My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8407 BROADWAY SECURE SPACE STORAGE 2026-01-02
>
Address Records
>
BROADWAY
>
8407
>
SECURE SPACE STORAGE
>
8407 BROADWAY SECURE SPACE STORAGE 2026-01-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 10:56:06 AM
Creation date
6/17/2025 8:39:18 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8407
Tenant Name
SECURE SPACE STORAGE
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1489
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tgcu Fire & Building <br />Products <br />Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 <br />Model BFV-N Butterfly Valve <br />Wafer Style <br />21nch - 12 Inch (DN50 - DN300) <br />General <br />Description <br />The Model BFV-N Wafer Style Butter- <br />fly Valves (Ref. Figure 1) are indicat- <br />ing type valves designed for use in fire <br />protection systems where a visual in- <br />dication is required as to whether the <br />valve is open or closed. They are used, <br />for example, as system, sectional, and <br />pump water control valves. They are <br />suitable for installation between ANSI <br />Class 125 or 150 flanges without the <br />need for flange gaskets. <br />For applications requiring supervision <br />of the open position of the valve, the <br />Gear Operators for the Model BFV-N <br />Butterfly Valves are provided with <br />two sets of factory installed internal <br />switches each having SPDT contacts. <br />The supervisory switches transfer their <br />electrical contacts when there is move- <br />ment from the valve's normal open po- <br />sition during the first two revolutions of <br />the handwheel. <br />WARNINGS <br />The Model BFV-N Wafer Style Butter- <br />fly Valves described herein must be in- <br />stalled and maintained in compliance <br />with this document, as well as with the <br />applicable standards of the National <br />Fire Protection Association, in addition <br />to the standards of any other authori- <br />ties having jurisdiction. Failure to do <br />so may impair the performance of <br />these devices. <br />The owner is responsible for maintain- <br />ing their fire protection system and de- <br />vices in proper operating condition. <br />The installing contractor or sprinkler <br />manufacturer should be contacted <br />with any questions. <br />Technical <br />Data <br />Model <br />BFV-N <br />Sizes: ANSI Inches / DN <br />2 (DN50), 2-1/2 (DN65), 3 (DN80), <br />4 (DN100), 5 (DN125), 6 (DN150), <br />8 (DN200), 10 (DN250)1 12 (DN300) <br />Approvals <br />The 2 through 12 inch (DN50 - DN300) <br />Model BFV-N Wafer Style Butterfly <br />Valves are UL and C-UL Listed and FM <br />Approved. <br />In addition, the Model BFV-N Wafer <br />Style Butterfly Valves are listed by the <br />California State Fire Marshall under <br />Listing No. 7770-1670:101. <br />All laboratory listings and approvals are <br />for indoor and outdoor use. <br />Maximum Working Pressure <br />250 psi (17,2) bar <br />Materials of Construction: <br />Body <br />Ductile iron conforming to ASTM A-536 <br />Disc <br />Ductile iron conforming to ASTM A-395, <br />Nickel Plated <br />Seat Material <br />Grade EPDM "E" rubber conforming <br />to ASTM D-2000 <br />Upper Stem <br />Type 416 Stainless Steel conforming <br />to ASTM 582 <br />Operator <br />Gear operator with iron housing <br />Friction Loss <br />The approximate friction loss, based <br />on the Hazen Williams formula and ex- <br />pressed in equivalent length of pipe <br />with C= 120, is as follows. Unless oth- <br />erwise indicated, the data is based on <br />friction loss information collected at a <br />typical flow rate of 15 feet per second. <br />• 4.4 feet of 2 inch Sch. 40 pipe for <br />the 2 inch valve. <br />• 6.2 feet of 2-1/2 inch Sch. 40 pipe <br />forthe 2-1/2 inch valve. <br />• 7.6 feet of 3 inch Sch. 40 pipe for <br />the 3 inch valve. <br />• 9.2 feet of 4 inch Sch. 40 pipe for <br />the 4 inch valve. <br />• 9.0 feet' of 5 inch Sch. 40 pipe for <br />the 5 inch valve. <br />• 8.2 feet of 6 inch Sch. 40 pipe for <br />the 6 inch valve. <br />• 12.7 feet' of 8 inch Sch. 30 pipe for <br />the 8 inch valve. <br />• 20.1 feet' of 10 inch Sch. 30 pipe <br />forthe 10 inch valve. <br />• 22.3 feet' of 12 inch Sch. 30 pipe <br />forthe 12 inch valve. <br />'NFPA 13 <br />Page 1 of 4 MAY, 2007 TFPiSiS <br />
The URL can be used to link to this page
Your browser does not support the video tag.