Laserfiche WebLink
1 2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />DESIGN ARCHITECT <br />F <br />E <br />D <br />C <br />B <br />A <br />ABBREVIATIONS <br />AC <br />ASPHALTIC CONCRETE <br />H <br />HIGH <br />ACC <br />ACCESSIBLE <br />HB <br />HOSE BIBB <br />ACP <br />ACOUSTICAL CEILING PANEL <br />HC <br />HOLLOW CORE <br />ACST <br />ACOUSTICAL <br />HD <br />HAND DRYER <br />AD <br />AREA DRAIN <br />HDBD <br />HARDBOARD <br />ADDM <br />ADDENDUM <br />HDW <br />HARDWARE <br />ADJ <br />ADJUSTABLE <br />HDWD <br />HARDWOOD <br />AFF <br />ABOVE FINISHED FLOOR <br />HM <br />HOLLOW METAL <br />AHU <br />AIR HANDLING UNIT <br />HO <br />HOLD OPEN <br />ALT <br />ALTERNATE <br />HORIZ <br />HORIZONTAL <br />ALUM <br />ALUMINUM <br />HR <br />HOUR <br />ANOD <br />ANODIZED <br />HT <br />HEIGHT <br />APPROX <br />APPROXIMATE <br />HVAC <br />HEATING, VENTILATING <br />APT <br />APARTMENT <br />ANDAIR-CONDITIONING <br />ARCH <br />ARCHITECT, ARCHITECTURAL <br />AUTO <br />AUTOMATIC <br />ID <br />INSIDE DIAMETER <br />AV <br />AUDIO VISUAL <br />INCL <br />INCLUDE, INCLUDING <br />AWP <br />ACOUSTICAL WALL PANEL(S) <br />INFO <br />INFORMATION <br />INSUL <br />INSULATE, INSULATION <br />BB <br />BULLETIN BOARD <br />INT <br />INTERIOR <br />BD <br />BOARD <br />IWD <br />INDIRECT WASTE DRAIN <br />BLDG <br />BUILDING <br />BLKG <br />BLOCKING <br />JAN <br />JANITOR <br />BO <br />BOTTOM OF <br />JT <br />JOINT <br />BOT <br />BOTTOM <br />BRIG <br />BEARING <br />KIT <br />KITCHEN <br />BRZ <br />BRONZE <br />BSMT <br />BASEMENT <br />L <br />LONG <br />BUR <br />BUILT UP ROOFING <br />LAM <br />LAMINATE, LAMINATED <br />LAU <br />LAUNDRY <br />CAB <br />CABINET <br />LAV <br />LAVATORY <br />CB <br />CATCH BASIN <br />LT <br />LIGHT <br />GEM <br />CEMENT, CEMENTITIOUS <br />LTG <br />LIGHTING <br />CER <br />CERAMIC <br />CG <br />CORNER GUARD <br />MAS <br />MASONRY <br />CH <br />COAT HOOK <br />MAIL <br />MATERIAL <br />Cl <br />CAST IRON <br />MAX <br />MAXIMUM <br />CJ <br />CONTROL JOINT <br />MECH <br />MECHANICAL <br />CIP <br />CAST -IN -PLACE <br />MED <br />MEDIUM <br />CL <br />CENTERLINE <br />MEMB <br />MEMBRANE <br />CLG <br />CEILING <br />MEZZ <br />MEZZANINE <br />CLO <br />CLOSET <br />MGT <br />MANAGEMENT <br />CLR <br />CLEAR <br />MFR <br />MANUFACTURER <br />CMU <br />CONCRETE MASONRY UNIT <br />MH <br />MANHOLE <br />CO <br />CLEAN OUT, CASED OPENING <br />MIN <br />MINIMUM, MINUTE <br />COL <br />COLUMN <br />MISC <br />MISCELLANEOUS <br />COMM <br />COMMUNICATION <br />MO <br />MASONRY OPENING <br />CONC <br />CONCRETE <br />MS <br />MOP SINK <br />CONN <br />CONNECTION, CONNECT <br />MTD <br />MOUNTED <br />CONSTR <br />CONSTRUCTION <br />MTL <br />METAL <br />CONT <br />CONTINUOUS, CONTINUE <br />MVBL <br />MOVABLE <br />CORR <br />CORRIDOR <br />CPT <br />CARPET <br />N <br />NORTH <br />CSWK <br />CASEWORK <br />NIC <br />NOT IN CONTACT <br />CTR <br />CENTER <br />NO <br />NUMBER <br />CU <br />CUBIC <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />D <br />DEEP, DEPTH <br />DBL <br />DOUBLE <br />OC <br />ON CENTER <br />DEMO <br />DEMOLISH, DEMOLITION <br />OH <br />OVERHEAD <br />DET <br />DETAIL <br />OD <br />OUTSIDE DIAMETER <br />DF <br />DRINKING FOUNTAIN <br />OPNG <br />OPENING <br />DIA <br />DIAMETER <br />OPP <br />OPPOSITE <br />DIAG <br />DIAGONAL, DIAGRAM <br />ORD <br />OVERFLOW ROOF DRAIN <br />DIM <br />DIMENSION <br />OTS <br />OPEN TO STRUCTURE <br />DIV <br />DIVIDE, DIVISION <br />ABOVE <br />DMPF <br />DAMPPROOF,DAMPPROOFING <br />DN <br />DOWN <br />PBD <br />PARTICLEBOARD <br />DR <br />DOOR, DRESSING ROOM <br />PRCST <br />PRECAST <br />DS <br />DOWNSPOUT <br />PD <br />PLANTER DRAIN <br />DW <br />DISHWASHER <br />PERP <br />PERPENDICULAR <br />DWG <br />DRAWING <br />PLAM <br />PLASTIC LAMINATE <br />DWR <br />DRAWER <br />PLAS <br />PLASTER <br />PLYWD <br />PLYWOOD <br />E <br />EAST <br />PNL <br />PANEL <br />EIFS <br />EXTERIOR INSULATION AND <br />PL <br />PROPERTY LINE <br />FINISH2SYSTEM <br />PR <br />PAIR <br />EJ <br />EXPANSION JOINT <br />PRKG <br />PARKING <br />EL <br />ELEVATION <br />PROP <br />PROPERTY <br />ELEC <br />ELECTRIC, ELECTRICAL <br />PT <br />PAINT, POINT <br />ELEV <br />ELEVATOR <br />PTN <br />PARTITION <br />ENCL <br />ENCLOSE, ENCLOSURE <br />EP <br />ELECTRIC PANEL <br />R <br />RADIUS, RISER <br />EQ <br />EQUAL <br />RCP <br />REFLECTED CEILING PLAN <br />EQUIP <br />EQUIPMENT <br />RD <br />ROOF DRAIN, ROAD <br />ESCAL <br />ESCALATOR <br />REF <br />REFER TO, REFERENCE <br />EXH <br />EXHAUST <br />REF <br />REFRIGERATOR <br />EXP <br />EXPANSION, EXPOSED <br />REINF <br />REINFORCED, REINFORCING <br />EXIST <br />EXISTING <br />REQD <br />REQUIRED <br />REV <br />REVISED, REVISION <br />RFG <br />ROOFING <br />FA <br />FIRE ALARM <br />RM <br />ROOM <br />FCIC <br />FURNISHED BY CONTRACTOR/ <br />RO <br />ROUGH OPENING <br />INSTALLED BY CONTRACTOR <br />RT <br />RIGHT <br />FCIO <br />FURNISHED BY CONTRACTOR/ <br />INSTALLED BY OWNER <br />S <br />SOUTH <br />FD <br />FLOOR DRAIN <br />SAM <br />SELF ADHERING MEMBRANE <br />FDC <br />FIRE DEPARTMENT <br />SC <br />SOLID CORE <br />CONNECTION <br />SCHED <br />SCHEDULE <br />FDTN <br />FOUNDATION <br />SD <br />STORM DRAIN <br />FE <br />FIRE EXTINGUISHER <br />T <br />SECT <br />SECTION <br />FEC <br />FIRE EXTINGUISHER <br />SINGLE <br />CABINET <br />SHT <br />SHEET <br />FH <br />FIRE HYDRANT <br />SHTHG <br />SHEATHING <br />FHC <br />FIRE HOSE CABINET <br />SIM <br />SIMILAR <br />FIG <br />FIGURE <br />SPEC <br />SPECIFICATION <br />FIN <br />FINISH, FINISHED <br />SPKLR <br />SPRINKLER <br />FLEX <br />FLEXIBLE <br />FUR <br />FLOOR, FLOORING <br />SPKR <br />SPEAKER <br />FLUOR <br />FLUORESCENT <br />SQ <br />SQUARE <br />FO <br />FACE OF, FINISHED OPENING <br />SS <br />SERVICE SINK <br />FOIC <br />FURNISHED BY OWNER/ <br />SST <br />STAINLESS STEEL <br />INSTALLED BY CONTRACTOR <br />STC <br />SOUND TRANSMISSION CLASS <br />FOIO <br />FURNISHED BY OWNER/ <br />STD <br />STANDARD <br />INSTALLED BY OWNER <br />STSTD <br />STEEL <br />FP <br />FIRE PROTECTION, FIREPROOF <br />OR <br />STORAGE <br />FR <br />FRAME, FIRE RATED <br />STRUCT <br />STRUCTURAL <br />FRMG <br />FRAMING <br />SUSP <br />SUSPENDED <br />FRPF <br />FIREPROOF, FIREPROOFING <br />FRT <br />FIRE RETARDANT TREATED <br />T <br />TREAD <br />FS <br />FLOOR SINK <br />T&G <br />TONGUE AND GROOVE <br />FT <br />FOOT, FEET <br />TEL <br />TELEPHONE <br />FTG <br />FOOTING <br />TEMP <br />TEMPERATURE, TEMPORARY <br />FUT <br />FUTURE <br />TER <br />TERRAllO <br />FVC <br />FIRE HOSE VALVE CABINET <br />THK <br />THICK, THICKNESS <br />FWC <br />FABRIC WALL COVERING <br />TMPD <br />TEMPERED <br />FWP <br />FABRIC WRAPPED PANEL(S) <br />TO <br />TOP OF <br />TSTAT <br />THERMOSTAT <br />GA <br />GAGE <br />TV <br />TELEVISION <br />GALV <br />GALVANIZED <br />TYP <br />TYPICAL <br />GEN <br />GENERAL, GENERATOR <br />GFRC <br />GLASS -FIBER <br />UGND <br />UNDERGROUND <br />REINFORCED CONCRETE <br />UNFIN <br />UNFINISHED <br />GFRG <br />GLASS -FIBER <br />LION <br />UNLESS OTHERWISE NOTED <br />REINFORCED GYPSUM <br />GFRP <br />GLASS -FIBER <br />VERT <br />VERTICAL <br />REINFORCED PLASTIC <br />VEST <br />VESTIBULE <br />GL <br />GLASS <br />VIF <br />VERIFY IN FIELD <br />GYP <br />GYPSUM <br />VNR <br />VENEER <br />GYP BD <br />GYPSUM BOARD <br />VR <br />VAPOR RETARDER <br />VWC <br />VINYL WALLCOVERING <br />W <br />WEST, WIDE <br />WI <br />WITH <br />W/o <br />WITHOUT <br />WC <br />WATER CLOSET, WALLCOVERING <br />WD <br />WOOD <br />WH <br />WALL HYDRANT <br />WP <br />WEATHERPROOF,WATERPROOF, <br />WATERPROOFING, WORK POINT <br />WR <br />WATER RESISTANT <br />WT <br />WEIGHT 4 <br />WWF <br />WELDED WIRE FABRIC <br />XFMR TRANSFORMER <br />REFERENCE SYMBOLS <br />SECTION <br />XX <br />A-XXX A-XXX <br />SHEET NUMBER <br />BUILDING SECTION INDICATOR <br />SECTION <br />A-XXX <br />SHEET NUMBER <br />WALL SECTION INDICATOR <br />DETAIL <br />XX <br />A-XXX <br />SHEET NUMBER <br />SECTION