Laserfiche WebLink
F <br />E <br />D <br />R <br />A <br />1 2 <br />METAL STUDS (PER ES REPORT ESR-2054), <br />c� ¢ o <br />MAXIMUM HEIGHT 20'.0" <br />Z ~or- <br />L LLI <br />FINISH MATERIALS VARY (MAXIMUM <br />¢ CIO <br />WEIGHTEQUAL TO 2 LAYERS <br />o <br />0 o W <br />GYPSUM BOARD EACH SIDE PLUS <br />J <br />APPLIED FINISHES) <br />o <br />FASTENERS: <br />AT PLYWOOD FLOOR (MINIMUM 3/4" CDX): <br />Z a m <br />o¢w� <br />PROVIDE (2) NO 8 X V WOOD SCREWS AT 24" <br />Z o <br />MAXIMUM OC STAGGERED FOR 1 LAYER <br />C <br />GYPSUM BOARD EACH SIDE, 16" MAXIMIM OC <br />Z o <br />STAGGERED FOR 2 LAYERS GYPSUM BOARD <br />Cl-0 Z <br />m <br />EACH SIDE <br />J <br />UQ <br />C-5 _U <br />Z <br />J Cn d <br />AT CIP CONCRETE AND POST -TENSIONED <br />o <br />CONCRETE FLOOR: <br />a�WC> <br />PROVIDE HILTI X-U 0.157" DIAMETER <br />POWDER -ACTUATED FASTENERS, EMBED 3/4" <br />PER ESR-2269.24" MAXIMUM OC STAGGERED <br />FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" <br />W <br />MAXIMUM OC STAGGERED FOR 2 LAYERS <br />N GYPSUM BOARD EACH SIDE <br />PARTITION TO FLOOR CONNECTION <br />FOR SEISMIC SITUATIONS <br />El <br />SCALE: T=1'-O" <br />EXISTING ROOF DECK <br />BLOCKING <br />NECESSARY FOR <br />ATTACHMENT OF <br />FINISHES <br />PARTITION ATTACHED <br />TO 2X STRUCTURE OR <br />GENERAL NOTE: BLOCKING SPANNING <br />MAINTAIN DEFLECTION BETWEEN <br />CAPACITY AND STRUCTURAL MEMBER <br />FIRE -RATING AT ALL <br />STRUCTURAL FIRE -RATED JOINT <br />MEMBERS ASSEMBLY CONSISTING <br />OF OFFSET -LEG TOP <br />TRACK, OVERLAPPING <br />GYPSUM BOARD, AND <br />FASTENERS SEALANT. (NUMBER OF <br />TYPICAL PER GYPSUM BOARD <br />DETAIL LAYERS VARIES PER <br />DESIGN) <br />G <br />SECTION ACROSS PARTITIONS OB SECTION ACROSS SHAFT WALL PARTITIONS O VIEW ALONG PARTITION <br />1HR, 2HR, AND 3HR FIRE -RATINGS, 1HR, 2HR, AND 3HR FIRE -RATINGS, <br />CONSTRUCT PER UL DESIGN HW-D-0060 CONSTRUCT PER UL DESIGN HW-D-0119 OR HW-D-0120 <br />INTERSECTION OF FIRE -RATED PARTITIONS WITH STRUCTURE <br />3 <br />0 <br />z <br />0 <br />=� <br />LU <br />�o <br />V1 L" W <br />W W r=1 <br />CS, LTC <br />� <br />W <br />4 5 <br />C7 C1 Cl C1 C1 C1 Cl <br />1-801 A-801 k YA-801 A-801 A-801 YA-801 k A-801 <br />1 1 <br />X <br />O \ O <br />nHTIAL-HT Z ION FOR PARTIAL HT <br />C3 FRAMING, WITH BRACING <br />_ <br />O Z <br />'. W <br />ot� LU � <br />LU <br />O <br />Z <br />W <br />NI L <br />0 <br />NZ Z �Z Z �Z <br />Z <br />z= z= z= z= o <br />U <br />0 0 0 LU <br />(PA -W <br />A B Cl I D E LFP <br />NON -FIRE RATED NON -FIRE RATED NON -FIRE RATED NON -FIRE RATED NON -FIRE RATED PARTI 1101 FIRE PARTITION <br />FULL -HEIGHT PARTITION FULL -HEIGHT PARTITION PARTITION WITH FULL -HEIGHT PARTITION WITH