F <br />E <br />D <br />C <br />S <br />A <br />z <br />DESIGN CODES AND LOADING: <br />INTERNATIONAL BUILDING CODE (2018 EDITION) <br />LIVE LOADS: <br />*20 PSF - ROOF <br />* INDICATES LIVE LOAD REDUCTION USED IN DESIGN PER IBC 1607 <br />REFER TO IBC TABLE 1607.1 FOR RELEVANT CONCENTRATED LIVE LOADS <br />SNOW LOADS: <br />25 P5F = P - GROUND SNOW LOAD <br />AT BUILDIN3 ROOF: <br />25 PSF = P - FLAT ROOF SNOW LOAD <br />1.00 = Ce - fXXPOSURE FACTOR <br />1.00 = Ct - THERMAL FACTOR <br />1.00 = Is - SNOW IMPORTANCE FACTOR <br />1.00 = CS - SLOPE FACTOR <br />WIND DE51GN: <br />q8 MPH = V - BASIC DESIGN WIND SPEED <br />76 MPH = Vggp= V * 4(0.6), ALLOWABLE STRESS DE51GN WIND SPEED <br />II = RISK CATEGORY <br />B = EXPOSURE CATEGORY <br />1.00 = Kt- TOPOGRAPHIC FACTOR <br />± 0.16 = GC .- INTERNAL PRESSURE COEFFICIENT <br />pi <br />SEISMIC DESIGN: <br />1.384 = 55 - MAPPED SPECTRAL RESPONSE COEFFICIENT (SHORT PERIOD) <br />0.492 = 51 - MAPPED SPECTRAL RESPONSE COEFFICIENT (1-5ECOND PERIOD) <br />1.107 = SDS DESIGN SPECTRAL RESPONSE COEFFICIENT (SHORT PERIOD) <br />NULL = 5 - MAPPED SPECTRAL RESPONSE COEFFICIENT (I -SECOND PERIOD) <br />D (DEFAULT) = SEISMIC SOIL SITE CLA55 <br />D = SEISMIC DE51GN CATEGORY <br />II = RISK CATEGORY <br />1.0 = le - SEISMIC IMPORTANCE FACTOR <br />BEARING WALL SYSTEM: LIGHT FRAMED WOOD SHEAR WALLS = VERTICAL SEISMIC FORCE RESISTING SYSTEM <br />WOOD DIAPHRAGM FOR ROOFS t FLOORS = HORIZONTAL SEI5MIC FORCE RE515TING SYSTEM <br />2.0 = R, RESPONSE MODIFICATION COEFFICIENT <br />0.55 = C51 SEISMIC RESPONSE COEFFICIENT <br />3 4 5 6 <br />SOILS AND FOUNDATIONS (PRESUMPTIVE): <br />ALL 501L CRITERIA MUST BE VERIFIED IN THE FIELD TO BE CLASS OF MATERIAL 4$4 (EXCLUDING UNIFIED SOIL CLASSIFICATIONS SM-50 B SC) <br />OR BETTER PER IBC TABLE 1606.2. <br />GENERAL: <br />THE INTERNATIONAL BUILDING CODE (IBC) AND STANDARDS SHALL GOVERN ALL MATERIALS AND WORKMANSHIP. <br />ALL TEMPORARY SHORING OR BRACING 15 THE RESPONSIBILITY OF THE CONTRACTOR. THE DRAWINGS REFLECT THE FINAL FINISHED CONDITION <br />OF THE STRUCTURE. <br />THESE DRAWINGS ARE NOT INTENDED TO SHOW EACH AND EVERY CONDITION BUT TO INDICATE THE GENERAL CONSTRUCTION. WHERE <br />CONDITIONS ARE NOT SPECIFICALLY DETAILED, 51MILAR CONDITIONS SHALL BE USED AT THE DISCRETION AND APPROVAL OF THE ARCHITECT <br />AND ENGINEER. <br />THE CONTRACTOR 15 RESPONSIBLE FOR ALL JOB SITE SAFETY AS WELL AS ALL MEANS, METHODS, AND SEQUENCES OF CONSTRUCTION TO <br />SAFELY PERFORM THE WORK. AUE HAS NO EXPERTISE IN NOR HAS BEEN RETAINED TO PROVIDE REVIEW OF THE CONTRACTORS' SAFETY <br />PRECAUTIONS AS THEY RELATE TO THE CONSTRUCTION OF THIS PROJECT. <br />IF ANY ERROR OR OMISSION APPEARS IN