Laserfiche WebLink
ANALYSIS OF VALMONT INDUSTRIES LIGHTING STRUCTURE <br />IN ACCORDANCE WITH AASHTO-2015 RQMTS. (FINAL DEFLECTED POSITION) <br />BY: IW70 12/01/2021 VERSION: 24.5.25.1 <br />SUBJECT: Everett, WA - T50E300 DS210 - (2) 12' DS60(115MPH - AASHTO 2015) <br />Folder: 485175 File: P30L12A15AB <br />Description of EPA Loading <br />Description of <br />Load <br />Position of Load <br />Mounting <br />Height "Height <br />(ft) <br />Centroid <br />** <br />(ft) <br />Distance To <br />Centroid <br />From Pole <br />(ft) <br />Reight <br />(lb) <br />Effective <br />Projected <br />Area <br />(ft2) <br />Galtronics Omni <br />Pole <br />30.0000 <br />33.5000 <br />0.0000 <br />31 <br />1.24 <br />ommScope Metrocell enclosure <br />Pole <br />30.0000 <br />31.5000 <br />2.0000 <br />80 <br />3.00 <br />Future 5G units <br />Pole <br />24.3333 <br />24.3333 <br />2.0000 <br />90 <br />3.60 <br />CommScope Micro enclosure <br />Pole <br />17.5000 <br />17.5000 <br />2.0000 <br />300 <br />7.70 <br />Disconnect <br />Pole <br />17.5000 <br />17.5000 <br />0.2500 <br />8 <br />0.82 <br />Description of Luminare <br />Location <br />Shape <br />Mounting <br />Centroid <br />Distance <br />Weight <br />Projected <br />Height <br />Height <br />To <br />(lb) <br />rea(ft2) <br />** <br />** <br />Cent roid <br />(ft) <br />(ft) <br />From Pole <br />(ft) <br />LUM ARM1 <br />Rounded127.3333 <br />130.00001 <br />14.0000 <br />60 <br />2.00 <br />THE VALUES SHOWN IN THIS TABLE MUST NOT BE EXCEEDED <br />WITHOUT CONSULTING VALMONT. <br />ANY SIZES OR OTHER DIMENSIONS NOT PROVIDED BY THE <br />SPECIFYING AGENCY HAVE <br />BEEN ESTIMATED BY VALMONT. <br />" THESE HEIGHTS ARE ABOVE BOTTOM OF BASE PLATE OR <br />TRANSFORMER BASE. <br />4 <br />