DETAIL INDICATOR <br />DETAIL <br />A - <br />SHEET NUMBER <br />DETAIL INDICATOR <br />ELEVATION <br />XX <br />I : <br />A-XXX <br />SHEET NUMBER <br />EXTERIOR ELEVATION INDICATOR <br />ELEVATION <br />SHEET NUMBER <br />X-XXX <br />INTERIOR ELEVATION INDICATOR <br />MATCH LINE <br />SEE XX/A-M <br />MATCHLINE INDICATOR <br />x.x x.x <br />NEW COLUMN GRID <br />INDICATED AND GRID LINES <br />X.X X.X <br />NEW GRID INDICATOR AND GRID <br />LINES AT FACE OF FOUNDATION <br />EL 100.00' <br />SPOT ELEVATION INDICATOR <br />DATUM INDICATOR <br />ROOM NAME <br />2022 <br />ROOM NAME AND NUMBER <br />SOUTHPOINT PLAZA - FIRE DAMAGE REPAIR <br />EVERETT, WASHINGTON <br />BUILDING CODE INFORMATION <br />SITE ADDRESS: 10121 EVERGREEN WAY #1, EVERETT, WA <br />LEASE AREA: 2,318 SF SINGLE LEVEL (EXISTING) <br />APPLICABLE CODES: <br />BUILDING CODE: <br />2018 INTERNATIONAL EXISTING BUILDING CODE (IBC) <br />MECHANICAL CODE: <br />2018 INTERNATIONAL MECHANICAL CODE (IMC) <br />FIRE CODE: <br />2018 INTERNATIONAL FIRE CODE (IFC) <br />ENERGY CODE: <br />2018 WASHINGTON STATE ENERGY CODE (WSEC) <br />PLUMBING CODE: <br />2018 UNIFORM PLUMBING CODE (UPC <br />ELECTRICAL CODE: <br />2020 NATIONAL ELECTRIC CODE (NFPA 70) <br />OCCUPANCY GROUP: M <br />CONSTRUCTION TYPE: V-B <br />SPRINKLERED: NO (NONE EXISTING) <br />FIRE ALARM SYSTEM: NO (NONE EXISTING) <br />SITE PLAN <br />I:IIIIIIIIIIIIIIIIIIIIIIIIIII MINE <br />Y <br />4,200 sf <br />a <br />oursaeK <br />a <br />Mattress <br />a <br />Center <br />SW EVERETT MALL WAY <br />PROJECT SITE <br />DRAWING INDEX <br />ARCHITECTURAL <br />ARCHITECTURAL <br />GENERAL INFORMATION <br />A-001 <br />EGRESS PLAN <br />A-101 <br />DEMO FLOOR PLAN <br />A-103 <br />FLOOR PLAN <br />A-104 <br />CEILING PLAN <br />A-105 <br />ROOF PLAN <br />A-201 <br />EXTERIOR ELEVATIONS <br />A-401 <br />ENLARGED PLANS - RESTROOM <br />A-501 <br />EXTERIOR DETAILS <br />A-601 <br />DOOR SCHEDULES <br />A-801 <br />DETAILS <br />STRUCTURAL <br />n 7 <br />GENERAL NOTES <br />S-002 <br />GENERAL NOTES <br />S-003 <br />GENERAL NOTES <br />S-101 <br />FOUNDATION PLANTLOOR PLAN <br />S-102 <br />ROOF FRAMING PLAN <br />S-501 <br />DETAILS <br />S-502 <br />DETAILS <br />MECHANICAL <br />I01U.T-- HVAC LEGEND, SCHEDULES <br />MD1.1 DEMOLITION ROOF PLAN <br />M1.1 HVAC ROOF PLAN <br />PLUMBING <br />PIf1 PLUMBING LEGEND, SCHEDULES, DETAILS <br />P0.2 PLUMBING SCHEDULES <br />P1.1 PLUMBING PLANS <br />P2.1 PLUMBING RISER DIAGRAMS <br />ELECTRICAL <br />EU.T— ELECTRICAL SYMBOLS AND ABBREVIATIONS <br />E0.2 ELECTRICAL SPECIFICATIONS <br />E0.3 ELECTRICAL SCHEDULES <br />E3.1 ELECTRICAL FLOOR PLAN <br />E8.1 ELECTRICAL ONE LINE DIAGRAM <br />PROJECT