1 2
<br />3
<br />4
<br />5
<br />6
<br />7
<br />8
<br />9
<br />10
<br />DESIGN ARCHITECT
<br />F
<br />E
<br />D
<br />C
<br />B
<br />A
<br />ABBREVIATIONS
<br />AC
<br />ASPHALTIC CONCRETE
<br />H
<br />HIGH
<br />ACC
<br />ACCESSIBLE
<br />HB
<br />HOSE BIBB
<br />ACP
<br />ACOUSTICAL CEILING PANEL
<br />HC
<br />HOLLOW CORE
<br />ACST
<br />ACOUSTICAL
<br />HD
<br />HAND DRYER
<br />AD
<br />AREA DRAIN
<br />HDBD
<br />HARDBOARD
<br />ADDM
<br />ADDENDUM
<br />HDW
<br />HARDWARE
<br />ADJ
<br />ADJUSTABLE
<br />HDWD
<br />HARDWOOD
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />HM
<br />HOLLOW METAL
<br />AHU
<br />AIR HANDLING UNIT
<br />HO
<br />HOLD OPEN
<br />ALT
<br />ALTERNATE
<br />HORIZ
<br />HORIZONTAL
<br />ALUM
<br />ALUMINUM
<br />HR
<br />HOUR
<br />ANOD
<br />ANODIZED
<br />HT
<br />HEIGHT
<br />APPROX
<br />APPROXIMATE
<br />HVAC
<br />HEATING, VENTILATING
<br />APT
<br />APARTMENT
<br />ANDAIR-CONDITIONING
<br />ARCH
<br />ARCHITECT, ARCHITECTURAL
<br />AUTO
<br />AUTOMATIC
<br />ID
<br />INSIDE DIAMETER
<br />AV
<br />AUDIO VISUAL
<br />INCL
<br />INCLUDE, INCLUDING
<br />AWP
<br />ACOUSTICAL WALL PANEL(S)
<br />INFO
<br />INFORMATION
<br />INSUL
<br />INSULATE, INSULATION
<br />BB
<br />BULLETIN BOARD
<br />INT
<br />INTERIOR
<br />BD
<br />BOARD
<br />IWD
<br />INDIRECT WASTE DRAIN
<br />BLDG
<br />BUILDING
<br />BLKG
<br />BLOCKING
<br />JAN
<br />JANITOR
<br />BO
<br />BOTTOM OF
<br />JT
<br />JOINT
<br />BOT
<br />BOTTOM
<br />BRIG
<br />BEARING
<br />KIT
<br />KITCHEN
<br />BRZ
<br />BRONZE
<br />BSMT
<br />BASEMENT
<br />L
<br />LONG
<br />BUR
<br />BUILT UP ROOFING
<br />LAM
<br />LAMINATE, LAMINATED
<br />LAU
<br />LAUNDRY
<br />CAB
<br />CABINET
<br />LAV
<br />LAVATORY
<br />CB
<br />CATCH BASIN
<br />LT
<br />LIGHT
<br />GEM
<br />CEMENT, CEMENTITIOUS
<br />LTG
<br />LIGHTING
<br />CER
<br />CERAMIC
<br />CG
<br />CORNER GUARD
<br />MAS
<br />MASONRY
<br />CH
<br />COAT HOOK
<br />MAIL
<br />MATERIAL
<br />Cl
<br />CAST IRON
<br />MAX
<br />MAXIMUM
<br />CJ
<br />CONTROL JOINT
<br />MECH
<br />MECHANICAL
<br />CIP
<br />CAST -IN -PLACE
<br />MED
<br />MEDIUM
<br />CL
<br />CENTERLINE
<br />MEMB
<br />MEMBRANE
<br />CLG
<br />CEILING
<br />MEZZ
<br />MEZZANINE
<br />CLO
<br />CLOSET
<br />MGT
<br />MANAGEMENT
<br />CLR
<br />CLEAR
<br />MFR
<br />MANUFACTURER
<br />CMU
<br />CONCRETE MASONRY UNIT
<br />MH
<br />MANHOLE
<br />CO
<br />CLEAN OUT, CASED OPENING
<br />MIN
<br />MINIMUM, MINUTE
<br />COL
<br />COLUMN
<br />MISC
<br />MISCELLANEOUS
<br />COMM
<br />COMMUNICATION
<br />MO
<br />MASONRY OPENING
<br />CONC
<br />CONCRETE
<br />MS
<br />MOP SINK
<br />CONN
<br />CONNECTION, CONNECT
<br />MTD
<br />MOUNTED
