My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 SEINER DR SOUTH FORK BAKING COMPANY 2025-08-05
>
Address Records
>
SEINER DR
>
1410
>
SOUTH FORK BAKING COMPANY
>
1410 SEINER DR SOUTH FORK BAKING COMPANY 2025-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 9:54:40 AM
Creation date
6/18/2025 2:28:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Tenant Name
SOUTH FORK BAKING COMPANY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP171 <br />Page 3 of 10 <br />* Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression <br />is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw <br />Deflector. special request. ESCUTCHEON PLATE SEATING 4 - Bulb 6 - Deflector* <br />SURFACE <br />1/2" NPT* <br />UPRIGHT <br />7/1 3 <br />m <br />11,1 ram) <br />MAKE -IN <br />40MINAL 2-3/16" 2 <br />55,6 mm) <br />2-3/16" 1-1/2 <br />4 <br />(55,6 mm) (38,1 mm) <br />� 5 <br />WRENCH 6* <br />* STYLE 10 or 20 � p_7/g^ (73,0 ram) DIA. <br />FLATS RECESSED <br />PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION <br />ALL FINISHES EXCEPT POLY -STAINLESS <br />WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature <br />FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated <br />\ I SURFACE 4 - Bulb 6- Deflector* on Deflector. <br />7/1 3 <br />m <br />(11,1 ram) - <br />NOMINAL 2-3/16" — 2 <br />MAKE -IN (55,6 mm) <br />_ 2-3/16" 4 <br />38,1 /ram) <br />55,6 ram) 5 <br />12 <br />6* <br />STYLE 10 2-7/8" (73,0 mm) DIA. <br />RECESSED <br />UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION <br />POLY -STAINLESS FINISH ONLY <br />FIGURE 3 <br />QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT —SPRINKLERS <br />5.6 K-FACTOR, 112 IN. NPT <br />Installation <br />The TYCO Series TY- FRB 2.8, 4.2, 5.6, <br />and 8.0 K-factor Upright, Pendent, and <br />Recessed Pendent Sprinklers must <br />be installed in accordance with this <br />section. <br />General Instructions <br />Do not install any bulb type sprinkler <br />if the bulb is cracked orthere is a loss <br />of liquid from the bulb. With the sprin- <br />kler held horizontally, a small air bubble <br />should be present. The diameter of the <br />air bubble is approximately 1/16 in. <br />(1,6 mm) for the 135°F (57°C) and <br />3/32 in. (2,4 mm) for the 286°F (141°C) <br />temperature ratings. A leak -tight 1/2 in. <br />NPT sprinkler joint should be obtained <br />by applying a minimum -to -maximum <br />torque of 7 to 14 lb-ft (9,5 to 19,0 N-m). <br />A leak tight 3/4 in. NPT sprinkler joint <br />should be obtained with a torque of <br />10 to 20 lb-ft (13,4 to 26,8 N-m). Higher <br />levels of torque can distort the sprinkler <br />inlet and cause leakage or impairment <br />of the sprinkler. Do not attempt to com- <br />pensate for insufficient adjustment in <br />the escutcheon plate by under- or over - <br />tightening the sprinkler. Re -adjust the <br />position of the sprinkler fitting to suit. <br />Series TY-FRB Upright and Pendent <br />Sprinklers <br />The Series TY-FRB Upright and <br />Pendent Sprinklers must be installed <br />in accordance with the following <br />instructions: <br />Step 1. Install pendent sprinklers in the <br />pendent position. Install upright sprin- <br />klers in the upright position. <br />Step 2. With pipe thread sealant <br />applied to the pipe threads, hand - <br />tighten the sprinkler into the sprinkler <br />fitting. <br />Step 3. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type 6 <br />Sprinkler Wrench (Ref. Figure 14). With <br />referenceto Figure 1 to Figure 5, apply <br />the W-Type 6 Sprinkler Wrench to the <br />sprinkler wrench flats. <br />Series TY-FRB Recessed Pendent <br />Sprinklers <br />The Series TY-FRB Recessed Pendent <br />Sprinklers must be installed in accor- <br />dance with the following instructions: <br />Step 1. After installing the Style 10, 20, <br />30, or 40 Mounting Plate, as applica- <br />ble, over the sprinkler threads and with <br />pipe -thread sealant applied to the pipe <br />threads, hand -tighten the sprinkler into <br />the sprinkler fitting. <br />Step 2. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type <br />7 Recessed Sprinkler Wrench (Ref. <br />Figure 15). With reference to Figure 1 to <br />4, apply the W-Type 7 Recessed Sprin- <br />kler Wrench to the sprinkler wrench <br />flats. <br />Step 3. After the ceiling is installed or <br />the finish coat is applied, slide on the <br />Style 10, 20, 30, or 40 Closure over <br />the Series TY-FRB Recessed Pendent <br />Sprinkler and push the Closure overthe <br />Mounting Plate until its flange comes in <br />contact with the ceiling. <br />
The URL can be used to link to this page
Your browser does not support the video tag.