Laserfiche WebLink
Model K Lateral Sway Brace <br />Fig. AF035 <br />FIG. AF035 cULus Listing per ANSUUL 203a (ASD) <br />Standard <br />Speicalty <br />Horizontal Load Rating at Brace Angle <br />Service <br />Pipe Size <br />Service <br />Service <br />300440 <br />450 590 <br />600 900 <br />Listed <br />Pipe <br />Pipe <br />Ibt/kN <br />Ibt/kN <br />Ibt/kN <br />Ibt/kN <br />Sch.10 <br />Mega Thread <br />1" <br />Sch.40 <br />MLT/GL <br />(DN25) <br />CPVC <br />Eddy Thread <br />Metric Pipe <br />EZ-Thread <br />Mega Flow <br />Sch.10 <br />MLT/GL <br />174 <br />Sch.40 <br />Mega Thread <br />(DN32) <br />CPVC <br />Eddy Flow <br />Metric Pipe <br />Eddy Thread <br />EZ-Thread <br />Mega Flow <br />Sch. 10 <br />MLT/GL <br />11/" <br />Sch.40 <br />Mega Thread <br />(DN40) <br />CPVC <br />Eddy Flow <br />Metric Pipe <br />Eddy Thread <br />EZ-Thread <br />Fire Flo <br />625 <br />884 <br />1082 <br />1250 <br />2.78 <br />3.93 <br />4.81 <br />5.56 <br />Mega Flow <br />Sch. 10 <br />MLT/GL <br />2" <br />Sch.40 <br />Mega Thread <br />(DN50) <br />CPVC <br />Eddy Flow <br />Metric Pipe <br />Eddy Thread <br />EZ-Thread <br />Fire Flo <br />Sch.10 <br />Mega Flow <br />21/2 <br />Sch.40 <br />Eddy Flow <br />CPVC <br />Fire Flo <br />DN65 <br />3" <br />(DN80) <br />Metric Pipe <br />Sch.10 <br />Sch.40 <br />CPVC <br />Metric Pipe <br />- <br />Mega -Flow <br />Eddy Flow <br />Fire Flo <br />4. <br />Sch.10 <br />Mega Flow <br />(DN100) <br />Sch.40 <br />Eddy Flow <br />Metric Pipe <br />Fire Flo <br />5. <br />Sch.10 <br />(DN125) <br />Sch.40 <br />- <br />Metric Pipe <br />DN150 <br />Metric Pipe <br />- <br />942 <br />1333 <br />1632 <br />1885 <br />Sch.10 <br />4.19 <br />5.93 <br />7.26 <br />8.38 <br />6 <br />Sch.40 <br />Mega Flow <br />DN200 <br />Metric Pipe <br />- <br />8. <br />0.188" wall <br />Sch. 40 <br />10" <br />0.188" wall <br />Sch. 40 <br />12. <br />0.188" wall <br />_ <br />1125 <br />1591 <br />1948 <br />2250 <br />Sch.40 <br />5.00 <br />7.08 <br />8.67 <br />10.01 <br />1) Brace Angles are determined from Vertical <br />2) Sch.10 & 0188" Wall Load Ratings may be used for anythickerwall pipe of the same diameter <br />3) Listed Load ratings reduced for angle ranges in accordance with TETRA 13-2019 Table 18 5.23. <br />4) See table below for U L Listed specialty pipes & U L Listed metric sewice pipes. <br />5) Load Ratings reflect T'(DN25)-2"(DN50)brace members. See table below for Listed <br />brace members. <br />6) Minimum safetyfactor of 22 in accordance with TETRA 13-2019 Section A18523. <br />V,ASC- <br />kkpEngineered Solutions <br />Lateral Application <br />Lateral Application <br />Riser Application <br />®©c <br />asc-es.com <br />Building connections that Last- <br />SS-0421 page 3 SS-SUB-AF035-vo320220408 <br />