<br />CONSTR
<br />CONSTRUCTION
<br />MTL
<br />METAL
<br />CONT
<br />CONTINUOUS, CONTINUE
<br />MVBL
<br />MOVABLE
<br />CORR
<br />CORRIDOR
<br />CPT
<br />CARPET
<br />N
<br />NORTH
<br />CSWK
<br />CASEWORK
<br />NIC
<br />NOT IN CONTACT
<br />CTR
<br />CENTER
<br />NO
<br />NUMBER
<br />CU
<br />CUBIC
<br />NOM
<br />NOMINAL
<br />NTS
<br />NOT TO SCALE
<br />D
<br />DEEP, DEPTH
<br />DBL
<br />DOUBLE
<br />OC
<br />ON CENTER
<br />DEMO
<br />DEMOLISH, DEMOLITION
<br />OH
<br />OVERHEAD
<br />DET
<br />DETAIL
<br />OD
<br />OUTSIDE DIAMETER
<br />DF
<br />DRINKING FOUNTAIN
<br />OPNG
<br />OPENING
<br />DIA
<br />DIAMETER
<br />OPP
<br />OPPOSITE
<br />DIAG
<br />DIAGONAL, DIAGRAM
<br />ORD
<br />OVERFLOW ROOF DRAIN
<br />DIM
<br />DIMENSION
<br />OTS
<br />OPEN TO STRUCTURE
<br />DIV
<br />DIVIDE, DIVISION
<br />ABOVE
<br />DMPF
<br />DAMPPROOF,DAMPPROOFING
<br />DN
<br />DOWN
<br />PBD
<br />PARTICLEBOARD
<br />DR
<br />DOOR, DRESSING ROOM
<br />PRCST
<br />PRECAST
<br />DS
<br />DOWNSPOUT
<br />PD
<br />PLANTER DRAIN
<br />DW
<br />DISHWASHER
<br />PERP
<br />PERPENDICULAR
<br />DWG
<br />DRAWING
<br />PLAM
<br />PLASTIC LAMINATE
<br />DWR
<br />DRAWER
<br />PLAS
<br />PLASTER
<br />PLYWD
<br />PLYWOOD
<br />E
<br />EAST
<br />PNL
<br />PANEL
<br />EIFS
<br />EXTERIOR INSULATION AND
<br />PL
<br />PROPERTY LINE
<br />FINISH2SYSTEM
<br />PR
<br />PAIR
<br />EJ
<br />EXPANSION JOINT
<br />PRKG
<br />PARKING
<br />EL
<br />ELEVATION
<br />PROP
<br />PROPERTY
<br />ELEC
<br />ELECTRIC, ELECTRICAL
<br />PT
<br />PAINT, POINT
<br />ELEV
<br />ELEVATOR
<br />PTN
<br />PARTITION
<br />ENCL
<br />ENCLOSE, ENCLOSURE
<br />EP
<br />ELECTRIC PANEL
<br />R
<br />RADIUS, RISER
<br />EQ
<br />EQUAL
<br />RCP
<br />REFLECTED CEILING PLAN
<br />EQUIP
<br />EQUIPMENT
<br />RD
<br />ROOF DRAIN, ROAD
<br />ESCAL
<br />ESCALATOR
<br />REF
<br />REFER TO, REFERENCE
<br />EXH
<br />EXHAUST
<br />REF
<br />REFRIGERATOR
<br />EXP
<br />EXPANSION, EXPOSED
<br />REINF
<br />REINFORCED, REINFORCING
<br />EXIST
<br />EXISTING
<br />REQD
<br />REQUIRED
<br />REV
<br />REVISED, REVISION
<br />RFG
<br />ROOFING
<br />FA
<br />FIRE ALARM
<br />RM
<br />ROOM
<br />FCIC
<br />FURNISHED BY CONTRACTOR/
<br />RO
<br />ROUGH OPENING
<br />INSTALLED BY CONTRACTOR
<br />RT
<br />RIGHT
<br />FCIO
<br />FURNISHED BY CONTRACTOR/
<br />INSTALLED BY OWNER
<br />S
<br />SOUTH
<br />FD
<br />FLOOR DRAIN
<br />SAM
<br />SELF ADHERING MEMBRANE
<br />FDC
<br />FIRE DEPARTMENT
<br />SC
<br />SOLID CORE
<br />CONNECTION
<br />SCHED
<br />SCHEDULE
<br />FDTN
<br />FOUNDATION
<br />SD
<br />STORM DRAIN
<br />FE
<br />FIRE EXTINGUISHER
<br />T
<br />SECT
<br />SECTION
<br />FEC
<br />FIRE EXTINGUISHER
