Laserfiche WebLink
WoodWorks® Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> BUILDING MASSES <br /> Level2 Magnitude Trib <br /> Force Building Block Wall Profile Location[ft] [Ibs,plf,psf] Width <br /> Dir Element Line Start End Start End [ft] <br /> E-W Roof Block 1 1 Line -12.50 1.00 198.8 198.8 <br /> E-W Roof Block 1 2 Line -12.50 1.00 198.8 198.8 <br /> N-S Roof Block 1 A Line -1.00 25.50 101.3 101.3 <br /> N-S Roof Block 1 B Line -1.00 25.50 101.3 101.3 <br /> N-S L Gable Block 1 A Line 0.00 12.25 40.8 0.0 <br /> N-S R Sable Block 1 A Line 12.25 24.50 0.0 40.8 <br /> N-S R Gable Block 1 B Line 0.00 12.25 40.8 0.0 <br /> N-S L Gable Block 1 B Line 12.25 24.50 0.0 40.8 <br /> Both Wall 1-1 n/a 1 Line -11.50 -9.00 38.8 38.8 <br /> Both Wall 1-2 n/a 1 Line -9.00 0.00 38.8 38.8 <br /> Both Wall 2-1 n/a 2 Line -11.50 0.00 38.8 38.8 <br /> Both Wall A-1 n/a A Line 0.00 8.50 38.8 38.8 <br /> Both Wall A-2 n/a A Line 8.50 19.50 38.8 38.8 <br /> Both Wall A-3 n/a A Line 19.50 23.00 38.8 38.8 <br /> Both Wall A-4 n/a A Line 23.00 24.50 38.8 38.8 <br /> Both Wall B-1 n/a B Line 0.00 24.50 38.8 38.8 <br /> Level 1 Magnitude Trib <br /> Force Building Block Wall Profile Location[ft] [Ibs,plf,psf] Width <br /> Dir Element Line Start End Start End (ft] <br /> Both Wall 1-1 n/a 1 Line -11.50 -9.00 38.8 38.8 <br /> E-W Floor Fl n/a 1 Line -11.50 0.00 122.5 122.5 <br /> Both Wall 1-2 n/a 1 Line -9.00 0.00 38.8 38.8 <br /> Both Wall 2-1 n/a 2 Line -11.50 0.00 38.8 38.8 <br /> E-W Floor Fl n/a 2 Line -11.50 0.00 122.5 122.5 <br /> Both Wall A-1 n/a A Line 0.00 8.50 38.8 38.8 <br /> N-S Floor Fl n/a A Line 0.00 24.50 57.5 57.5 <br /> Both Wall A-2 n/a A Line 8.50 19.50 38.8 38.8 <br /> Both Wall A-3 n/a A Line 19.50 23.00 38.8 38.8 <br /> Both Wall A-4 n/a A Line 23.00 24.50 38.8 38.8 <br /> N-S Floor Fl n/a B Line 0.00 24.50 57.5 57.5 <br /> Both Wall B-1 n/a B Line 0.00 24.50 38.8 38.8 <br /> Both Wall 1-i n/a 1 Line -11.50 0.00 40.0 40.0 <br /> Both Wall 2-1 n/a 2 Line -11.50 0.00 40.0 40.0 <br /> Both Wall A-1 n/a A Line 0.00 24.50 40.0 40.0 <br /> Both Wall B-1 n/a B Line 0.00 24.50 40.0 40.0 <br /> Legend: <br /> Force Dir-Direction in which the mass is used for seismic load generation,E-W,N-S,or Both <br /> Building element-Roof,gable end,wall or floor area used to generate mass,wall line for user-applied masses,Floor F#-refer to Plan View for floor area <br /> number <br /> Wall line-Shearline that equivalent line load is assigned to <br /> Location-Start and end points of equivalent line load on wall line <br /> Trib Width.-Tributary width;for user applied area loads only <br /> 8 . <br /> Page 33 of 63 <br />