PARTIAL -HEIGHT CONSTRUCT <br />PARTIAL -HEIGHT FINISH FINISH MATERIALS <br />MATERIALS <br />PARTITIONMALL DESIGNATIONS <br />SCALE: NOT TO SCALE <br />SCALE: 3 44' <br />3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT <br />FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END <br />IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. <br />HANGAR WIRE AT EACH <br />PERIMETER MAIN TEE AND <br />PERIMETER CROSS TEE <br />2" X 2" SHEET METAL ANGLE <br />GRID -TYPE SUSPENSION <br />8" MAX <br />OA PERIMETER SUPPORT <br />FASTEN TO STRUCTURE PER ESR-1222 <br />SECTION 4.2 AND IN ACCORDANCE WITH <br />CHAPTER 13.3 OF ASCE 7-10 <br />12 GAGE MINIMUM HANGER WIRE, <br />AT 4'-0" OC EACH DIRECTION - <br />NO MORE THAN 1:6 <br />OUT -OF -PLUMB, TYPICAL <br />WIRE LOOPED AND WRAPPED <br />AROUND ITSELF 3 TIMES MINIMUM <br />AT EACH END OF HANGER WIRE <br />WITHIN 3" MAXIMUM LENGTH <br />EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS <br />OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE <br />PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND <br />BRACED FROM STRUCTURE <br />WHERE HANGER WIRES ARE <br />MORE THAN 1:6 <br />OUT -OF -PLUMB, PROVIDE <br />COUNTER -SLOPING WIRE 00 <br />TRAPEZE AS NECESSARY TO a <br />AVOID OBSTRUCTIONS <br />MAINTAIN HANGER WIRE SPACING AND <br />CAPACITY BELOW OBSTRUCTION <br />6 <br />o � <br />O <br />� W <br />Z <br />IJW O <br />gym¢ <br />ED U, tt� <br />c= C <br />z U_ <br />O U <br />W <br />L '\ <br />_ <br />Q <br />L U V . <br />LLA O <br />O <br />oQo <br />W_ <br />LU=o <br />U <br />__ <br />Cf) <br />pg O W_ <br />W <br />li Z Z <br />ERE CEILING OCCURS, EXTEND FINISH MATERIALS 12" ABOVE CEILING, TYP <br />RAND SUPPORTING STRUCTURE SHOWN SCHEMATICALLY, SEE DETAILS FOR ACTUAL CONFIGURATION, TYP <br />)VIDE INSULATION ONLY WHERE INDICATED BY PARTITION -TYPE INDICATOR <br />0 <br />CUT GYPSUM BOARD ADD SOLID 2X <br />TIGHT TO STRUCTURE BLOCKING FOR WIDTH <br />OF PARTITION <br />FOR ITEMS NOT <br />NOTED OR <br />DIMENSIONED <br />SEE <br />A <br />OD SHAFT WALL PARTITION LOCATED AT SLAB EDGE/OPENING <br />LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS <br />SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) <br />12 GAGE TAUT OR SLACK WIRE _ <br />LIGHT FIXTURES WEIGHING MORE THAN <br />10 POUNDS AND LESS THAN 56 POUNDS, <br />AND AIR TERMINALS/SERVICES <br />WEIGHING MORE THAN 20 POUNDS AND <br />LESS THAN 56 POUNDS SHALL BE <br />CONNECTED TO STRUCTURE ABOVFAP� <br />(2)12 GAGE TAUT OR SLACK WIRES <br />ATTACHED AT DIAGONAL CORNERS <br />7 <br />8 <br />1 :1 3 5/8" METAL STUDS @ 16" OC <br />5/8" GYPSUM BOARD <br />EACH SIDE 2 6" METAL STUDS @ 16" OC <br />METALSTUDS <br />INSULATION IF NOTED 3 <br />4 