Laserfiche WebLink
Downstream Link: None <br />LINK DATA ... ... ... .... ... ... <br />SCENARIO:POSTDEVELOPED <br />Number of Links: 2 <br />Link Name: Vault <br />Link Type: Structure <br />Downstream Link Name: POC <br />Prismatic Pond Option Used <br />Pond Floor Elevation (ft) <br />100.00 <br />Riser Crest Elevation (ft) <br />Max Pond Elevation (ft) <br />108.00 <br />Storage Depth (ft) <br />7.50 <br />Pond Bottom Length (ft) <br />47.5 <br />Pond Bottom Width (ft) <br />47.1 <br />Pond Side Slopes (ft/ft) <br />L1= 0.00 <br />Bottom Area (sq-ft) <br />2237. <br />Area at Riser Crest El (sq-ft) <br />2,237. <br />(acres) <br />0.051 <br />Volume at Riser Crest (cu-ft) <br />16,779. <br />(ac-ft) <br />0.385 <br />Area at Max Elevation (sq-ft) <br />2237. <br />(acres) <br />0.051 <br />Vol at Max Elevation (cu-ft) <br />17,898. <br />(ac-ft) <br />0.411 <br />107.50 <br />L2= 0.00 W1= 0.00 W2= 0.00 <br />Hydraulic Conductivity (in/hr) : 0.00 <br />Massmann Regression Used to Estimate Hydralic Gradient <br />Depth to Water Table (ft) 100.00 <br />Bio-Fouling Potential Low <br />Maintenance Average or Better <br />Riser Geometry <br />Riser Structure Type Circular <br />Riser Diameter (in) 18.00 <br />Common Length (ft) 0.000 <br />Riser Crest Elevation 107.50 ft <br />Hydraulic Structure Geometry <br />Number of Devices: <br />---Device Number <br />1 --- <br />Device Type <br />Circular Orifice <br />Control Elevation (ft) <br />100.00 <br />Diameter (in) <br />0.87 <br />Orientation <br />Horizontal <br />Elbow <br />No <br />---Device Number 2 --- <br />