Laserfiche WebLink
500-Year 0.670 <br />*******'Groundwater Recharge Summary **** *** ** <br />Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures <br />Total Predeveloped Recharge During Simulation <br />Model Element Recharge Amount (ac-ft) <br />Subbasin: WQ NORTH 108.513 <br />Link: POC 0.000 <br />Total: <br />108.513 <br />Total Post Developed Recharge During Simulation <br />Model Element Recharge Amount (ac-ft) <br />Subbasin: WQ NORTH 30.480 <br />Link: POC 0.000 <br />Total: <br />Total Predevelopment Recharge is Greater than Post Developed <br />Average Recharge Per Year, (Number of Years= 158) <br />Predeveloped: 0.687 ac-ft/year, Post Developed: 0.193 ac-ft/year <br />***********Water Quality Facility Data *** **** ** <br />=10f_1:7Iola Ja=1I]41Fl=1t0]»I] <br />Number of Links: 1 <br />********** Link: POC ********** <br />Infiltration/Filtration Statistics <br />Inflow Volume (ac-ft): 44.83 <br />Inflow Volume Including PPT-Evap (ac-ft): 44.83 <br />Total Runoff Infiltrated (ac-ft): 0.00, 0.00% <br />Total Runoff Filtered (ac-ft): 0.00, 0.00% <br />Primary Outflow To Downstream System (ac-ft): 44.83 <br />Secondary Outflow To Downstream System (ac-ft): 0.00 <br />Volume Lost to ET (ac-ft): 0.00 <br />Percent Treated (Infiltrated+Filtered+ET)/Total Volume: 0.00% <br />----------------------SCENARIO: POSTDEVELOPED <br />Number of Links: 1 <br />********** Link: POC ********** <br />Basic Wet Pond Volume (91% Exceedance): 2263. cu-ft <br />Computed Large Wet Pond Volume, 1.5*Basic Volume: 3395. cu-ft <br />