21/2" METAL STUDS @ 16" OC <br />5/8" GYPSUM BOARD <br />5 3 518" METAL STUDS @ 16" OC <br />METALSTUDS <br />INSULATION IF NOTED 6 6" METAL STUDS <br />60OS137-33 @ 16' OC <br />1 HR FIRE -RATED <br />CONSTRUCT PER 7 3 5/8" METAL STUDS @ 16" OC <br />UL DESIGN NO. U419 <br />METALSTUDS 8 6" METAL STUDS @ 16" OC <br />5/8"TYPE "X" GYPSUM <br />BOARD EACH SIDE 9 <br />INSULATION IF NOTED <br />2 HR FIRE -RATED <br />CONSTRUCT PER <br />1 110 1 3 5/8" METAL STUDS @ 16" OC <br />UL DESIGN N0. U419 <br />- METAL STUDS <br />11 6" METAL STUDS @ 16" OC <br />- 2 LAYERS 518' TYPE T GYPSUM <br />BOARD EACH SIDE, STAGGERED <br />12 <br />- INSULATION IF NOTED <br />PARTITION -SIZE <br />LEGEND <br />SCALEATS <br />h <br />FOR WALLS TO 10'-0" - BRACE WITH <br />362S137-33 AT V-0" MAXIMUM OC <br />AND AT EACH WALL END. <br />ALTERNATE DIRECTION OF <br />BRACES ALONG LENGTH OF WALL <br />WHERE POSSIBLE. <br />FOR WALLS TO 16-0" - BRACE WITH <br />DOUBLED 362S137-33 AT 8'-0" <br />MAXIMUM OC AND AT EACH WALL <br />END. ALTERNATE DIRECTION OF <br />BRACES ALONG LENGTH OF WALL. <br />FASTEN DOUBLED STUDS <br />TOGETHER WITH NO 8 SCREWS AT <br />24" MAXIMUM OC. <br />l A) SECTION ACROSS PARTITION <br />FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 <br />DEGREES (IN PLAN) FROM EACH OTHER AND <br />SECURED TO MAIN RUNNER WITHIN 2" OF <br />INTERSECTION. EACH END OF EACH WIRE TO <br />BE LOOPED AND WRAPPED AROUND ITSELF <br />TIMES MINIMUM WITHIN A 3" MAX LENGTH <br />LIGHT FIXTURES AND AIR <br />TERMINALS/SERVICES WEIGHING MC <br />56 POUNDS AND ALL PENDANT LIGHT <br />SHALL BE SUPPORTED DIRECTLY FRI <br />STRUCTURE ABOVE USING APPROVE <br />HANGARS <br />TOP OF PARTITION WHERE BRA <br />SCALE: T=1'-0" <br />FOR SPANS UP TO 6-0", USE A SINGLE 20 GAGE 15/8" <br />COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 <br />518" GYPSUM BOARD LIGHT FIXTURES, AIR TERMINALS, AND <br />SERVICES SHALL BE POSITIVELY LOCATE BRACING AT 12'-0" OC EACH SCREWS AND TO STRUCTURE WITH (2) HILTI X-DNI.145 DIA X <br />314" <br />ATTACHED TO THE CEILING SYSTEM DIRECTION AND WITHIN 6'-0" OF PERIMETER <br />GYPSUM BOARD CONSTRUCTION SHALL COMPLY WITH ADDITIONAL PROVISIONS OF IBC SECTION 2508. WALLS, PARTITIONS, OR EXPANSION JOINTS FOR SPANS UP TO 9'-0", USE DOUBLE COMPRESSION STRUT <br />METAL SUSPENSION SYSTEM SHALL CONFORM WITH ASCE 7, SECTION 13.5.6.2.1, ASTM C635, ASTM C636, ASTM C754, AND CISCA 3-4. <br />O GENERAL SUPPORT O LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT O <br />NOT REQUIRED IN SEISMIC DESIGN CATAGORY C <br />FOR CEILINGS LESS THAN 144 SF BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 <br />INSTALLATION OF SUSPENDED GYP BD CEILING - IBC SEISMIC CATEGORY C, D, E, F <br />3" X 3" X 