My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE PORTABLE 4 JACKSON ELEMENTARY 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE PORTABLE 4 JACKSON ELEMENTARY 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 1:54:26 PM
Creation date
6/17/2025 7:17:56 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Unit
PORTABLE 4
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application <br />Installation <br />The SIGA-CCiS mounts to a standard North American two -gang <br />electrical box, making it ideal for locations where only one module <br />is required. Separate 1/0 and data loop connections are made to <br />each module. <br />The SIGA-MCCiS is part of the UIO family of plug-in Signature <br />Series modules. It functions identically to the SIGA-CC1 S, but <br />takes advantage of the modular flexibility and easy installation that <br />characterize all UIO modules. Two- and six -module UIO mother- <br />boards are available. These can accommodate individual risers for <br />each on -board module, or risers that are shared by any combina- <br />tion of its UIO modules. All wiring connections are made to termi- <br />nal blocks on the motherboard. UIO assemblies may be mounted <br />in EDWARDS enclosures. <br />Personality Codes <br />The operation of the SIGA-CC1 S is determined by their sub -type <br />code or "Personality Code". The code is selected by the installer <br />depending upon the desired application and is downloaded from <br />the loop controller. <br />Personality Code 5: Signal Power or Audio Evacuation (sin- <br />gle riser). Configures the module for use as a Class B Audible/ <br />Visible Signal power (24 Vdc polarized) or Audio Evacuation (25 <br />or 70 VRMS) power selector. The ring -tone generator is disabled. <br />The output circuit is monitored for open or shorted wiring. If a <br />short exists, the control panel inhibits the activation of the audible/ <br />visible signal circuit to prevent connection to the power circuit. <br />Personality Code 6: Telephone with ring -tone (single riser). <br />Configures the module for use as a Telephone power selector. <br />When a telephone handset is plugged into its jack or lifted from its <br />hook, the module generates its own Ring -Tone signal. A separate <br />ring -tone circuit is not needed. The module sends this signal to <br />the control panel to indicate that an off -hook condition is present. <br />When the system operator responds to the call, the ring -tone <br />signal is disabled. <br />Personality Code 25: Visual Signal Synchronization. This <br />personality code configures the module to provide synchronization <br />of fire alarm signals across multiple zones. It functions as a signal <br />power (24 Vdc) riser selector. The output wiring is monitored for <br />open circuits and short circuits. A short circuit will cause the fire <br />alarm control panel to inhibit the activation of the audible/visual <br />signal circuit so the riser is not connected to the wiring fault. <br />Warnings & Cautions <br />This module will not operate without electrical power. As fires fre- <br />quently cause power interruption, we suggest you discuss further <br />safeguards with your fire protection specialist. <br />EDWARDS recommends that these modules be installed accord- <br />ing to latest recognized edition of national and local fire alarm <br />codes. <br />Compatibility <br />These modules are part of EDWARDS's Signature Series intelligent <br />processing and control platform. They are compatible with EST3, <br />EST3X and iO Series control panels. <br />The SIGA-CCiS: mounts to North American 2-1/2 inch (64 mm) <br />deep 2-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square <br />boxes with 2-gang covers and SIGA-MP mounting plates. The <br />terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) <br />wire size. <br />SIGA-MCCiS: mount the UIOxR motherboard inside a suitable <br />EDWARDS enclosure with screws and washers provided. Plug the <br />module into any available position on the motherboard and secure <br />the module to the motherboard with the captive screws. Wiring <br />connections are made to the terminals on the motherboard (see <br />wiring diagram). UIOxR motherboard terminals are suited for #12 <br />to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. <br />U10 Motherboard <br />Plug-in (00) <br />Module <br />�Cebinet or electncel enclosure <br />Electronic Addressing <br />The loop controller electronically addresses each module saving <br />valuable time during system commissioning. Setting complicated <br />switches or dials is not required. Each module has its own unique <br />serial number stored in its "on -board memory". The loop control- <br />ler identifies each device on the loop and assigns a "soft" address <br />to each serial number. If desired, the modules can be addressed <br />using the SIGA-PRO Signature Program/Service Tool. <br />Testing & Maintenance <br />The module's automatic self -diagnosis identifies when it is defec- <br />tive and causes a trouble message. The user-friendly maintenance <br />program shows the current state of each module and other perti- <br />nent messages. Single modules may be turned off (de -activated) <br />temporarily, from the control panel. <br />Scheduled maintenance (Regular or Selected) for proper system <br />operation should be planned to meet the requirements of the <br />Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and <br />ULC CAN/ULC 536 standards. <br />Page 2 of 4 <br />DATA SHEET E85001-0543 <br />Not to be used for installation purposes. Issue 1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.