Laserfiche WebLink
UP 7R <br />FLOOR PLAN <br />41-011 <br />24'-b" <br />NIPII IIIAI I I IN= A;,nv� <br />© 2022 RECTOR RESIDENTIAL DESIGN, INC <br />- ALL DOOR/WINDOW HEADERS TO 13E 6 X5 DF� AT 2Xio SEARING WALLS , U.N.O., �'-0" MAX. SPAN <br />ALL DOOR/WINDOW HEADERS TO EtE 4X10 pP# AT 2X4 BEARING WALLS, U.N.O., 6'-O" MAX. SPAN <br />- WINDOW HE4DER5 4T 6 '-a" 4ECVE SUB FLOOR, U.N.O. <br />- PROVIDE FIREBLOCKING AS REQUIRED PER I.R.C. <br />- EXTERIOR WALLS TO BE 2X6 AT 16" (MIAX.) O.C. U.N.O. <br />- INTERIOR PARTITIONS TO BE 2 X 4 AT 16" O.G. (2X6 z PLUMBING WALLS, U.N.O.) <br />- DUCTS THROUGH WALL OR CEILING COMMON TO HOUSE MIN. 26 GAGE STEEL <br />- NO DUCT OPENINGS IN GARAGE <br />® PROVIDE SOLID FRAMING EQUAL TO THE WIDTH OF THE MEMBER BEING SUPPORTED (U.N.O.) <br />® FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS. LANDINGS OR FINISHED FLOORS AT THE <br />REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1 1/2" LOWER THAN THE TOP OF THRESHOLD. <br />PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR IRC R3113.1. EXCEPTION: <br />THE LANDING OR FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN T 4" BELOW THE TOP <br />OF THE THRESHOLD PROVIIDEE) THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR, IRC <br />R3113.2 <br />PLAN KEY <br />WALLS: <br />NEW CONSTRUCTION <br />EXISTING WALLS TO REMAIN <br />jlT1T1 EXISTING WALLS AND WINDOWS TO <br />5E REMOVED AND OR MODIFIED <br />3068 <br />NEW DOOR <br />EXISTING DOOR <br />EXISTING DOOR TO ISE <br />REMOVED AND OR MODIFIED <br />41-011 <br />PROPOSED <br />MAIN FLOO <br />AN, <br />SCALE : 1/4'= V-0' © 2022 RECTOR RESIDENTIAL DESIGN, INC <br />- PROVIDE FIREBLOCKING AS REQUIRED PER I.R.C, <br />- WINDOW HEADERS AT 6'-8" ABOVE SUB FLOOR, U.N.O. <br />- EXTERIOR W,4LL5 TO BE 2X6 AT 16" O.G., U.N.O. <br />- INTERIOR PARTITIONS TO BE 2X4 AT 1/o" O.C. (2Xi? '@ PLUMBING WALLS) U.N.O. <br />- PROVIDE 5UPPLEMENTAL JOISTS/BLOCKING BELOW SHEAR 1,4LL5 AS INDICATED ON FRX-ZING PLAN <br />PROVIDE SOLID FRAMING EQUAL TO THE WIDTH OF THE MEMBER BEING SUPPORTED (U.N.O.) <br />AREA SUMMARY <br />EXISTING <br />PROP05ED <br />TOTAL <br />MAIN FLOOR: <br />1400 SF. <br />269 SF. <br />669 SF. <br />LOWER FLOOR: <br />696 SF. <br />000 SF. <br />696 SF. <br />TOTAL: <br />2096 SF. <br />269 SF. <br />2365 5F. <br />GRAND TOTAL: <br />2365 SF. <br />CsARACs <br />576 SF. <br />O SF. <br />15MOKE DETECTOR5 <br />I INSTALL SMOKE DETECTORS PER CODE <br />110V INTERCONNECTED W/ BATTERY BACKUP <br />NSTALLED ON EACH FLOOR, IN EACH 5LE€PING AREA, <br />AND OUTSIDE EACH 5EPEIRATE 5LEE ING AREA <br />LISTED IN ACCORDANCE WITH UL 21-7 AND INSTALLED PER THE HOUSEHOLD <br />FIRE WARNING EQUIPMENT PROVISIONS OF NFPA T2 <br />GAR50N MONOXIDE <br />'t5D/CM IINSTALL 51"fOKE DECTOIR/ CARIBON MIONOXIDE 4L,4RRM PER CODE <br />COMBINATION 51`10KE ALARM $ CARBON