GENERAL NOTES <br />U <br />J <br />J <br />ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATIONS, THESE GENERAL NOTES <br />AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH <br />DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF <br />SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL <br />CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO <br />PROCEEDING WITH ANY WORK OR FABRICATION. THE STRUCTURE HAS BEEN DESIGNED TO RESIST <br />CODE SPECIFIED VERTICAL AND LATERAL FORCES AFTER THE CONSTRUCTION OF ALL STRUCTURAL <br />ELEMENTS HAS BEEN COMPLETED. STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS THE <br />SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS RESPONSIBILITY INCLUDES BUT IS NOT <br />LIMITED TO JOB SITE SAFETY; ERECTION MEANS, METHODS, AND SEQUENCES; TEMPORARY <br />SHORING, FORMWORK, BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. <br />CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE <br />WITH DESIGN ASPECTS ONLY AND IS NOT INTENDED IN ANY WAY TO REVIEW THE CONTRACTOR'S <br />CONSTRUCTION PROCEDURES. <br />STANDARDS <br />ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 <br />INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL <br />BUILDING OFFICIAL OR APPLICABLE JURISDICTION. <br />APPLICABLE STRUCTURAL PROVISIONS: <br />• 2018 INTERNATIONAL BUILDING CODE (IBC) <br />DESIGN CRITERIA <br />VERTICAL LOADS <br />AREA <br />DESIGN DEAD <br />LOAD <br />LIVE LOAD <br />ROOF <br />15 PSF <br />25 PSF (SNOW) <br />OTHER ROOMS FLOORS <br />15 PSF <br />40 PSF (2) <br />STAIRS <br />ACTUAL <br />100 PSF (OR 300# PER TREAD) <br />DECKS <br />ACTUAL <br />1 60 PSF <br />(1) LIVE LOAD REDUCTION NOT PERMITTED EXCEPT AS NOTED IN IBC SECTION 1607.10. <br />(2) 30 PSF FOR SLEEPING AREAS <br />SNOW: (MINIMUM ROOF SNOW LOAD = 25 PSF) <br />Pg = 25 PSF = GROUND SNOW LOAD <br />Pf = 0.7CeCt IsPg = FLAT ROOF SNOW LOAD <br />Ps = CsPf = SLOPED ROOF SNOW LOAD <br />Is = 1.0 Ce = 1.0, Ct = 1.0, Cs = VARIES <br />LATERAL FORCES <br />THE BUILDING MEETS THE CRITERIA TO USE THE "EQUIVALENT LATERAL FORCE PROCEDURE" PER <br />ASCE 7-16. <br />WIND: <br />ffm <br />- EXPOSURE CATEGORY = B <br />- BASIC WIND SPEED, (3 SEC. GUST), VULT = 110 MPH <br />-WIND IMPORTANCE FACTOR, Iw = 1.0 <br />- OCCUPANCY BUILDING CATEGORY PER TABLE 1-1 = II <br />- INTERNAL PRESSURE COEFFICIENT (ENCLOSED) _ ± 0.18 <br />- TOPOGRAPHIC FACTOR KZT = 1.00 <br />SEISMIC: <br />SEISMIC IMPORTANCE FACTOR) e = 1.0 <br />RISK CATEGORY OF BUILDING PER TABLE 1.5-1 = II <br />SPECTRAL RESPONSE ACCELERATIONS Ss = 1.351 & S1 = 0.479 <br />SITE CLASS PER TABLE 20.3-1 = D <br />DESIGN SPECTRAL RESPONSE ACCELERATIONS Sds = 1.081 <br />SEISMIC DESIGN CATEGORY = D <br />ANALYSIS PROCEDURE USED = SIMPLIFIED LATERAL FORCE ANALYSIS <br />RESPONSE MODIFICATION FACTOR PER TABLE 12.2-1, R = 6.5 <br />FOUNDATION DESIGN CRITERIA <br />SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* <br />ACTIVE PRESSURE - RESTRAINED: 55 PCF +14H SEISMIC SURCHARGE (ASSUMED) <br />ACTIVE PRESSURE - UNRESTRAINED: 35 PCF +6H SEISMIC SURCHARGE (ASSUMED) <br />PASSIVE RESISTANCE: 200 PCF (INCLUDES F.O.S. >_ 1.5) (ASSUMED) <br />COEFFICIENT OF FRICTION:.35 (INCLUDES F.O.S. >_ 1.5) (ASSUMED) <br />ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR "STRUCTURAL BACKFILL". NATIVE EARTH BEARING <br />SHALL BE SURFACE COMPACTED. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c= <br />2000 PSI) OR "STRUCTURAL BACKFILL". AREAS DESIGNATED "STRUCTURAL BACKFILL" SHALL BE FILLED WITH <br />APPROVED WELL -GRADED BANKRUN MATERIAL. MAXIMUM SIZE OF ROCK 4". FROZEN SOIL, ORGANIC MATERIAL <br />AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF ITS MAXIMUM DENSITY AS <br />DETERMINED BY ASTM D1557. PROVIDE DRAINAGE AND DEWATERING AROUND ALL WORK TO AVOID <br />WATER -SOFTENED FOOTINGS. <br />FREE DRAINING BACKFILL MATERIAL FOR RETAINING & BASEMENT WALLS <br />A CLEAN, FREE DRAINING, WELL GRADED GRANULAR MATERIAL CONFORMING TO ASTM D2487 GW OR SW <br />WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE <br />NO. 200 SIEVE) DOES NOT EXCEED 5%, <br />1 ■�11��11 11 � C_ • <br />CONCRETE <br />% PASSING U.S. NO. 200 SIEVE <br />% PASSING U.S. NO. 40 SIEVE <br />SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED FOR <br />APPROVAL A MINIMUM OF 2 WEEKS PRIOR TO BID, ALONG WITH CALCULATIONS THAT ARE PREPARED AND <br />SEALED BY A REGISTERED PROFESSIONAL ENGINEER (LICENSED IN THE STATE IN WHICH THE PROJECT <br />OCCURS) DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT <br />PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE <br />AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. <br />CONCRETE ANCHORS: <br />- ADHESIVE ANCHORS: HILTI HIT-HY 200 (ICC-ESR-3187) <br />*CONCRETE SHALL BE A MINIMUM OF 21 DAYS OLD AT TIME OF INSTALLATION. <br />*CONCRETE SHALL BE IN THE TEMPERATURE RANGE AS REQUIRED BY THE CONCRETE <br />MANUFACTURER. <br />*HOLE SHALL BY HAMMER -DRILLED ONLY. <br />*HOLE SHALL BE DRY AT TIME OF INSTALLATION. <br />*INSTALLER OF HORIZONTAL OR UPWARDLY INCLINED (ANY POSITION EXCEPT DIRECTLY <br />DOWNWARD) ANCHORS SHALL ALSO BE CERTIFIED BY THE ACl/CRSI ADHESIVE ANCHOR <br />INSTALLER CERTIFICATION PROGRAM. <br />- EXPANSION ANCHORS: KWIKBOLT TZ (ICC ESR-1917) BY HILTI, INC. OR STRONG -BOLT 2 (ICC ESR-3037) BY <br />SIMPSON STRONG TIE, INC. <br />- SCREW ANCHORS: KWIK HUS-EZ (ICC ESR-3027) BY HILTI, INC. OR TITEN HD (ICC ESR-2713) BY <br />SIMPSON STRONG TIE, INC. <br />STRUCTURALSTEEL <br />= 2/3 MAX. DETAILING, FABRICATION AND ERECTION <br />CONCRETE: MODERATE WEATHERING POTENTIAL SHALL BE MADE WITH PORTLAND CEMENT SHALL BE MADE <br />WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I, COARSE AND FINE AGGREGATE ASTM C-33, WATER <br />CLEAN AND POTABLE AND SHALL BE READY MIXED PER ASTM C-94. NO ALUMINUM (CONDUIT, MISCELLANEOUS <br />ITEMS, ETC.) SHALL BE EMBEDDED IN ANY CONCRETE. COORDINATE FORMWORK AND FINISH TYPES <br />ACCEPTABLE TO THE OWNER. <br />MAX <br />MIN. <br />AGGREGATE <br />ITEM <br />DESIGN f'c (PSI) <br />W/C <br />FLYASH <br />GRADING <br />NOTES <br />(AT 28 DAYS U.N.O.) <br />RATIO <br />OR SLAG <br />ASTM AASHTO <br />(PCYSLAB <br />ON GRADE <br />2500 <br />0.45 <br />100 <br />57 OR 67 <br />1 <br />FOUNDATIONS - LINO <br />2500 <br />0.50 <br />-- <br />57 OR 67 <br />STEM WALLS <br />2500 <br />0.45 <br />100 <br />57 OR 67 <br />CONCRETE MIX NOTES: <br />1. FIBROUS CONCRETE REINFORCEMENT SHALL BE "FIBERMESH" MANUFACTURED BY PROPEX CONCRETE <br />SYSTEMS OR PRE -APPROVED EQUAL. DOSAGE SHALL FOLLOW MANUFACTURER'S RECOMMENDATION BUT <br />NOT LESS THAN 1.5 LB/CU. YD. <br />2. PROVIDE 3000 PSI AT 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, <br />EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL <br />GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED CONFORMING TO ASTM C-260. TOTAL AIR <br />CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. <br />PLACE CONCRETE: PER ACI 304 AND CONFORM TO ACI 305 AND 306 FOR HOT AND COLD WEATHER PLACEMENT <br />AND CURING PROTECTION. USE INTERIOR MECHANICAL VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO <br />NOT OVER -VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION <br />JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD <br />TEMPERATURE FOR SEVEN DAYS AFTER POURING. <br />r,Rni IT <br />NON -SHRINK GROUT: GROUT SHALL CONFORM TO CRD-C621. F'c = 5000 PSI IN 28 DAYS. FILL OR PACK ENTIRE <br />SPACE UNDER PLATES OR SHAPES. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION, <br />INSTALLATION, AND CURING. <br />REINFORCING STEEL <br />REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. DETAIL, FABRICATE AND PLACE PER ACI 315 <br />AND ACI 378. LAP SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS <br />AT ALL HORIZONTAL BARS IN FOOTINGS AND WALLS. WELDED WIRE REINFORCEMENT SHALL CONFORM TO <br />A185. LAP ONE FULL MESH ON SIDES AND ENDS BUT NOT LESS THAN 8 INCHES. PLACE AT MID -DEPTH OF SLAB <br />OR AS SHOWN. <br />POST -INSTALLED ANCHORS <br />POST -INSTALLED ANCHORS: SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. <br />THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER PRIOR TO INSTALLING <br />POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. CARE SHALL BE <br />TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID CONFLICTS WITH REBAR. INSTALL IN ACCORDANCE <br />WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. INSTALLER SHALL BE QUALIFIED AND <br />TRAINED BY THE MANUFACTURER. HOLES SHALL BE HAMMER DRILLED ONLY (ROTARY DRILLED ONLY AT <br />UNREINFORCED MASONRY - NO HAMMER TOOLS). <br />ALL WORKMANSHIP SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION. <br />MATERIAL PROPERTIES <br />WIDE FLANGE SECTIONS: ASTM A992 (Fy = 50 KSI) <br />OTHER SHAPES AND PLATES: ASTM A36 (Fy = 36 KSI) TYP. U.N.O.; ASTM A572 (Fy = 50 KSI) WHERE INDICATED <br />HOLLOW STRUCTURAL SECTIONS: RECTANGULAR & SQUARE - ASTM A500 GRADE B (Fy = 46 KSI) ROUND - ASTM <br />A500 GRADE B (Fy = 42 KSI) <br />STRUCTURAL STEEL PIPES: ASTM A53, GRADE B, TYPE E OR S (Fy = 35 KSI) <br />MACHINE BOLTS (M.B.): ASTM A307, GRADE A <br />ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 55, UNLESS OTHERWISE NOTED, ASTM F1554, GRADE 105 WHERE <br />INDICATED. <br />WELDING <br />STRUCTURAL STEEL: WELD IN ACCORDANCE WITH "STRUCTURAL WELDING CODE" AWS D1.1. <br />CERTIFICATION: ALL WELDING SHALL BE PERFORMED BY WABO/AWS CERTIFIED WELDERS. WELDERS SHALL BE <br />PREQUALIFIED FOR EACH POSITION AND WELD TYPE WHICH THE WELDER WILL BE PERFORMING. <br />ELECTRODES: USE E70 ELECTRODES. <br />GENERAL REQUIREMENTS <br />ADHESIVE ANCHOR RODS: ASTM F1554, GRADE 36 UNLESS NOTED OTHERWISE. <br />FINISH: STRUCTURAL STEEL SHALL BE PRIMER PAINTED, UNLESS NOTED OTHERWISE. WHERE STRUCTURAL <br />STEEL IS NOTED TO BE GALVANIZED, IT SHALL BE HOT -DIP GALVANIZED IN ACCORDANCE WITH ASTM A123, A384, <br />AND A385. <br />STRUCTURAL DRAWING INDEX <br />SHEET NUMBER <br />SHEET DESCRIPTION <br />S0.0 <br />GENERAL NOTES <br />S0.1 <br />GENERAL NOTES <br />S1.0 <br />FOUNDATION FLOOR FRAMING PLAN <br />S2.0 <br />MAIN FLOOR FRAMING PLAN <br />S2.1 <br />ROOF FRAMING PLAN <br />S3.0 <br />SHEARWALL AND HOLDOWN LAYOUT <br />S4.0 <br />FOUNDATION DETAILS <br />S5.0 <br />FRAMING DETAILS <br />S6.0 <br />ISHEARWALL SCH. AND HOLDOWN DETAILS <br />Grand total: 9 <br />Of <br />~ <br />w <br />z <br />Y <br />O <br />�QJJ <br />N <br />Q <br />CID' <br />0 <br />U <br />0�COD <br />U <br />Lo <br />aa) c a <br />p <br />M <br />I.- <br />m EMcn <br />N O0 <br />i <br />���/ <br />vJ <br />�H <br />CO <br />Nw <br />LLJ <br />U <br />Z <br />LLJ <br />0 <br />L�J <br />.�L/ <br />f3f <br />co <br />O <br />J <br />U) <br />N <br />rn <br />J <br />> <br />LLJ <br />O <br />U rN 1 <br />w <br />0 <br />p <br />a) <br />Q <br />a LL_ <br />om <br />> <br />Ui <br />U) <br />LLJ <br />H <br />O <br />Z <br />J <br />Q <br />Lu <br />w Z <br />LLJ <br />O <br />w <br />w <br />a <br />N O <br />w <br />� Z <br />N <br />0 <br />ao O <br />M <br />N <br />SHEET <br />SO.O <br />