Laserfiche WebLink
Viking Plastics BlazeMastere CPVC Pipe <br />MA& <br />CPVC Pipe Product Specifications <br />Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- <br />lation instructions, is UL and aUL Listed by Underwriters Laboratories for use in the following: <br />• Meets NFPA 1 ME and 1 So standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. <br />• Residential occupancies up is and including four stories in height as defined by N EPA 13P <br />• Residential occupancies as defined n the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 1 So. <br />• Installation of private fire service mains and their appurtenances, N EPA 24. <br />CPVCfire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. <br />CPVC pipe must never be used in a system using compressed air or other gases <br />CPVC pipe from Viking Plastics also carries the follow- <br />ing enhanced listings and approvals: <br />According to U LLsting <br />• Can be flush at return air plenums <br />• Exposed system risers NFPA 15o,13P <br />• Exposed basement NFPA 13D (solid woodJoist) <br />• Extended coverage (exposed) <br />• 20'spacing on pendent in lieu of 15' <br />• 15'spacing on sldewall In lieu of 14' <br />• Use with combustible concealed spnnklers <br />• red amc sprinkler head (to pm@cttifenmr below) <br />• red amc sprinkler head with wet system piping <br />(feed main and ridge Installation) <br />New and enhanced listings and approvals are being pursued Always <br />check with the appropriate Listing andAppmval agency for details on <br />current lining parameters <br />CPVC pipe meets all applicable standards for pressure rated applies <br />for as required In ANSI CST Standard 14 and complies with ANSI CST <br />Standard 61 for health effects and are marked with the CST do anti use <br />marking <br />At CHAD fire sprinkler pipe shall be Listed by Underwriters Laboratories <br />forwet pipe systems, and shall carry rated working pressure of 175 pa <br />@ 150°F (12 bar@ 655°C).'The FMAppmval Is limited to use In wet <br />pipe fire protection sprinkler systems for light hazard occupancies In both <br />concealed and exposed applications with curtain restrictions. <br />Piping must always be Installed In arid accordance to the manufacturer's <br />DESIGN AND INSTALLATION GUIDE Including product storage and <br />handling, joining methods, suppohlug and bracing, expansion and coo- <br />tradier allowance and resume, ern National Fire Protection Association <br />(NFPA1 Standards 13,13D, and 13P must be referenced for design and <br />installation requirements in conjunction with the installation instructions <br />Exposed sldewall sprinkler listing for exposed pipe & fittings <br />• 24extended coverage sldewall sprinkler, 12" dmp, 155°F <br />sprinkler head <br />• 15' extended coverage sldewall sprinkler, 12" dmp, 165°F <br />sprinkler head <br />• 16' extended coverage sldewall sprinkler 12" dmp, 175°F <br />sprinkler head <br />• 14'standard coverage sidewall sprinkler, 12' drop , Zoo°F <br />sprinkler head <br />Factory Mutual Appmved' <br />• Factory Mutual Approval exposed <br />• Factory Mutual Approval above tlmp in ceilings <br />• Factory Mutual Approval exposed w/SoflFSteel soflltlng <br />covering system <br />All CPVC fire sprinkler pipe from Viking Chancels manufactured In the <br />USA At CPVC pipe shall be packaged immediately after its manufacture <br />to prevent damage and shall be stored indoors after production, at the <br />manufacturing site until shipped from the factory. The pipe shall bear the <br />logo of the lining agendas, and shall curry the National Sanitation Fourr <br />nation (NSF) seal of approval for potable water applications <br />CPVC products are intended for use In areas where the maximum ambi <br />ant temperature does not exceed 150°F @55°C). If the ambient tempera <br />wra is expected to exceed this limitation, refer to the manufacturer's OF <br />SIGN AND INSTALLATION GUIDE for additional information on methods <br />to reduce the pipe exposure temperatures CPVC pipe is not intended to <br />be installed In outdoor applications. CPVC pipe Is intended to be used In <br />wet pipe systems only and have not been investigated for use In dry pipe <br />systems. Special Installation and design criteria relative to pipe hanger <br />spacings, piping and sprinkler restraint, sprinkler temperature rating, <br />piping locations, testing procedures and fiction lass characteristics are <br />specified in the manufacturer's installation Instructions provided with the <br />pipe. The manufacturer's Installation Instructions should be reviewed and <br />the Authority Having Jurisdiction consulted before installation. <br />Trusted above all" <br />NIKING° <br />