Laserfiche WebLink
d <br /> I I <br /> m <br /> `7 <br /> W <br /> o' `� � <br /> COPE ALL FLANGES�� i i � i C � <br /> w <br /> 1/2^ BUILDING APRON PLY4"X 4"X 1'-4° W <br /> BEAM PER PLANS W/(2)%°DIAMETER THREADED q <br /> 5^ ROD HANGERS TO BEAM BELOW W F <br /> III-III -I I-III-III III-I <br /> /2 7 <br /> =1 III=III-III-I -III III-III 1- " N <br /> III-III-1 1 d 11, ---- 3" Y ° <br /> - <br /> r <br /> BEAM PER PLAN <br /> APPLY PRIMER TOIJIE <br /> ALL STEEL ELEMENTS C5X9 x 1'-4' <br /> ; 7 <br /> SCALE:1 1/2'=1'-0' SCALE:3/4'=1'-0' SHIM AS REO'D. HAR ENED WASHERSBOLTS W/ <br /> 03 TYPICAL DETAIL AT M.H. SUPPORT FRAME ® SIDE SEWER SUPPORT BEAM BUILDING APRON w M z <br /> d�J�by yeti <br /> 5'-0" pR <br /> MH <br /> REF-SEE CIVIL <br /> L 6x4x5/16 LLV 12"S.S.LINE L 6z4x5/16 LLV (4)3/4"M.B.x4' 4'DIA.HOLE xn rn $ <br /> EACH SIDE EACH SIDE SEE 9/SPI.3 V-8° FOR GROUTING <br /> d N <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �� 7" 6. 7" p o\ o 0 <br /> M W <br /> J ie <br /> ------------------- ——————————— 3"MIN. <br /> G <br /> / m rn <br /> CANTILEVER 3• <br /> o a F <br /> PL 1/a'x2'X 1'-2"DAM <br /> TYP EA END OF L6X4 SEWER SUPPORT BEAM <br /> w <br /> PER PLAN (2)1"DIAMETER M.B. M m <br /> I I m wo <br /> I ii I 9 PL 3/4°z20 z 2'-0' w <br /> STEEL FRAME I ,SP1.3 <br /> o <br /> SEE DETAIL 11/SP1.3 I I a w <br /> I I w o <br /> I I I I a s <br /> I I � <br /> 16'DIA.PILE I I I 2 I w <br /> 16"DIA.PILE I <br /> I I <br /> 2'-6'OR 3'-O° SEE PLAN <br /> SEE PLAN <br /> SCALE 3/4°=1'-0" PILE DETAIL AT END PILE W/CANTILEVER BEAM SCALE:3/4°=1'-0° <br /> 05 TYP. SECTION WITH PILE SUPPORT AT 'MH' ® PLAN AT INTERMEDIATE PILE o <br /> �s o <br /> \ 4'_0° p t n s <br /> / 1 1'-4 1/8' V-3 3/4" V-4 1/8° <br /> 1 T.O.STEEL ELEV. MH r� <br /> ' 12'S.S.UNE — _ PER CIVIL REF-SEE CIVIL Y--103 <br /> TYPICAL <br /> 3/16° 12'S.S LINEDAM EA END SAND BED FOR SS /, \ <br /> SEE 5/SP1.3 (2)1"DIA.z 12"M.B. — — — — — — �/ <br /> L 6x4z5/16(LLV)x 5'-0°LONG �/ \\ I \ W^� U\ 5" 6" 5" ii a EACH SIDE®10'-0'ON CENTER 4"DIA.HOLE <br /> /\ \ %t i° AND®EACH END OF BEAMS 3`� \ FOR GROUTING L _ J h� <br /> (5'-0"GAPS) �\ — — — <br /> 3. 3. • -- ———— <br /> TYP. 1/2" 1/2" <br /> 2°®24" WI4x \\ O Q <br /> RE:PLAN \ /i hK �I bA <br /> \\ C6x&2(TYP.) rT✓, �" <br /> PL 3/4'x20 x 2'-0" 48'DIAMETER W .. <br /> I WI4z 8" I .* a EVELING NUi(TYP.) \ HOPE MAN HOLE <br /> 2°10 4"DRY PACK GROUT I RE:FLAN C6x8.2 FRAME V! <br /> APPLY CORROSION PROTECTION TO M.B. I /� <br /> PL 3/4z20 z 2-Cr TYP. &WELD AFTER WELD COMPLETED 3 2"TO 4"DRY PACK I I--I <br /> I 3/16' SP1.3 <br /> T�• PL SIM TO DETAIL <br /> I (2)1'DIA z 12"M.B. 2'TO 4'DRY PACK GROUT 8&10/SP1.3 GROUT TYPICAL PL 1x20 x 2'-0" <br /> (2)1"DIAMETER z 16"M.B. <br /> (2)1'DIA.x 12"M.B. <br /> 6 POINTS OF SUP ORT <br /> 16"DIA.PILE 16°DIA.PILE <br /> PLAN VIEW ®MAN HOLE PERMETER <br /> i 16"DIA.PILE <br /> SCALE 3/4"=1'-O" SCALE 3/4'=1'-0" SCALE:3/4'=1'-0" SCALE:3/4°=1'-0° S P 1 <br /> 09 TYPICAL PILE DETAIL @ SS LINE 10 TYPICAL SECTION 11 STEEL FRAME & PILE SUPPORT 12 STEEL FRAME & PILE SUPPORT <br />