MONOXIDE ALARMS: 51`10KE ALARM <br />REQUIREMENTS AS LISTED ABOVE. INSTALLED ON EACH FLOOR, AND OUTSIDE <br />EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS. CARBON MONOXIDE ALARMS LISTED 45 COMPLYING WITH UL 2075 <br />ANp INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS <br />VENTILATION <br />5GHEDULE <br />VENTILATION REQUIREMIENTS OF <br />IRC TABLE 1505.4.4 <br />SYMBOL <br />KITCHENS <br />100 CFM INTERMITTENT OR <br />30 CFM CONTINUOUS <br />24'-6" <br />I. ADDING II' ON TO KITCHEN ON THE MAIN FLOOR <br />PROPOSED <br />SCALE : 1/4'= V-0' <br />NOTE :POST ADDRESS NOTE: PROVIDE CONTINUOS <br />ON 5LDG. PRIOR TO PRE -PAINTED G.I. "T" PLASHING <br />FINAL INSPECTION AT ALL EXT. DOOR E WINDOW <br />HEADERS. <br />NOTE: <br />THE PROPOSED STRUCTURAL CONFIGURATION REPRESENTED HEREIN IS BASED <br />ON NON-INVASIVE SITE OBSERVATION OF THE EXISTING STRUCTURAL <br />CONDITIONS. AS A RESULT, IN CERTAIN INSTANCES, DESIGN ASSUMPTIONS WERE <br />USED TO FORMULATE THE COMPATIBILITY OP THE NEW CONSTRUCTION WITH THE <br />EXISTING STRUCTURAL ELEMENTS. DURING THE COURSE OF CONSTRUCTION, IT IS <br />POSSIBLE THAT CONDITIONS MAY 5E ENCOUNTERED THAT DO NOT COINCIDE <br />WITH THE DESIGN ASSUMPTIONS AND MAY REQUIRE FURTHER STRUCTURAL <br />REVIEW 5Y THE DESIGNER TO DETERMINE ADEQUACY. IT IS THE BUILDER'S <br />RESPONSIBILITY TO BE OBSERVANT OF THESE CONDITIONS AND IMMEDIATELY <br />R€PORT ANY DISCREPANCIES TO THE DESIGNER PRIOR TO PROCEEDING <br />FURTHER WITH THE WORK. <br />NOTE: <br />CONTRACTOR TO VERIFY ALL DIM€N51ON5 AND <br />CONDITIONS OF PROJECT AND REPORT ANY <br />OMISSIONS / DISCREPANCIES TO DESIGNER PRIOR <br />TO COMMENCING WORK. DESIGNER SHALL NOT 5E <br />RESPONSIBLE FOR DISCR€PANT CONDITIONS <br />RESULTING FROM UNAUTHORIZED WORK PERFORMED <br />NOTE: <br />fR€FEfR TO 5HEET S-1 FOfR SHEAfR WALL <br />SCHEDULE AND ENGINEEPRING FLAN UJNIGN <br />GONT4N pErtAL FEFEFENCEe ANEW/OF, <br />NSfiRUCTIONS Fi-RTAINING TO EACH 51=]=AR <br />WALL INDICATED IN THIS FLAN. <br />. - <br />M W� <br />W <br />Z6n-) <br />W <br />W <br />IV <br />FFCF05ED <br />MAIN FLOOF FLAN <br />U <br />z <br />Lu <br />C). <br />o <br />o� <br />n� <br />(P <br />nLLn� <br />1L/ <br />i�--- <br />LLI <br />These plans are copyrighted in <br />accordance with federal <br />statutes. Payment of use fee is <br />due Rector Residential Design, <br />LLC. prior to construction for <br />each structure built from these <br />plans. Reproduction by any <br />method of all, part or variations <br />thereof without written permission <br />from Rector Residential Design, <br />LLC. is expressly prohibited. <br />These drawings and all prints <br />therefrom remain the property of <br />Rector Residential Design, LLC. <br />REVISIONS <br />DESIGNER: O <br />DRAFTER: 0 <br />DATE: 2 /14/23 <br />PROJECP NO: 22150 <br />Ci :rtl � 1 <br />