<br />SINGLE
<br />CABINET
<br />SHT
<br />SHEET
<br />FH
<br />FIRE HYDRANT
<br />SHTHG
<br />SHEATHING
<br />FHC
<br />FIRE HOSE CABINET
<br />SIM
<br />SIMILAR
<br />FIG
<br />FIGURE
<br />SPEC
<br />SPECIFICATION
<br />FIN
<br />FINISH, FINISHED
<br />SPKLR
<br />SPRINKLER
<br />FLEX
<br />FLEXIBLE
<br />FUR
<br />FLOOR, FLOORING
<br />SPKR
<br />SPEAKER
<br />FLUOR
<br />FLUORESCENT
<br />SQ
<br />SQUARE
<br />FO
<br />FACE OF, FINISHED OPENING
<br />SS
<br />SERVICE SINK
<br />FOIC
<br />FURNISHED BY OWNER/
<br />SST
<br />STAINLESS STEEL
<br />INSTALLED BY CONTRACTOR
<br />STC
<br />SOUND TRANSMISSION CLASS
<br />FOIO
<br />FURNISHED BY OWNER/
<br />STD
<br />STANDARD
<br />INSTALLED BY OWNER
<br />STSTD
<br />STEEL
<br />FP
<br />FIRE PROTECTION, FIREPROOF
<br />OR
<br />STORAGE
<br />FR
<br />FRAME, FIRE RATED
<br />STRUCT
<br />STRUCTURAL
<br />FRMG
<br />FRAMING
<br />SUSP
<br />SUSPENDED
<br />FRPF
<br />FIREPROOF, FIREPROOFING
<br />FRT
<br />FIRE RETARDANT TREATED
<br />T
<br />TREAD
<br />FS
<br />FLOOR SINK
<br />T&G
<br />TONGUE AND GROOVE
<br />FT
<br />FOOT, FEET
<br />TEL
<br />TELEPHONE
<br />FTG
<br />FOOTING
<br />TEMP
<br />TEMPERATURE, TEMPORARY
<br />FUT
<br />FUTURE
<br />TER
<br />TERRAllO
<br />FVC
<br />FIRE HOSE VALVE CABINET
<br />THK
<br />THICK, THICKNESS
<br />FWC
<br />FABRIC WALL COVERING
<br />TMPD
<br />TEMPERED
<br />FWP
<br />FABRIC WRAPPED PANEL(S)
<br />TO
<br />TOP OF
<br />TSTAT
<br />THERMOSTAT
<br />GA
<br />GAGE
<br />TV
<br />TELEVISION
<br />GALV
<br />GALVANIZED
<br />TYP
<br />TYPICAL
<br />GEN
<br />GENERAL, GENERATOR
<br />GFRC
<br />GLASS -FIBER
<br />UGND
<br />UNDERGROUND
<br />REINFORCED CONCRETE
<br />UNFIN
<br />UNFINISHED
<br />GFRG
<br />GLASS -FIBER
<br />LION
<br />UNLESS OTHERWISE NOTED
<br />REINFORCED GYPSUM
<br />GFRP
<br />GLASS -FIBER
<br />VERT
<br />VERTICAL
<br />REINFORCED PLASTIC
<br />VEST
<br />VESTIBULE
<br />GL
<br />GLASS
<br />VIF
<br />VERIFY IN FIELD
<br />GYP
<br />GYPSUM
<br />VNR
<br />VENEER
<br />GYP BD
<br />GYPSUM BOARD
<br />VR
<br />VAPOR RETARDER
<br />VWC
<br />VINYL WALLCOVERING
<br />W
<br />WEST, WIDE
<br />WI
<br />WITH
<br />W/o
<br />WITHOUT
<br />WC
<br />WATER CLOSET, WALLCOVERING
<br />WD
<br />WOOD
<br />WH
<br />WALL HYDRANT
<br />WP
<br />WEATHERPROOF,WATERPROOF,
<br />WATERPROOFING, WORK POINT
<br />WR
<br />WATER RESISTANT
<br />WT
<br />WEIGHT 4
<br />WWF
<br />WELDED WIRE FABRIC
<br />XFMR TRANSFORMER
<br />REFERENCE SYMBOLS
<br />SECTION
<br />XX
<br />A-XXX A-XXX
<br />SHEET NUMBER
<br />BUILDING SECTION INDICATOR
<br />SECTION
<br />A-XXX
<br />SHEET NUMBER
<br />WALL SECTION INDICATOR
<br />DETAIL
<br />XX
<br />A-XXX
<br />SHEET NUMBER