THESE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE <br />OWNER AND STRUCTURAL ENGINEER OF RECORD IN WRITING OF SUCH OMISSION OR ERROR BEFORE PROCEEDING WITH THE WORK OR ACCEPT <br />FULL RESPONSIBILITY FOR THE COST TO RECTIFY SAME. VERIFY AND COORDINATE OPENINGS IN FLOORS, WALLS, AND ROOF WITH <br />ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. <br />THE ARCHITECTURAL DRAWINGS SHALL BE REFERENCED FOR WALLS, FINISHES AND DIMENSIONS. DIMENSIONS PROVIDED ON THE STRUCTURAL <br />DRAWINGS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY THE ARCHITECTURAL DRAWINGS. <br />WHERE ©ENGINEER APPROVED ALTERNATE" IS SPECIFIED HEREIN, AN ALTERNATE PRODUCT OF EQUAL OR GREATER STRENGTH AND SIMILAR IN <br />NATURE, DURABILITY, AND FORM MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION TO THE STRUCTURAL ENGINEER OF RECORD <br />(EOR) FOR REVIEW. NO ALTERNATE PRODUCTS MAY BE USED PRIOR TO THE APPROVAL OF THE EOR. ALTERNATE PRODUCTS THAT ARE <br />SUBMITTED WITHOUT ADEQUATE DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DE51GH INTENT OF THE ORIGINALLY SPECIFIED <br />PRODUCT WILL BE REJECTED. <br />DRAWINGS ARE NOT TO BE SCALED. <br />SHOP DRAWINGS: <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE GENERAL CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER OF RECORD. SHOP DRAWINGS REVIEWED BY THE GENERAL CONTRACTOR SHALL INCLUDE A REVIEW STAMP FROM THE GENERAL <br />CONTRACTOR INDICATING THEIR REVIEW HA5 BEEN COMPLETED, <br />THE STRUCTURAL ENGINEER OF RECORD'S SHOP DRAWING REVIEW 15 ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS AND <br />DOES NOT INDICATE THE SHOP DRAWINGS ARE CORRECT OR COMPLETE. THI5 15 THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />ANY CHANGES OR DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS CONTAINED WITHIN THE SHOP DRAWINGS SHALL BE CLOUDED AND NOTED <br />AS SUCH, THE STRUCTURAL ENGINEER OF RECORD'S SHOP DRAWING APPROVAL SHALL NOT BE CONSIDERED AN APPROVAL OF ANY DESIGN <br />DEVIATIONS UNLESS SPECIFICALLY NOTED AS SUCH, SHOP DRAWINGS DO NOT SUPERSEDE OR REPLACE THE CONSTRUCTION DOCUMENTS. <br />THE SHOP DRAWINGS SHALL BE SUBMITTED t REVIEWED BY THE ARCHITECT t STRUCTURAL ENGINEER OF RECORD BEFORE PROCEEDING WITH <br />FABRICATION. THE GENERAL CONTRACTOR SHALL ALLOW 10 WORKING DAYS MINIMUM FOR THE STRUCTURAL ENGINEER OF RECORD TO COMPLETE <br />THEIR REVIEW. THE STRUCTURAL ENGINEER OF RECORD WILL REVIEW ONE SUBMITTAL FOR EACH LISTED SHOP DRAWING. SHOP DRAWINGS THAT <br />REQUIRE MULTIPLE REVIEWS BY THE STRUCTURAL ENGINEER OF RECORD DUE TO ERRORS t INCOMPLETENESS WILL BE AT THE EXPENSE OF THE <br />GENERAL CONTRACTOR. <br />LIST OF REQUIRED SHOP DRAWINGS: <br />CONCRETE MIX DESIGN(5) <br />REINFORCING STEEL FOR CONCRETE $ MASONRY CONSTRUCTION <br />STRUCTURAL STEEL <br />GLUE LAMINATED MEMBERS <br />DESIGN SOIL VALUES: <br />1500 PSF = ALLOWABLE VERTICAL 501L BEARING PRESSURE (PRESUMPTIVE, IBC 1806.2) <br />0.25 = ALLOWABLE 501L FRICTION COEFFICIENT (PRESUMPTIVE, IBC 1806.2) <br />150 P5F/FT = PASSIVE EARTH PRESSURE (IBC 1806.2) <br />45 P5F/FT = ACTIVE EARTH PRESSURE (UNRESTRAINED) (IBC 1610.1) <br />60 PSF/FT = AT -REST EARTH PRESSURE (RESTRAINED) (IBC 1610.1) <br />120 PCF = ASSUMED SOIL DENSITY <br />ALL FOOTING DIMENSIONS ARE MINIMUMS. <br />ALL FOUNDATIONS SHALL REST ON EITHER COMPACTED STRUCTURAL FILL OR COMPETENT NATIVE SOIL <br />ALL EXTERIOR FOUNDATIONS SHALL BEAR NOT LESS THAN THE MINIMUM SPECIFIED DISTANCE BELOW ADJACENT GRADE AS NOTED WITHIN THE <br />STRUCTURAL PLANS. <br />ALL SLABS ON GRADE SHALL BE PLACED ON A PREPARED BASE COURSE. THE BASE COURSE SHALL CONSIST OF COMPACTED CRUSHED <br />AGGREGATE. REFER TO THE PLANS AND DETAILS FOR OTHER REQUIREMENTS. REFER TO THE ARCHITECT FOR VAPOR BARRIER AND UNDER -SLAB <br />DRAINAGE REQUIREMENTS. <br />SUBGRADE WALLS ARE DESIGNED ASSUMING A "DRAINED" CONDITION, SEE CIVIL AND MECHANICAL DRAWINGS FOR SUBGRADE DRAINAGE SYSTEM. <br />SUBGRADE WALLS SHALL ATTAIN THEIR DE51GN STRENGTH PRIOR TO PLACING BACKFILL. THE CONTRACTOR SHALL PROVIDE TEMPORARY <br />BRACES FOR WALLS IF BACKFILL 15 PLACED BEFORE WALLS AND SLABS ACHIEVE THEIR DESIGN STRENGTH OR IF WALL RELIES ON UPPER SLAB <br />FOR SUPPORT. <br />REINFORCED CONCRETE: <br />REFERENCE STANDARDS: <br />• ACI 301-10 "SPECIFICATIONS FOR STRUCTURAL CONCRETE" <br />• ACI 318-14 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE' <br />• ACI 117-10 "SPECIFICATION FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS" <br />• ACI 306R-16 "GUIDE TO COLD WEATHER CONCRETING" <br />• ACI 305R-16 © GUIDE TO HOT WEATHER CONCRETING' <br />CONCRETE MIX SPECIFICATIONS: <br />FOOTINGS AND FOUNDATION WALLS: <br />- MIN. 28 DAY STRENGTH: 4,500 psi <br />MAX AGGREGATE SIZE: 3/4" DIA. <br />EXPOSURE CLA55: F2 / 50 / WO / Cl <br />- MAX WATER / CEMENT RATIO: 0.45 <br />- AIR CONTENT (+/-1.5%): 6% <br />- MAXIMUM DE51GN SLUMP: 3" (OR B" W/ ADMIXTURES) <br />- % MAX SHRINKAGE AT 28 DAYS: 0.05 <br />NORMAL WEIGHT CONCRETE <br />MATERIALS <br />PORTLAND CEMENT: ASTM C150 TYPE 1/11 OR A5TM C595 TYPE IL <br />FLY ASH OR POZZOLANS: ASTM C616 CLA55 C <br />- MIXING WATER: A5TM C1602 <br />• AGGREGATES <br />NORMAL WEIGHT AGGREGATE SHALL CONFORM TO ASTM C33 <br />- LIGHT WEIGHT AGGREGATE SHALL CONFORM TO A5TM C330 <br />ADMIXTURES <br />AIR ENTRAINMENT ADMIXTURES: ASTM C260 <br />• WATER REDUCING AND SETTING TIME MODIFICATION ADMIXTURES: A5TM C4g4 <br />PRODUCING FLOWABLE CONCRETE ADMIXTURES: ASTM C1017 <br />- OTHER