Laserfiche WebLink
WoodWorks®Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> SHEARLINE,WALL and OPENING DIMENSIONS <br /> North-south Type Wall Location Extent[ft] Length FHS Aspect Height <br /> Shearlines Group X[ft] Start End [ft) [ft] Ratio [ft] <br /> Line 1 <br /> Level 2 <br /> Line 1 1 0.00 -11.50 0.00 11.50 9.00 - 7.75 <br /> Wall 1-1 NSW 0.00 -11.50 -9.00 2.50 0.00 1.00 - <br /> Wall 1-2 Seg 1 0.00 -9.00 0.00 9.00 9.00 0.86 - <br /> Level 1 <br /> Line 1 2 0.00 -11.50 0.00 11.50 4.00 - 8.00 <br /> Wall 1-1 Seg 2 0.00 -11.50 0.00 11.50 4.00 - - <br /> Segment 1 - - -11.50 -11.50 0.00 - - - <br /> Opening 1 - - -11.50 -4.00 7.50 - - 8.00 <br /> Segment 2 - - -4.00 0.00 4.00 - 2.00 - <br /> Line 2 <br /> Level 2 <br /> Line 2 1 24.50 -11.50 0.00 11.50 11.50 - 7.75 <br /> Wall 2-1 FT 1 24.50 -11.50 0.00 11.50 11.50 - - <br /> Segment 1 - - -11.50 -8.50 3.00 - 1.33 - <br /> Opening 1 - - -8.50 -2.50 6.00 - - 4.00 <br /> Segment 2 - - -2.50 0.00 2.50 - 1.60 - <br /> Level 1 <br /> Line 2 2 24.50 -11.50 0.00 11.50 4.00 - 8.00 <br /> Wall 2-1 Seg 2 24.50 -11.50 0.00 11.50 4.00 - - <br /> Segment 1 - - -11.50 -11.00 0.50 - 16.00 - <br /> Opening 1 - - -11.00 -4.30 7.00 - - 8.00 <br /> Segment 2 - - -4.00 0.00 4.30 - 2.00 - <br /> East-west Type Wall Location Extent[ft] Length FHS Aspect Height <br /> Shearlines Group Y[ft] Start End [ft] [ft] Ratio [ft] <br /> Line A <br /> Level 2 <br /> Line A 1 -11.50 0.00 24.50 24.50 14.50 - 7.75 , <br /> Wall A-1 NSW -11.50 0.00 8.50 8.50 0.00 1.00 - <br /> Wall A-2 Seg 1 -11.50 8.50 19.50 11.00 11.00 0.70 - <br /> Wall A-3 Seg 1 -11.50 19.50 23.00 3.50 3.50 2.21 - <br /> Wall A-4 NSW -11.50 23.00 24.50 1.50 0.00 '1.00 - <br /> Level 1 <br /> Line A 1 -11.30 0.00 24.50 24.50 21.50 - 8.00 <br /> Wall A-1 Seg 1 -11.50 3.00 24.50 24.50 21.30 - - <br /> Segment 1 - - 0.00 11.00 11.00 - 0.73 - <br /> Opening 1 - - 11.00 14.00 3.00 - - 4.00 <br /> Segment 2 - - 14.00 24.50 10.50 - 0.76 - <br /> Line B <br /> Level 2 <br /> Line B 1 0.00 0.00 24.50 24.50 8.50 - 7.75 <br /> Wall B-1 Seg 1 0.00 0.00 24.50 24.50 8.50 - - <br /> Segment 1 - - 0.00 2.00 2.00 - 3.88 - <br /> Opening 1 - - 2.00 4.00 2.00 - - 4.00 <br /> Segment 2 - - 4.00 8.50 4.50 - 1.72 - <br /> Opening 2 - - 8.50 20.50 12.00 - - 6.67 <br /> Segment 3 - - 20.50 24.50 4.00 - 1.94 - <br /> Level 1 <br /> Line B 1 0.00 0.00 24.50 24.50 8.00 - 8.00 <br /> Wall B-1 Seg _ 1 0.00 0.00 24.50 24.50 8.00 - - <br /> Segment 1 - - 0.00 4.00 4.00 - 2.00 - <br /> Opening 1 - - 4.00 20.50 16.50 - - 8.00 <br /> Segment 2 - - 20.50 24.50 4.00 - 2.00 - <br /> Legend: <br /> Type-Seg=segmented,Prf=perforated,FT=force-transfer,NSW=non-shearwall <br /> Location-Dimension perpendicular to wall <br /> FHS-Length of full-height sheathing used to resist shear force.For perforated walls,it is based on the factored segments Li defined in SDPWS 4.3.4.3 <br /> Aspect Ratio-Ratio of wall height to segment length(h/bs),for force-transfer walls,the aspect ratio of the central pier <br /> Wall Group-Wall design group defined in Sheathing and Framing Materials tables,where it shows associated Standard Wall <br /> 4 <br /> Page 29 of 63 <br />