<br />SECTION DETAIL INDICATOR
<br />DETAIL
<br />A -
<br />SHEET NUMBER
<br />DETAIL INDICATOR
<br />ELEVATION
<br />XX
<br />I :
<br />A-XXX
<br />SHEET NUMBER
<br />EXTERIOR ELEVATION INDICATOR
<br />ELEVATION
<br />SHEET NUMBER
<br />X-XXX
<br />INTERIOR ELEVATION INDICATOR
<br />MATCH LINE
<br />SEE XX/A-M
<br />MATCHLINE INDICATOR
<br />x.x x.x
<br />NEW COLUMN GRID
<br />INDICATED AND GRID LINES
<br />X.X X.X
<br />NEW GRID INDICATOR AND GRID
<br />LINES AT FACE OF FOUNDATION
<br />EL 100.00'
<br />SPOT ELEVATION INDICATOR
<br />DATUM INDICATOR
<br />ROOM NAME
<br />2022
<br />ROOM NAME AND NUMBER
<br />SOUTHPOINT PLAZA - FIRE DAMAGE REPAIR
<br />EVERETT, WASHINGTON
<br />BUILDING CODE INFORMATION
<br />SITE ADDRESS: 10121 EVERGREEN WAY #1, EVERETT, WA
<br />LEASE AREA: 2,318 SF SINGLE LEVEL (EXISTING)
<br />APPLICABLE CODES:
<br />BUILDING CODE:
<br />2018 INTERNATIONAL EXISTING BUILDING CODE (IBC)
<br />MECHANICAL CODE:
<br />2018 INTERNATIONAL MECHANICAL CODE (IMC)
<br />FIRE CODE:
<br />2018 INTERNATIONAL FIRE CODE (IFC)
<br />ENERGY CODE:
<br />2018 WASHINGTON STATE ENERGY CODE (WSEC)
<br />PLUMBING CODE:
<br />2018 UNIFORM PLUMBING CODE (UPC
<br />ELECTRICAL CODE:
<br />2020 NATIONAL ELECTRIC CODE (NFPA 70)
<br />OCCUPANCY GROUP: M
<br />CONSTRUCTION TYPE: V-B
<br />SPRINKLERED: NO (NONE EXISTING)
<br />FIRE ALARM SYSTEM: NO (NONE EXISTING)
<br />SITE PLAN
<br />I:IIIIIIIIIIIIIIIIIIIIIIIIIII MINE
<br />Y
<br />4,200 sf
<br />a
<br />oursaeK
<br />a
<br />Mattress
<br />a
<br />Center
<br />SW EVERETT MALL WAY
<br />PROJECT SITE
<br />DRAWING INDEX
<br />ARCHITECTURAL
<br />ARCHITECTURAL
<br />GENERAL INFORMATION
<br />A-001
<br />EGRESS PLAN
<br />A-101
<br />DEMO FLOOR PLAN
<br />A-103
<br />FLOOR PLAN
<br />A-104
<br />CEILING PLAN
<br />A-105
<br />ROOF PLAN
<br />A-201
<br />EXTERIOR ELEVATIONS
<br />A-401
<br />ENLARGED PLANS - RESTROOM
<br />A-501
<br />EXTERIOR DETAILS
<br />A-601
<br />DOOR SCHEDULES
<br />A-801
<br />DETAILS
<br />STRUCTURAL
<br />n 7
<br />GENERAL NOTES
<br />S-002
<br />GENERAL NOTES
<br />S-003
<br />GENERAL NOTES
<br />S-101
<br />FOUNDATION PLANTLOOR PLAN
<br />S-102
<br />ROOF FRAMING PLAN
<br />S-501
<br />DETAILS
<br />S-502
<br />DETAILS
<br />MECHANICAL
<br />I01U.T-- HVAC LEGEND, SCHEDULES
<br />MD1.1 DEMOLITION ROOF PLAN
<br />M1.1 HVAC ROOF PLAN
<br />PLUMBING
<br />PIf1 PLUMBING LEGEND, SCHEDULES, DETAILS
<br />P0.2 PLUMBING SCHEDULES
<br />P1.1 PLUMBING PLANS
<br />P2.1 PLUMBING RISER DIAGRAMS
<br />ELECTRICAL
<br />EU.T— ELECTRICAL SYMBOLS AND ABBREVIATIONS
<br />E0.2 ELECTRICAL SPECIFICATIONS
<br />E0.3 ELECTRICAL SCHEDULES
<br />E3.1 ELECTRICAL FLOOR PLAN
<br />E8.1 ELECTRICAL ONE LINE DIAGRAM
<br />PROJECT DIRECTORY
