My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
200 W MARINE VIEW DR BAYWOOD 2025-09-16
>
Address Records
>
W MARINE VIEW DR
>
200
>
BAYWOOD
>
200 W MARINE VIEW DR BAYWOOD 2025-09-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2025 8:55:40 AM
Creation date
6/17/2025 12:18:29 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
200
Tenant Name
BAYWOOD
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2782
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHUTLER <br />CONSULTING <br />ENGINEERS, INC. 12503 Bel -Red Road, Suite 100, Bellevue, WA 98005* (425) 450-4075 * FAX (425) 450-4076 <br />February 23rd, 2021 <br />Todd Schutz <br />Nelson Architects (Formerly Craft) <br />1200 Fifth Avenue, Suite 1300 <br />Seattle, WA 98101 <br />RE: Structural Building Permit Review Letter No. B2011-018_Rl <br />Latitude Development, LLC — Baywood Industrial <br />200 W Marine View Drive <br />Everett, WA 98201 <br />Mr. Schutz, <br />Project #20-33 <br />In response to the permit review letter provided by the City of Everett please find the following summary of <br />updates and revisions to the structural drawings. <br />The following are general updates that have been made as part of our internal review process. These changes are <br />reflected on the latest set of structural drawings. <br />• Slab -on -grade joint details were added to Sheet 51.1 <br />• Perimeter isolated footings were sized and located appropriately on the foundation plan Sheet 52.0 <br />• Slab -on -grade as a structural diaphragm is now indicated on the foundation plan Sheet 52.0 <br />• Wall -ties have been added to the roof plan Sheet 52.1 <br />• Canopies and details were added to a new Sheet 54.0 <br />We have reviewed the structural comments prepared by the City of Everett. The comment followed by our <br />response are as indicated below: <br />Structural and geotechnical special inspections are required for this project. A statement on special <br />inspections is provided in the "Statement of Special Inspections" section of the General Notes on Sheet <br />S 1.0. The statement should include a table listing each type of special inspection and should specify the <br />extent of each inspection (e.g., continuous, periodic) per IBC Section 1704.3.1. The table should include <br />special requirements for seismic and wind resisting systems as required by IBC Sections 1704.3.2 and <br />1704.3.3, respectively. See IBC Sections 107.1, 1704.2.3 and 1704.3. <br />Response: A table listing special inspections, extent and special requirements for seismic and wind <br />resisting systems is provided on Sheet 51.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.