ADMIXTURES NOT SPECIFIED MUST BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW. <br />GENERAL ABBREVIATIONS <br />7 8 9 <br />MIX SPECIFICATION REQUIREMENTS: <br />WHERE AIR CONTENT 15 SPECIFIED IN THE ABOVE CONCRETE MIX SPECIFICATIONS FOR A STRUCTURAL ELEMENT, PROVIDE AIR ENTRAINING <br />ADMIXTURE TO ACHIEVE THE AIR CONTENT PERCENTAGE SPECIFIED, THE TOTAL AIR CONTENT SPECIFIED 15 TO INCLUDE AIR ENTRAINMENT ONLY, <br />ENTRAPPED AIR 15 NOT PERMITTED TO BE USED IN THE TOTAL AIR CONTENT SPECIFIED, AIR CONTENT SPECIFIED 15 BASED ON 3/4" DIAMETER <br />AGGREGATE. IF 3/8" DIAMETER AGGREGATE 15 USED, INCREASE AIR CONTENT BY 1.5%. TESTING SHALL CONFORM TO A5TM C231 AND A5TM CI73. <br />THE AVERAGE OF ALL TESTS SHALL MEET OR EXCEED THE SPECIFIED VALUE, TESTING 15 TO BE PERFORMED AT THE POINT OF DELIVERY. <br />CALCIUM CHLORIDE MAY NOT BE USED. <br />ALL CONCRETE MIX DESIGN SUBMITTALS SHALL INCLUDE PORTLAND CEMENT MILL TE5T5 WITH CERTIFICATES OF COMPLIANCE. <br />MINIMUM TOTAL CEMENTITIOU5 CONTENT SHALL HAVE 5-1/2 SACKS (517 LB) MINIMUM OF CEMENT PER CUBIC YARD, <br />THE USE OF FLY ASH OR POZZOLANS CONFORMING TO THE ASTM LISTED ABOVE SHALL CONFORM TO ACI TABLE 26.4.2.2(b) AND SECTION <br />26.4.2.2. THE MAXIMUM PERCENT OF FLY ASH / OTHER POZZOLANS SHALL BE 25% OF THE TOTAL CEMENTITIOU5 CONTENT UNLESS REVIEWED <br />AND APPROVED OTHERWISE BY THE ENGINEER OF RECORD. <br />THE WATER / CEMENT RATIO SHALL BE BASED ON THE TOTAL CEMENTITIOUS MATERIAL, INCLUDING CEMENT AND POZZOLANS SUCH AS FLY ASH <br />SPECIFIED SHRINKAGE LIMITS SHALL BE VERIFIED IN ACCORDANCE WITH TESTING THAT 15 IN ACCORDANCE WITH ASTM C157. <br />MIX PROPORTIONS SHALL MEET OR EXCEED ALL REQUIREMENTS SPECIFIED. THE MORE STRINGENT OF THE REQUIREMENTS SHALL GOVERN <br />GENERAL REQUIREMENTS: <br />PERFORM CONCRETE WORK, INCLUDING HANDLING, PLACING, AND CONSTRUCTING IN ACCORDANCE WITH ACI 301, INCLUDING ACI 117, UNLESS MORE <br />STRINGENT REQUIREMENTS ARE SPECIFIED. <br />INSTALL AND SECURE EMBEDMENTS SUCH AS ANCHOR RODS AND EMBEDMENT PLATES WITHIN THE SPECIFIED TOLERANCES PRIOR TO CONCRETE <br />PLACEMENT. <br />CONCRETE SHALL BE PROPERLY CONSOLIDATED PER THE LATEST EDITION OF ACI 309 U51NG INTERIOR MECHANICAL VIBRATION, EXCEPT AT <br />CONCRETE SLABS ON GRADE LESS THAN 5" THICK. DO NOT OVER -VIBRATE CONCRETE. <br />PROTECT AND CURE ALL CONCRETE SURFACES, EXCEPT FOOTINGS, FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT IN ANY APPROVED MANNER IN <br />ACCORDANCE WITH ACI 301. <br />WHERE EXISTING CONCRETE ABUTS NEW CONCRETE, ROUGHEN THE EXISTING SURFACE TO A FULL AMPLITUDE OF 1/4 INCH. <br />PROJECTING CORNERS OF SLABS, BEAMS, WALL5, COLUMNS, ETCH SHALL BE FORMED WITH A 3/4" CHAMFER, UNLESS NOTED OTHERWISE. <br />CONCRETE SUPPLIER SHALL COORDINATE EXPECTED WATER VAPOR TRANSMISSION RATES DURING CURING OF THE CONCRETE WITH CONTRACTOR <br />AND ARCHITECT TO ALLOW FOR FLOORING/ROOFING TO BE INSTALLED. <br />FORMWORK t SHORING: <br />ALL FORMWORK AND SHORING SHALL FOLLOW THE RECOMMENDATIONS PROVIDED IN ACI 347. FORMWORK SHALL CONFORM TO ACI 301 SECTION 2. <br />RESHORING FOR EARLY REMOVAL OF ORIGINAL SUPPORTS 15 NOT PERMITTED, <br />ALL SHORING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, FORMWORK SUPPORTS AND SNORING SHALL BE DESIGNED TO PROVIDE <br />FINISHED CONCRETE SURFACES AT ALL FACES. <br />WEATHER CONDITIONS: <br />CONCRETE PLACED WHEN THE AMBIENT AIR TEMPERATURE HA5 FALLEN TO OR 15 EXPECTED TO FALL BELOW 40 deg F DURING THE PROTECTION <br />PERIOD, IMPLEMENT COLD WEATHER PROCEDURES THAT COMPLY WITH ACI 3IB-26.5.4 AND THE PROVISIONS IN ACI 306R. <br />CONCRETE PLACED WHEN THE AMBIENT AIR TEMPERATURE EXCEEDS 80 deg F OR THE RATE OF EVAPORATION 15 GREATER THAN 0.2 P5F PER <br />HOUR, IMPLEMENT HOT WEATHER PROCEDURES THAT COMPLY WITH ACI 315 26.5.5 AND THE PROVISIONS IN ACI 305R. <br />CONCRETE TESTING AND ACCEPTANCE: <br />THE CONCRETE PRODUCTION FACILITY SHALL SUBMIT FOR ENGINEER APPROVAL THE CONCRETE MIX DESIGN PRIOR TO PLACEMENT WHICH <br />INCLUDES STRENGTH TEST RECORDS NOT MORE THAN 24 MONTHS OLD AND CONSISTING OF AT LEAST 30 CONSECUTIVE TESTS OR TWO GROUPS <br />OF CONSECUTIVE TESTS TOTALING AT LEAST 30 TESTS, <br />OBTAIN SAMPLES IN ACCORDANCE WITH ACI 301 SECTION 1.6.4.2. OBTAIN AT LEAST ONE COMPOSITE SAMPLE FOR EACH 100 CUBIC YARDS OR <br />FRACTION THEREOF, OF EACH CONCRETE MIXTURE PLACED IN ONE DAY. <br />MOLD AND CURE A MINIMUM OF FOUR CYLINDERS FROM EACH SAMPLE IN ACCORDANCE WITH ASTM C31. TEST ONE CYLINDER AT 7 DAYS AND <br />TEST TWO CYLINDERS AT 28 DAYS. HOLD ONE CYLINDER IN RESERVE FOR TESTING AS DIRECTED BY THE ENGINEER. <br />A STRENGTH TEST SHALL BE THE AVERAGE OF THE STRENGTHS OF AT LEAST TWO 6 X 12 INCH CYLINDERS MADE FROM THE SAME SAMPLE OF <br />CONCRETE AND TESTED AT THE TEST AGE DESIGNATED. IF 4 X 8 IN CYLINDERS ARE USED, ADDITIONAL CYLINDERS MUST BE CURED FOR <br />TESTING OF 3 CYLINDERS AT THE TEST AGE DESIGNATED. <br />STRENGTH LEVEL OF AN INDIVIDUAL CLASS OF CONCRETE SHALL BE CONSIDERED SATISFACTORY IF BOTH OF THE FOLLOWING REQUIREMENTS <br />ARE MET: <br />- EVERY ARITHMETIC AVERAGE OF ANY THREE CONSECUTIVE STRENGTH TESTS EQUALS OR EXCEEDS f'c <br />NO STRENGTH TEST FALLS BELOW f'c BY MORE THAN 500 PSI. <br />CONCRETE SPECIFIED CLEAR COVER FOR REINFORCING STEEL IS AS FOLLOWS: <br />• FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST EARTH: 3" <br />• FORMED SURFACES IN DIRECT CONTACT WITH EARTH OR WEATHER: 2" FOR #6 - #I8, 1-1/2" FOR UP