Laserfiche WebLink
SEC. 29, T. 29 N, R. 5 E, W.M. — -- <br /> SEC. 32, T. 29 N, R. 5 E, W.M. a p D p — <br /> as 1 o SS a ao <br /> ea a a o <br /> SSMH #F <br /> CENTER OF STRUCTURE <br /> 5\ N: 355481.1387 5' LF 8" HDPE M o <br /> S E: 1307365.3503 <br /> a� <br /> S SSMH RG P <br /> � CENTER OF STRUCTURE SSMH #H D 0 I I <br /> N \S N: 355582.4244 CENTER OF STRUCTURE p <br /> E: 1307375.0600 N: 355650.1683 4 <br /> \S\ E: 1307368.4458 - <br /> Z S <br /> 3 \S KEY MAP <br /> o s NTS <br /> w s s SANITARY SEWER GENERAL NOTES: <br /> LIJ <br /> S S S S S 9 S BUILDING B 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT <br /> SEWER CONNECTION STUB STANDARDS AND WSDOT/APWA STANDARD SPECIFICATIONS, UNLESS <br /> 5' LF 8" HDPE IE=34.82 OTHERWISE APPROVED BY THE ENGINEER. <br /> 2. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, <br /> + CONCEALED OR PUT INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, <br /> L0 AND APPROVED BY THE CITY INSPECTOR. <br /> 3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED <br /> (n BUILDING B FROM AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE <br /> SEWER CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS <br /> W CONNECTION STUB AND TO AVOID DAMAGE TO ANY ADDITIONAL UTILITIES NOT SHOWN. IF <br /> Z IE=33.73 CONFLICTS WITH EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE <br /> J CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY <br /> CHANGES REQUIRED SHALL BE APPROVED BY THE OWNER'S <br /> REPRESENTATIVE AND THE CITY ENGINEER PRIOR TO COMMENCEMENT OF <br /> U RELATED CONSTRUCTION ON THE PROJECT. <br /> Q T SANITARY SEWER MANHOLES SHALL BE TYPE 1 MANHOLE PER CITY OF <br /> EVERETT STD. DWG. NO. 605 OR APPROVED EQUAL. <br /> 5. SANITARY SEWER PIPE SHALL BE HDPE PER WSDOT 2020 STANDARD <br /> SPECIFICATIONS SECTION 9-05.23 UNLESS OTHERWISE APPROVED. <br /> 6. GROUND ELEVATIONS FOR MANHOLES ARE BASED ON EXISTING GRADES. <br /> k FINAL STRUCTURE RIM ELEVATIONS ARE TO BE DETERMINED. MANHOLES <br /> INSTALLED IN THIS PHASE OF THE SITE DEVELOPMENT SHALL HAVE THE <br /> w X�X ABILITY TO HAVE THE FINAL RIM ELEVATION ADJUSTED BY t2'. <br /> 7. ALL SEWER MAINS SHALL BE INSTALLED WITH GREEN STRIPE ON PIPE <br /> X�k AND TRACING WIRE SHALL BE INSTALLED ABOVE THE PIPE BEDDING. <br /> z �x`X SEWER MAIN PIPE MATERIALS SHALL BE APPROVED BY THE CITY <br /> ENGINEER PRIOR TO CONSTRUCTION. <br /> X <br /> � 8. SANITARY SEWER MANHOLE LIDS SHALL BE INSTALLED PER C.O.E. STD. <br /> DWG. NO. 610. <br /> 9. FOR ADDITIONAL UTILITIES NOTES, SEE SHEET NT1. <br /> 3 <br /> E ISTING GRAD <br /> N F OM MASS GJADING <br /> 0 <br /> 0 <br /> 0 APPR XIMATE REFSE GRADE 40 <br /> o ----- __ - --------------- -------- <br /> I - <br /> --- ---- ----- - -- - <br /> 0 <br /> N Z <br /> n <br /> 3 c� <br /> ---- ---- ---- ---------- ---- --- -- — <br /> ---- 98 LF 19" HDPE ® 1.0% <br /> NI ----- 102 LF 12" HDPE ® 1.0% <br /> a Ld 237 LF 12" HDPE @ 1.0% <br /> W B ILDING B S WER <br /> j (n CONNECTION <br /> E LMH #H PE 1 MH 4E 30 <br /> i C) CONNECTION = <br /> SSMH #G PE 1 MH 8" E=34.43, 12" (S) <br /> + GE=39.31 <br /> 7 L0 SSMH F TYPE 1 MH 4 " IE=33.45, 12" (N) <br /> 2 Q GE=39.00 IE=33.35, 12" (S) 25 <br /> H <br /> N IE=32.23, 1 (S) <br /> i <br /> W <br /> 3 Z <br /> 20 J 20 <br /> � U <br /> � Q <br /> U <br /> 15 15 <br /> 10 10 <br /> E 6+00 7+00 8+00 9+00 10+00 <br /> SCALE <br /> W FEET�0 0 20 40 <br /> iN <br /> 0 1 10/22/19 ADDENDUM #1 - SEWER LINE ADDITION AND SITE LAYOUT REVISION G�oF WASNdtiC D—ing N. <br /> J�;_ Dro— By Date SHELTER HOLDINGS, LLC 1 <br /> �) PERTEET m P. HOUGHTALING B 15 19 SS2 <br /> Dsei9ned By EVERETT RIVERFRONT DEVELOPMENT <br /> V.WEN 8 15 19 Sheet No. <br /> 2707COLBYAVENUE,SUITE900 s4968 `� Checked B <br /> 0 0�RF �,o � y ADVANCED SITE WORK PERMIT <br /> o EVERETT,WA 98201 Know what's below. FSS/GISTEEtaG�� Approved By Project Ncmee� 23 28 <br /> No. Date Revision By Appr. <br /> 425.252.7700 800.615.9900 Call before you dig °" C. DGNNER e ,5 ,9 20180004.005 SANITARY SEWER PLAN & PROFILE of Tntnl <br />