Structural Brace Attachment <br />Fig. AF087 <br />AWL us FM <br />LISTED APPROVED <br />FIG. AF087 Dimensions and Weight <br />Mounting <br />A <br />B L W <br />H <br />Weight <br />Bolt <br />In./mm <br />In./mm In./mm In./mm <br />In./mm <br />Ibs/kg <br />'/2" <br />(M12) <br />0.75 <br />19.1 <br />0.50 4.25 2.00 <br />12.7 108.0 50.8 <br />2.13 <br />54.0 <br />2.00 <br />0.91 <br />Patent: No.6,629,678 <br />Notes: <br />ASC Engineered SolutionSTm brand bracing components are designed to be compatible ONLY with other ASC <br />Engineered Solutions brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL <br />Listing information may be viewed at www.uL.com and updated FM approval information may be viewed at <br />www.approvaLguide.com. <br />V,ASC- <br />kkp <br />Engineered Solutions <br />Material Specifications <br />Size Range: <br />Flange Thickness: Ys" —'/2" <br />Material <br />Ductile Iron Casting with Carbon Steel Hardware <br />Finish <br />❑ Plain <br />❑ Electro-Galvanized perASTM B633 <br />Service <br />A seismic structural attachment designed to <br />attach to steel I -beams, flanges, and joists. The <br />AF087 rigidly braces piping systems subjected to <br />horizontal and vertical seismic loads. The AfO87 <br />is also UL listed as an upper hanger attachment <br />for up to 6" pipe at maximum allowed hanger <br />spacing. <br />Approvals <br />cULus Listed (ANSI/UL 203a) and FM Approved <br />(FM 1950-13). Complies with NFPA13, ASCE 7, <br />IBC, & MSS SP-127 bracing requirements. UL 203 <br />Listed as a hanger attachment. <br />Features <br />The set screw provides a visual indication that <br />proper installation has been achieved. <br />Ordering <br />Specify figure number, finish, and description. <br />Disclaimer: <br />ASC Engineered Solutions does not provide any warranties <br />and specifically disclaims any liability whatsoever with <br />respect to ASC bracing products and components that are <br />used in combination with products, parts or systems not <br />manufactured orsold by ASC. In no event shallASC be <br />liable for any incidental, direct, consequential, special or <br />indirect damages or lost profits where non-ASC bracing <br />components have been, or are used. <br />Seis Brace' Seismic Fire Protection Design Tool may be <br />accessed at www.seisbrace.com <br />AFCON® <br />An ASC Engineered Solution <br />PROJECT INFORMATION <br />APPROVAL STAMP <br />Project: <br />❑ Approved <br />Address: <br />❑ Approved as noted <br />Contractor: <br />❑ Not approved <br />Engineer: <br />Remarks: <br />Submittal Date: <br />Notes 1: <br />Notes 2: <br />SS-01.22 page 1 SS-SUB-AF087-v02 20220113 <br />