Laserfiche WebLink
Universal Swivel Attachment <br />Fig. AF700 <br />g®W FM <br />LIMB APPROVED <br />- <br />if <br />FIG. AF700 Dimensions and Weight <br />A B C D L X Y Weight <br />In/mm InJmm In/mm In/mm In/mm InJmm In/mm Wkgs <br />1.40 1.983 1.400 1.280 6.40 2.80 1.91 2.25 <br />35.56 50.37 35.56 32.51 162.6 71.1 48.5 1.02 <br />Notes: <br />ASC Engineered Solutions'" brand bracing components are designed to be compatible ONLY with other <br />ASC Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. <br />Updated UL listing information may be viewed at www.uLcom and updated FM approval information <br />may be viewed Atwww.approvahunde.com. <br />V,ASC- <br />kkpEngineered Solutions <br />Material Specifications <br />Size Range <br />Brace Member. See Table <br />Anchors. 'A"- Cd" (Ml2—Ml8) <br />Material <br />Ductile Iron with Carbon Steel Hardware <br />Finish <br />❑ Plain <br />❑ Electro-Galvanized perASTM B633 <br />Service <br />A seismic swivel attachment designe d to connect <br />a brace membertothe building structure orto a <br />seismic structuralattachment. The AF700 rigidly <br />braces piping systems subjectedto horizontal <br />and vertical seismic loads. <br />Approvals <br />cULus Listed (ANSVUL 2039) ), FM Approved (FM <br />1950-13), & FM Tested (FM 1950-16). FM Tested <br />(ANSI/FM 1950-16). Complies with NFPA13, ASCE <br />7, IBC, & MSS SP-127 bracing requirements. <br />Features <br />The set screw provides a visual indication that <br />proper Installation has been achieved <br />Elinumbes brace member eccentricity by <br />concentrically [codingT' and 1 Y4" brace pipes <br />Ordering <br />Specify figure number, fastener size, finish and <br />description. <br />Disclaimer <br />ASC Engineered Solutions does not provide anywarranties <br />and specifically disc aims any lobilitywhatsoeverwith <br />respect to ASC bracing products and components that are <br />used in combination with products, parts or systems not <br />manufactured or sold by ASC. In no event shallASC be liable <br />for any incidental, direct, consequento 1, special orindirect <br />damages or lost profits where non—ASC bracing components <br />have been, or Are used. <br />Se is Brace- Seismic Fire Protection Design Tool maybe <br />accessed at www.seisbrace.com <br />910' AFCON. <br />An ASC Engineered Solution <br />PROJECT INFORMATION <br />APPROVAL STAMP <br />Project: Broadway Everett Self Storage <br />❑ Approved <br />Address: 8407 Broadway, Everett, WA 98208 <br />❑ Approved as noted <br />Contractor: <br />❑ Not approved <br />Engineer: <br />Remarks: <br />Submittal Date: June 23, 2023 <br />Notes 1: <br />Notes 2: <br />SS-05.21 page 1 SS-sue-AF700-v0220220408 <br />