 55 Galvanized <br />ANSI/AWC NDS-2018 Section 12.1.3 <br />or Stainless Steel <br />Hole = Bolt 0 + (1/32" to 1/16") <br />Washer @ Bolt Head and @ Nut <br />All-Thread/Threaded Rod <br />ASTM F1554 <br />ASTM B 695, Class 55 Galvanized <br />ANSI/AWC NDS-2018 Section 12.1.3 <br />or Stainless Steel <br />Hole = Rod 0 + (1/32" to 1/16") <br />Washer @ Each Nut <br />Lag Screws <br />ASTM A307 <br />ASTM A 153 Galvanized <br />ANSI/AWC NDS-2018 Section 12.1.4 <br />or Stainless Steel <br />Lead Hole = 0.5 x Shank 0, Shank Hole = Shank 0 <br />Washer @ Lag Head <br />Wood Screws <br />ASTM A 153 Galvanized <br />ANSI/AWC NDS-2018 Section 12.1.5 <br />or Stainless Steel <br />Pilot Hole = 0.75 x Root 0 (Unless Self -Boring) <br />Nails <br />ASTM F1667 <br />ASTM A 153 Galvanized <br />ANSI/AWC NDS-2018 Section 12.1.6 <br />or Stainless Steel <br />Avoid Overdriving or Underdriving, Avoid Wood Splitting <br />Toenails 300, 1/3 Nail Length from Joint <br />Nails specified on the drawings shall be as follows: <br />Nail Use <br />Penny <br />Weight <br />Grade <br />Framing Nails <br />12d Box <br />0.131 "0 x 3Y4' <br />Sheathing Nails <br />8d Common <br />0.131 "0 x 2Y2' <br />All Metal Fasteners exposed to weather or in contact with treated wood shall be protected from corrosion according to table above. Nuts and bolts exposed <br />to weather or in contact with treated wood shall be galvanized in accordance with ASTM Al53/A153M-16a or Stainless Steel. See above for Proprietary <br />Fastener requirements. Do not substitute standard Dowel -Type Fasteners for Proprietary Fasteners unless specifically allowed. <br />WOOD (Continued): <br />6.10 Wood Framing Notes: The following apply unless otherwise noted on the drawings: <br />A. All wood framing details shall be constructed to the minimum standards of the IBC. Nailing not specified on the drawings shall conform to IBC Table <br />2304.10.1 or ICC ES ESR-1539. Coordinate the size and location of all openings with Mechanical and Architectural Drawings. <br />B. Wall Framing: Stud wall size and spacing shall be in accordance with the plan notes. Two studs minimum shall be provided at the ends of all walls, at <br />each side of all openings, and at the ends of all beams and headers. All stud bearing walls on wood framing shall have their lower wood plates attached <br />to framing or concrete below per P1-6 of the shear wall schedule. <br />C. Individual members of Built -Up stud posts shall be nailed to each other with framing nails @ 12"oc, staggered. Individual members of Built -Up joist <br />beams shall be nailed to each other with framing nails @ 12"oc, staggered. <br />D. Solid blocking for wood columns shall be provided through floors to supports below. <br />E. Floor and Roof Framing: Provide solid blocking at all bearing points. Toenail joists to supports with two framing nails. Attach timber joists to flush <br />headers or beams with metal joist hangers in accordance with notes above. <br />F. Roof and floor sheathing shall be laid up with grain perpendicular to supports and nailed per plan notes. Allow 1/8" spacing at all panel edges and ends <br />of floor and roof sheathing. Provide approved panel edge clips centered between joists/trusses at unblocked roof sheathing edges. All floor sheathing <br />edges shall have approved tongue -and -groove joints. Toenail blocking to supports with framing nails @ 12"oc. At blocked floor and roof diaphragms, <br />provide flat 2x blocking at all unframed panel edges and nail with edge nailing specified. <br />QUALITY ASSURANCE: <br />7.1 See Special Inspection and Testing Requirements Table for inspection and testing requirements. Special Inspection shall be in accordance with IBC Section <br />1704.2. Standard inspections shall be in accordance with IBC Section 110. <br />7.2 Structural Observation in accordance with IBC Section 1704.6 is not required. <br />SPECIAL INSPECTION AND TESTING REQUIREMENTS <br />Verification and Inspection <br />Continuous <br />Periodic <br />Comments <br />Wood Shear Walls: Nailing (panel <br />edges and holdowns) <br />x <br />Not req'd for P1-6 <br />Soils <br />Refer to Geotechnical Report Requirements <br />1 <br />rVT,J <br />^ <br />y <br />� <br />V <br />W0 <br />0 <br />w <br />z <br />x <br />BTLI <br />ENGINEERING P.S. <br />1.,S_ No <br />T. <br />�OF AS9/� <br />0 <br />z <br />565666 <br />eelezlzezz <br />Revlslon schedT o <br /># <br />DESCRIPTION <br />DATE <br />PERMIT SET <br />09/02/2022 <br />1 <br />CITY COMMENTS <br />05/17/2023 <br />2 <br />REVISIONS <br />11/30/2023 <br />J <br />Q <br />D W <br />LLJ <br />Z 0 <br />Q <br />LLJ Z <br />VJ <br />X <br />Q) <br />LL <br />1 <br />.. <br />EC <br />O a, <br />C <br />i <br />U) <br />O <br />Z <br />cC <br />Cl) <br />O <br />E <br />O <br />> <br />O <br />W <br />cc <br />W <br />W <br />U) <br />i <br />O <br />CZ <br />2 <br />SAGI HOME-5 <br />S <br />T <br />u o a IT w e s r <br />Sage Homes Northwest <br />9505 19th Ave SE <br />Suite 118 <br />Everett, WA 98208 <br />www.sagehomesnw.com <br />JOB NO.: <br />22-447-02 <br />PLOT DATE <br />09/02/2022 <br />DATE: 09/02/2022 <br />SCALE: Ya" = 1'-0.. <br />DRAWN: BIDS <br />CHCKD: RMH <br />SHEET NO.: <br />S01 <br />