TO #5 BAR <br />• SLABS, WALL5, AND JOISTS NOT EXPOSED TO EARTH OR WEATHER: 1-112" FOR #14 - #181 3/4" FOR UP TO #II BAR <br />• BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES NOT EXPOSED TO EARTH OR WEATHER: 1-1/2" <br />10 <br />AB, A.B. <br />ANCHOR BOLT <br />CJ, C.J. <br />CONTRACTUAL JOINT <br />EJ, E.J. <br />EXPANSION JOINT <br />GIRD <br />GRADE <br />LVL <br />MICROLLAM BEAM <br />PT, P.T. <br />PRESSURE TREATED <br />T@G <br />TONGUE AND GROOVE <br />ABV, <br />ABOVE <br />CL <br />CENTER LINE <br />EMBED. <br />EMBEDMENT <br />GWB <br />GYPSUM WALL <br />MAS. <br />MASONRY <br />P/T <br />POST TENSIONED <br />THR'D <br />THREADED) <br />ADY L <br />ADDITIONAL <br />CLR <br />CLEAR <br />EL, ELEV. <br />ELEVATION <br />BOARD <br />MAT'L <br />MATERIAL <br />QTY <br />QUANTITY <br />TJ <br />TRUSS JOIST <br />ADJ. <br />ADJACENT <br />CMU <br />CONC. MASONRY UNIT <br />EN, E.N. <br />EDGE NAIL <br />HDR <br />HEADER <br />ME, <br />MACHINE BOLT <br />REF. <br />REFERENCE <br />MACMILLAN <br />ALT. <br />ALTERNATE <br />COL. <br />COLUMN <br />ENG <br />ENGINEER <br />HF, H.F. <br />HEM -FIR <br />(A307) <br />REINF. <br />REINFORCEMENT <br />TMPRY <br />TEMPORARY <br />APPRX. <br />APPROXIMATE <br />CONC. <br />CONCRETE <br />EQ <br />EQUAL <br />HGR <br />HANGER <br />MD <br />MID -DEPTH <br />REQ'D <br />REQUIRED <br />TN T.N. <br />TOE NAIL <br />ARCH <br />ARCHITECTURAL <br />CONN. <br />CONNECT(ION) <br />E5, E.S. <br />EACH SIDE <br />HORZ. <br />HORIZONTAL <br />MRF <br />MOMENT RESISTING <br />RO, R.O. <br />ROUGH OPENING <br />T.O. <br />TOP OF <br />@ <br />AT <br />CON5T. <br />CONSTRUCTION <br />EXIST <br />EXISTING <br />H5B <br />HIGH STRENGTH BOLT <br />FRAME <br />SCHD <br />SCHEDULE <br />TRANS. <br />TRANSVERSE <br />BOT. <br />BOTTOM <br />CONT. <br />CONTINUOUS <br />EXT. <br />EXTERIOR <br />(A325 UNO) <br />MFR <br />MANUFACTURER <br />SHT <br />SHEET <br />TYP. <br />TYPICAL <br />BF, B.F. <br />BRACED FRAME <br />CTSK <br />COUNTERSINK <br />FFE <br />FINISH FLOOR ELEV. <br />HT <br />HEIGHT <br />MTL <br />METAL <br />SHTG <br />SHEATHING <br />UNO <br />UNLESS OTHERWISE <br />BEL. <br />BELOW <br />d <br />PENNY (NAILS) <br />FAB. <br />FABRICATION <br />IF; I.F. <br />INSIDE FACE <br />(N) <br />NEW MEMBER <br />SIM. <br />51MILAR <br />NOTED <br />BLDG <br />BUILDING <br />DET. <br />DETAIL <br />FND <br />FOUNDATION <br />INT. <br />INTERIOR <br />N5, N.S. <br />NEAR 51DE <br />SKW <br />5KEW(ED) <br />VERT, <br />VERTICAL <br />BLKG <br />BLOCKING <br />DEL <br />DOUBLE <br />FIN. <br />FINISHED) <br />J5T <br />J015T <br />NT5 <br />NOT TO SCALE <br />SOG <br />SLAB ON GRADE <br />VFY <br />VERIFY <br />BN, B.N. <br />BOUNDARY