My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5010 DOVER ST 2025-07-31
>
Address Records
>
DOVER ST
>
5010
>
5010 DOVER ST 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 11:34:53 AM
Creation date
6/18/2025 7:40:08 AM
Metadata
Fields
Template:
Address Document
Street Name
DOVER ST
Street Number
5010
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
199
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WoodWorks® Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> MWFRS DEFLECTION(flexible wind design) <br /> These deflections are used to determine shearwall stiffness for force distribution <br /> Wall, W Bending Ga Nail slip Shear Hold Total <br /> segment Gp Dir Srf v b h A Defl kips/ Vn en Defl Defl Defl <br /> plf ft ft sq.in in in lbs in in in in <br /> Level 1 <br /> Line 1 <br /> 1-1,2 2 S->N Ext 709.2 4.00 8.00 16.5 .028 24.3 193 .030 .233 0.44 0.70 <br /> N->S Ext 709.2 4.00 8.00 16.5 .028 24.3 193 .030 .233 0.43 0.69 <br /> Line 2 <br /> 2-1,2 2 S->N Ext 709.2 4.00 8.00 16.5 .028 24.3 193 .030 .233 0.41 0.67 <br /> N->S Ext 709.2 4.00 8.30 16.5 .028 24.3 193 .030 .233 0.42 0.68 <br /> Line A <br /> 3-1,1 1 W->E Ext 52.3 11.00 8.00 16.5 .001 13.8 196 .032 .030 0.08 0.11 <br /> E->W Ext 54.1 11.00 8.00 16.5 .001 13.8 196 .032 .031 0.08 0.11 <br /> A-1,2 W->E Ext 51.3 10.50 8.00 16.5 .001 13.8 196 .032 .030 0.08 0.11 <br /> E->W Ext 49.5 10.50 8.00 16.5 .001 13.8 196 .032 .029 0.08 0.11 <br /> Line B <br /> B-1,1 1 W->E Ext 180.2 4.00 8.00 16.5 .007 13.8 196 .032 .104 0.30 0.41 <br /> E->W Ext 120.4 4.00 8.00 16.5 .005 13.8 196 .032 .070 0.34 0.41 <br /> B-1,2 W->E Ext 98.4 4.00 8.00 16.5 .004 13.8 196 .032 .057 0.35, 0.41 <br /> E->W Ext 158.3 4.00 8.00 16.5 .006 13.8 196 .032 .092 0.31i 0.41 <br /> Wall, W Bending Ga Nail slip Shear Hold Total <br /> segment Gp Dir Srf v b h A Defl kips/ Vn en Dell Defl Dell <br /> plf ft ft sq.in in in lbs in in in in <br /> Level 2 <br /> Line 1 <br /> 1-2 1 S->N Ext 142.1 9.00 7.75 16.5 .002 13.8 196 .032 .080 0.28 0.36 <br /> N->S Ext 142.1 9.00 7.75 16.5 .002 13.8 196 .032 .080 0.26 0.35 <br /> Line 2 <br /> 2-1 1 W->E - - 11.50 7.75 - - - - - - - 0.97 <br /> E->W - - 11.50 7.75 - - - - - - - 0.89 <br /> 2-1,1 S->N Ext 232.5 3.00 6.41 16.5 .007 13.8 196 .032 .108 0.79 0.91 <br /> N->S Ext 232.5 3.00 6.41 16.5 .007 13.8 196 .032 .108 0.69 0.80 <br /> 2-1,2 S->N Ext 232.5 2.50 6.41 16.5 .008 13.8 196 .032 .108 0.91 1.03 <br /> N->S Ext 232.5 2.50 6.41 16.5 .008 13.8 196 .032 .108 0.85 0.97 <br /> Line A <br /> 3-2 1 Both Ext 46.1 11.00 7.75 16.5 .001 13.8 196 .032 .026 0.23 0.25 <br /> 3-3 1 Both Ext 0.0 3.50 7.75 16.5 .000 13.6 196 .032 .000 0.00 0.00 <br /> Line B <br /> B-1,2 1 Both Ext 75.3 4.50 7.75 16.5 .002 13.8 196 .032 .042 0.58 0.63 <br /> B-1,3 Both Ext 42.0 4.00 7.75 16.5 .001 13.8 196 .032 .024 0.60 0.63 <br /> Legend: <br /> Wall,segment-Wall and segment between openings,e.g. 8-3,2=second segment on Wall 3 on Shearline 8 <br /> W Gp-Wall design group defined in Sheathing and Materials tables,where it shows associated Standard Wall. <br /> Dir-Force direction <br /> Srf-Wall surface,interior or exterior for perimeter walls, 1 or 2 for interior partitions <br /> v-ASD shear force per unit distance on wall segment.For perforated walls,vmax from SDPWS 4.3-9 is used,as per 4.3.2.1.For force-transfer walls,unit <br /> shear force in pier beside opening(s)is used. <br /> b-Segmented wall or force-transfer wall segments:Width of wall segment between openings.Perforated wall:Sum of FHS segments,modified as per <br /> SDPWS 4.3.2.1.Force-transfer wall:Length of wall including openings. <br /> h-Wall height.For force-transfer piers,distance from bottom of opening to top of wall is shown;for end segments,results using that distance and the wall <br /> height are averaged,as per APA T555. <br /> Defl-Horizontal shearwall deflection due to given term: <br /> Bending=8vh^3/EAb Cub;A-Cross sectional area of segment end stud(s);E-stud mod.of elasticity in Framing Materials table <br /> Shear=vh/1000 Ga Cub. Ga-vw/(vw/Gt+0.75 en),from SDPWS Ex.C4.3.2-1;vw-ASD sheathing capacity;Gt-Shear stiffness from C4.3.3.2, <br /> value is in Sheathing Materials table;en-Nail slip from table C4.2.2D;Vn-Shear force per nail along panel edge using vw <br /> Hold- Hold-down= da x h/b;refer to Hold-down Displacement table for components of da.For force-transfer walls,hold-down device at end of wall is <br /> applied to all segments,as per APA 7555. <br /> Cub-Unblocked factor from 4.3.2.2,shown in the Shear Results table. <br /> Total dell= Deflection from bending+shear+hold-down,as per SDPWS C4.3.2-1.For force-transfer walls,the average of the values for the segments,as <br /> per APA T555. <br /> 15 <br /> Page 40 of 63 <br />
The URL can be used to link to this page
Your browser does not support the video tag.