WoodWorks® Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> HOLD-DOWN DESIGN(rigid wind design) <br /> Level 1 Tensile ASD <br /> Line- Location[ft] Load Holddown Force[Ibs] Cap Crit <br /> Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [Ibs] Resp. <br /> Line 1 <br /> ✓ Elem 0.00 -11.62 1 771 541 230 Refer to upper level <br /> 1-1 R Op 1 0.00 -3.87 1 6443 215 6228 Refer to upper level <br /> 1-1 R End 0.00 -0.12 1 7220 486 6734 Refer to upper level <br /> Line 2 <br /> ✓ Elem 24.50 -11.37 1 840 621 219 Refer to upper level <br /> 2-1 R Op 1 24.50 -3.87 1 6076 6076 HDUB-SDS2. 6765 0.90 <br /> 2-1 R End 24.50 -0.12 1 6908 621 6287 Refer to upper level <br /> Line A <br /> A-1 L End 0.12 -11.50 1 661 330 331 HDU2-SDS2. 3075 0.11 <br /> ✓ Elem 8.62 -11.50 1 839 839 Refer to upper level <br /> A-1 L Op 1 10.88 -11.50 1 679 420 259 HDU2-SDS2. 3075 0.08 <br /> A-1 R Op 1 14.13 -11.50 1 650 405 245 HDU2-SDS2. 3075 0.08 <br /> ✓ Elem 19.38 -11.50 1 841 841 Refer to upper level <br /> A-1 R End 24.38 -11.50 1 632 315 317 HDU2-SDS2. 3075 0.10 <br /> Line B <br /> B-1 L End 0.12 0.00 1 671 120 551 HDU2-SDS2. 3075 0.18 <br /> B-1 L Op 1 3.88 0.00 1 321 615 <br /> B-1 R Op 1 20.63 0.00 1 388 615 <br /> B-1 R End 24.38 0.00 1 732 120 612 HDU2-SDS2. 3075 0.20 <br /> Level 2 Tensile ASD <br /> Line- Location[ft] Load Holddown Force[Ibs] Cap Crit <br /> Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [Ibs] Resp. <br /> Line 1 <br /> 1-1 L End 0.00 -11.37 135 <br /> 1-1 R End 0.00 -9.12 135 <br /> 1-2 L End 0.00 -8.87 1 1186 486 700 HDU2-SDS2. 3075 0.23 <br /> 1-2 R End 0.00 -0.12 1 1180 486 694 HDU2-SDS2. 3075 0.23 <br /> Line 2 <br /> 2-1 L End 24.50 -11.37 1 840 621 219 HDU2-SDS2. 3075 0.07 <br /> 2-1 R End 24.50 -0.12 1 844 621 223 HDU2-SDS2. 3075 0.07 <br /> Line A <br /> A-2 L End 8.62 -11.50 1 839 339 HDU2-SDS2. 3075 0.27 <br /> A-2 R End 19.38 -11.50 1 841 341 HD`J2-SDS2. 3075 3.27 <br /> Line B <br /> B-1 R Op 1 4.13 0.00 1 530 530 HDU2-SDS2. 3075 0.17 <br /> B-i L Op 2 8.38 0.00 1 530 530 HDU2-SDS2. 3075 0.17 <br /> B-1 R Op 2 20.63 0.00 1 112 112 HDU2-SDS2. 3075 0.04 <br /> B-1 R End 24.38 0.00 1 107 107 HDU2-SDS2. 3075 0.03 <br /> Legend: <br /> Line-Wall: <br /> At wall or opening-Shearline and wall number At vertical element-Shearline <br /> Posit'n-Position of stud that hold-down is attached to: <br /> V Elem-Vertical element:column or strengthened studs required where not at wall end or opening <br /> L or R End-At left or right wall end <br /> L or R Op n- At left or right side of opening n <br /> t @ Op n- Uplift force tat opening n from offset opening in perforated wall above,from SDPWS 4.3.6.2.1 <br /> Location-Co-ordinates in Plan View <br /> Load Case-Results are for critical load case: <br /> ASCE 7 All Heights:Case 1 or 2 from Fig.27.3-8 <br /> ASCE 7 Low-rise:Windward corner(s)and Case A or B from Fig.28.3-1 <br /> ASCE 7 Minimum loads(27.1.5/28.3.4) <br /> Hold-down Forces: <br /> Shear-Wind shear overturning component,based on shearline force,factored for ASD by 0.60.For perforated walls, T from SDPWS 4.3-8 is used. <br /> Dead-Dead load resisting component,factored for ASD by 0.60 <br /> Uplift-Uplift wind load component,factored for ASD by 0.60.For perforated walls, T from SDPWS 4.3-8 is used. <br /> Cmb'd-Sum of ASD-factored overturning,dead and uplift forces.May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when <br /> openings are staggered. <br /> Hold-down-Device used from hold-down database <br /> Cap-Allowable ASD tension load <br /> Crit.Resp.-Critical Response=Combined ASD force/Allowable ASD tension load <br /> Notes: <br /> Refer to Shear Results table for factor Co,and shearline dimensions table for the sum of Li,used to calculate tension force T for perforated walls from <br /> SDPWS Eqn.4.3-8. <br /> Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table.Refer to SDPWS 4.3.6.4.3 for <br /> foundation anchor bolt requirements. <br /> 19 <br /> Page 44 of 63 <br />