NAIL <br />DF, D.F. <br />DOUGLAS FIR <br />FLG <br />FLANGE <br />JT <br />JOINT <br />OC, O.C. <br />ON CENTER <br />5PC <br />SPACING <br />W/ <br />WITH <br />BNDRY <br />BOUNDARY <br />0, DIA. <br />DIAMETER <br />FLR <br />FLOOR <br />K <br />KIPS (11000 POUNDS) <br />OF, O.F. <br />OUT5IDE FACE <br />50. <br />SQUARE <br />WH5 <br />WELDED HEADED <br />BM <br />BEAM <br />DIAL. <br />DIAGONAL <br />FN, F.N. <br />FACE NAIL <br />LAT. <br />LATERAL <br />OH <br />OVER HANG <br />55 <br />SELECT STRUCTURAL <br />STUD <br />B.O. <br />BOTTOM OF <br />DIAPH. <br />DIAPHRAGM <br />F0, F.O. <br />FACE OF <br />LDGR <br />LEDGER <br />OPN'G <br />OPENING <br />STD <br />STANDARD <br />HP <br />WORK POINT <br />BRDG <br />BRIDGE (ING) <br />do <br />DITTO (DO OVER) <br />FRM'G <br />FRAMING <br />LF <br />LINEAL FEET <br />ORNT <br />ORIENTATE(ION) <br />STGR <br />STAGGER <br />WS <br />WESTERN SERIES <br />BRG <br />BEARING <br />D <br />DEPTH <br />F5, F.S. <br />FAR SIDE <br />LLH <br />LONG LEG HORIZ. <br />PAR <br />PARALLEL <br />STIFF. <br />STIFFENER <br />WTS <br />WELDED THREADED <br />B/W <br />BETWEEN <br />DWG <br />DRAWING <br />FTG <br />FOOTING <br />LLV <br />LONG LEG VERTICAL <br />P/C <br />PRECAST CONCRETE <br />STIR. <br />STIRRUP <br />STUD <br />CAN <br />CAMBER(ED) <br />DIAL <br />DOWEL <br />GA <br />GAGE <br />LS <br />LAG SCREW <br />PERP. <br />PERPENDICULAR <br />STL <br />STEEL <br />WWF <br />WELDED WIRE FABRIC <br />CANT. <br />CANTILEVER(ED) <br />(E) <br />EXISTING MEMBER <br />GALV. <br />GALVANIZED <br />L5L <br />TIMBER STRAND <br />PL <br />PLATE <br />STRUC. <br />STRUCTURE(AL) <br />X-STG <br />EXTRA STRONG <br />CG <br />CENTER OF GRAVITY <br />EA. <br />EACH <br />GB, G.B, <br />GRADE BEAM <br />BEAM <br />PLYWD <br />PLYWOOD <br />SYN. <br />SYMETRICAL <br />XX-57G <br />DOUBLE EXTRA <br />CIP <br />CAST IN PLACE <br />EF, E.F. <br />EACH FACE <br />GLB <br />GLU-LAM. BEAM <br />LT AT <br />LIGHT WEIGHT <br />P5L <br />PARALLAM BEAM <br />T <br />TOP <br />STRONG <br />DESIGN ARCHITECT <br />SDH Architect <br />2242 NW RESERVE CAMP CT <br />BEND, OR 97703 <br />206,369.8881 <br />E D 0 ` 4H <br />le 'j I <br />ROIC of WASHINGTON <br />8905 Towne Center Drive, Suite 108 <br />San Diego, CA 92122 <br />CONSULTANT <br />13228 NE 20TH ST, SUITE 100 <br />BELLEVUE, WA g8005 <br />425 614-091 / INFO@AU-ENG.COM <br />JOB NO: 23136 <br />10/25/2023 <br />SOUTHPOINT PLAZA <br />SUITE 1 - REPAIR <br />10121 EVERGREEN WAY #1 <br />EVERETT, WA <br />ISSUED / REVISED DATE <br />PERMIT SET 06.26.23 <br />PR01 10.24.23 <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />PERMIT SET 06.26.23 <br />GENERAL NOTES & <br />ABBREVIATIONS <br />S=001 <br />