3" ANGLE (20 <br />GAGE MINIMUM), a <br />FASTENED TO TRACK <br />AND BRACED PER bc <br />DETAIL AT RIGHT <br />20 GAGE MINIMUM <br />DEEP LEG TRACK OR <br />SLOTTED TRACK <br />METAL STUDS, CUT <br />3/4" SHORT FOR 3/4" <br />DEFLECTION <br />Er <br />FINISH MATERIALS VARY <br />(MAXIMUM WEIGHT EQUAL <br />TO 2 LAYERS GYPSUM <br />BOARD EACH SIDE PLUS <br />APPLIED FINISHES) <br />9 10 <br />THE PARTITION -TYPE DESIGNATION OR <br />WALL -TYPE DESIGNATION IS A THREE -UNIT <br />CODE THAT INDICATES THE CONFIGURATION, <br />CONSTRUCTION AND INSULATION OF THE <br />PARTITION AS FOLLOWS: <br />INSULATION (PER THIS DETAIL, BELOW) <br />CONSTRUCTION OF PARTITIONMALL <br />VERTICAL CONFIGURATION OF <br />PARTITIONMALL <br />]ON/WALLSYMBOLOGY <br />— NO INSULATION <br />a BATT ACOUSTICAL <br />INSULATION <br />t BATT THERMAL <br />INSULATION <br />INSULATION DESIGNATION <br />NOTE: SEE SPECIFICATION FOR STUD SPACING AND GAGE <br />q PARTITION -TYPE LEGEND <br />E" SCALE: NTS <br />A <br />I AT SINGLE BRACE - FASTEN ANGLE TO <br />BRACE WITH (4) NO 10 SCREWS <br />AT DOUBLE BRACE - FASTEN DOUBLE <br />BRACE TO BOTH ANGLES WITH (6) NO <br />10 SCREWS THROUGH BRACE AND <br />BOTH ANGLES <br />OSECTION ACROSS BRACING <br />CED TO STRUCTURE ABOVE - SEISMIC <br />PROVIDE CEILING EXPANSION <br />JOINTS AS NECESSARY, <br />DIVIDING CEILING INTO AREAS <br />NO GREATER THAN 2500 SF <br />8" MAX EACH SIDE <br />O EXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF <br />NOT REQUIRED IN SEISMIC DESIGN CATAGORY C <br />AT SINGLE BRACE - FASTEN <br />ANGLE TO TRACK WITH (8) NO 10 <br />SCREWS <br />AT DOUBLE BRACE - FASTEN (2) <br />ANGLES TO TRACK WITH (8) NO 10 <br />SCREWS AT EACH ANGLE <br />SEISMIC DESIGN CATEGORY C: <br />PROVIDE FLEXIBLE CONNECTION TO <br />SPRINKLER HEAD THAT ALLOWS CEILING <br />TO MOVE 3/8" IN ALL HORIZONTAL <br />DIRECTIONS <br />SEISMIC DESIGN CATEGORY D, E, AND F: <br />PROVIDE FLEXIBLE CONNECTION TO <br />SPRINKLER HEAD THAT ALLOWS CEILING <br />TO MOVE 1" IN ALL HORIZONTAL <br />DIRECTIONS <br />O SPRINKLER HEAD CLEARENCE <br />DESIGN ARCHITECT <br />SDH Architect <br />2242 NW RESERVE CAMP CT <br />BEND, OR 97703 <br />206.369.8881 <br />OWNER <br />ROIC <br />ROIC of WASHINGTON <br />8905 Towne Center Drive, Suite 108 <br />San Diego, CA 92122 <br />CONSULTANT <br />SEAL <br />:I;TERED <br />AFkCHI T LCT <br />SCOTT DAVID HARRIS <br />STATE OF WASHINGTON <br />SOUTHPOINT PLAZA <br />SUITE 1 - REPAIR <br />10121 EVERGREEN WAY #1 <br />EVERETT, WA <br />ISSUED / REVISED <br />DATE <br />PERMIT SET <br />06.26.23 <br />PERMIT COMMENTS 1 <br />07.31.23 <br />PR 01-SOCCER POST <br />01.26.24 <br />PR-01 SOCCER POST 01.26.24 <br />DETAILS <br />SCALE: NOT TO SCALE <br />A-801 <br />