<br />OWNER:
<br />ROIC
<br />11250 EL CAMINO REAL, SUITE 200
<br />SAN DIEGO, CA 92130
<br />PHONE: (858) 255-4920
<br />CONTACT: ROBERT DORAN
<br />EMAIL: RDORAN@ROIREIT.NET
<br />GENERAL CONTRACTOR:
<br />SELECT CONTRACTING
<br />PHONE: 206-419-8871
<br />CONTACTNIKEJOHNSON
<br />EMAIL: selectcontracting@comcast.net
<br />ARCHITECT:
<br />SDH ARCHITECT, LLC
<br />2242 NW RESERVE CAMP CT
<br />BEND, OR 97703
<br />PHONE: 206-369-8881
<br />CONTACT: SCOTT HARRIS
<br />EMAIL:SCOTT.HARRIS@SDHARCHITECT.COM
<br />STRUCTURAL:
<br />AUE
<br />PHONE: 425-614-5078
<br />CONTACT: ALEX HABLISTON
<br />EMAIL:ALEXH AU-ENG.COM
<br />MECHANICAUPLUMBINGIELECTRICAL ENGINEER:
<br />METRIX ENGINEERS
<br />PHONE: 206-920-9240
<br />CONTACT: SCOTT MILLER
<br />EMAIL:SCOTTM@METRIXENG.COM
<br />GENERAL NOTES
<br />1. DO NOT SCALE THE DRAWINGS.
<br />2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE
<br />WORK.
<br />3. THE CONTRACT DOCUMENT ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE
<br />SHALL BE BINDING IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL
<br />PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE
<br />ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
<br />4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS
<br />OTHERWISE INDICATED.
<br />5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE
<br />LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE
<br />OF THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER DOORS AND
<br />CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTIONS.
<br />6. ALL ANGLED WALLS ARE 45°, 90° OR 135° UON.
<br />7. ALL WOOD BACKERS AND NAILERS SHALL BE FIRE RETARDANT.
<br />SCOPE OF WORK
<br />STRUCTURAL REPAIR OF AN EXISTING COMMERCIAL BUILDING
<br />DAMAGED BY FIRE. REPLACEMENT OF DAMAGED PORTION OF
<br />STRUCTURE FROM FIRE, WITH NEW STRUCTURAL, LIKE FOR LIKE.
<br />NEW HVAC UNITS TO REPLACE DAMAGED UNITS, LIKE FOR LIKE.
<br />REPLACEMENT OF STOREFRONT, LIKE FOR LIKE. NO CHANGE IN USE
<br />OR OCCUPANCY.
<br />TENANT BUILD OUT AND OCCUPANCY BY OTHERS UNDER SEPARATE
<br />PERMIT.
<br />SDH Architect
<br />2242 NW RESERVE CAMP CT
<br />BEND, OR 97703
<br />206.369.8881
<br />OWNER
<br />ROIC of WASHINGTON
<br />8905 Towne Center Drive, Suite 108
<br />San Diego, CA 92122
<br />CONSULTANT
<br />SEAL
<br />V197219
<br />RLGISTERED
<br />ARCHITECT
<br />SCOTT DAVID HARRIS
<br />STATE OF WASHINGTON
<br />SOUTHPOINT PLAZA
<br />SUITE 1 - REPAIR
<br />10121 EVERGREEN WAY #1
<br />EVERETT, WA
<br />ISSUED / REVISED DATE
<br />PERMIT SET 06.26.23
<br />PR 01-SOCCER POST 01.26.24
<br />PR 02 06.24.24
<br />PR-01 SOCCER POST 01.26.24
<br />GENERAL
<br />INFORMATION
<br />A-000
<br />
|