DIRECTORY <br />OWNER: <br />ROIC <br />11250 EL CAMINO REAL, SUITE 200 <br />SAN DIEGO, CA 92130 <br />PHONE: (858) 255-4920 <br />CONTACT: ROBERT DORAN <br />EMAIL: RDORAN@ROIREIT.NET <br />GENERAL CONTRACTOR: <br />SELECT CONTRACTING <br />PHONE: 206-419-8871 <br />CONTACTNIKEJOHNSON <br />EMAIL: selectcontracting@comcast.net <br />ARCHITECT: <br />SDH ARCHITECT, LLC <br />2242 NW RESERVE CAMP CT <br />BEND, OR 97703 <br />PHONE: 206-369-8881 <br />CONTACT: SCOTT HARRIS <br />EMAIL:SCOTT.HARRIS@SDHARCHITECT.COM <br />STRUCTURAL: <br />AUE <br />PHONE: 425-614-5078 <br />CONTACT: ALEX HABLISTON <br />EMAIL:ALEXH AU-ENG.COM <br />MECHANICAUPLUMBINGIELECTRICAL ENGINEER: <br />METRIX ENGINEERS <br />PHONE: 206-920-9240 <br />CONTACT: SCOTT MILLER <br />EMAIL:SCOTTM@METRIXENG.COM <br />GENERAL NOTES <br />1. DO NOT SCALE THE DRAWINGS. <br />2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE <br />WORK. <br />3. THE CONTRACT DOCUMENT ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE <br />SHALL BE BINDING IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL <br />PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE <br />ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. <br />4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS <br />OTHERWISE INDICATED. <br />5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE <br />LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE <br />OF THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER DOORS AND <br />CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTIONS. <br />6. ALL ANGLED WALLS ARE 45°, 90° OR 135° UON. <br />7. ALL WOOD BACKERS AND NAILERS SHALL BE FIRE RETARDANT. <br />SCOPE OF WORK <br />STRUCTURAL REPAIR OF AN EXISTING COMMERCIAL BUILDING <br />DAMAGED BY FIRE. REPLACEMENT OF DAMAGED PORTION OF <br />STRUCTURE FROM FIRE, WITH NEW STRUCTURAL, LIKE FOR LIKE. <br />NEW HVAC UNITS TO REPLACE DAMAGED UNITS, LIKE FOR LIKE. <br />REPLACEMENT OF STOREFRONT, LIKE FOR LIKE. NO CHANGE IN USE <br />OR OCCUPANCY. <br />TENANT BUILD OUT AND OCCUPANCY BY OTHERS UNDER SEPARATE <br />PERMIT. <br />SDH Architect <br />2242 NW RESERVE CAMP CT <br />BEND, OR 97703 <br />206.369.8881 <br />OWNER <br />ROIC of WASHINGTON <br />8905 Towne Center Drive, Suite 108 <br />San Diego, CA 92122 <br />CONSULTANT <br />SEAL <br />V197219 <br />RLGISTERED <br />ARCHITECT <br />SCOTT DAVID HARRIS <br />STATE OF WASHINGTON <br />SOUTHPOINT PLAZA <br />SUITE 1 - REPAIR <br />10121 EVERGREEN WAY #1 <br />EVERETT, WA <br />ISSUED / REVISED DATE <br />PERMIT SET 06.26.23 <br />PR 01-SOCCER POST 01.26.24 <br />PR 02 06.24.24 <br />PR-01 SOCCER POST 01.26.24 <br />GENERAL <br />INFORMATION <br />A-000 <br />