Laserfiche WebLink
r <br /> Finally!! We hopefully have all the details you need to approve our permit for 1410 Seiner Drive Suite 103 (M2305- <br /> 055). Attached is the response to your corrections and the updated plan set. I have added all structural calculation reports to <br /> the plan set. If you need the individual reports, I can send them to you,just let me know. <br /> I have(2)sets of paper drawings and an application for the hood to apply for a separate permit and will get that up to you this <br /> week. <br /> Please let me know if you have any other questions. <br /> Thank you! <br /> Lisa <br /> Lisa L Cassaday,Projects Advisor I Vital Mechanical Service <br /> Phone 206.629.4828 I Cell 206.795.7855 I lisa.cassadav(cavitalmechanical.com <br /> From: Drew Martin<dmartin@everettwa.gov> <br /> Sent:Friday,June 2,2023 4:13 PM <br /> To: Lisa Cassaday<lisa.cassadav@vitalmechanical.com> <br /> Subject:City of Everett Permit Services: 1410 Seiner Drive,Suite 103 (M2305-055)-Second Building Review <br /> Hello, Lisa <br /> We have completed a second review of this project. However,the previously issued comments in the First Review <br /> letter have generally not been addressed. The previous letter is attached for your convenience. <br /> Comments supplementing the previous comments are provided below;the previous comments should be addressed <br /> as indicated. Revised construction-level documents should be submitted for review. Two complete sets of the <br /> revised drawings should be submitted to replace the previously submitted drawing sets. The resubmittal documents <br /> should include an itemized response letter clarifying how the review comments below have been addressed. <br /> Supplemental Review Comments: <br /> 1. The structural modifications are not included in Permit No. B2210-001 as specified in the response. In <br /> addition, it is anticipated that modifications to the roof system may be required pending an analysis as <br /> addressed in Comment 3. <br /> 2. The Type I hood is still included in the drawings. Note that the response incorrectly refers to Type II <br /> hoods. Type I hoods require separate permit application. <br /> 3. The original roof design under Permit No. B2107-074 does not include the weight of the mechanical units in <br /> the design. Calculations substantiating the roof framing to support the unit weights in additional to dead and <br /> snow loading are required. If modifications to the roof structure are required,these must be submitted under <br /> a separate permit application or as a revision to B2107-074. Note that Permit No. B2209-019 and B2210-001 <br /> were also reviewed and do not address this issue. <br /> 4. Design and details for the suspended units are not included in the associated Building permits and must be <br /> addressed in the Mechanical permit application. <br /> Review of your project will be performed in the order received once the required documentation has been <br /> submitted. Please let me know if you have questions. <br /> Drew Martin,P.E.,S.E. <br /> L Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street,2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/T:8 am-12 pm &1 pm-3 pm;Tu: 1:oopm-3:00pm <br /> 2 <br />