Laserfiche WebLink
A PORTION OF THE NW 114 OF THE NE 114 OF SEC. 14, TWP. 28 N, R. 4 E, W.M. CITY OF EVERETT, SNOHOMISH COUNTY, WASHINGTON <br /> ONE-LINE, POWER, AND LIGHTING SYMBOLOGY <br /> Z r'(X CEILING/PENDANT/BOLLARD MOUNTED LUMINAIRE,LAMP TYPE AS <br /> .( SPECIFIED PLUG-IN RECEPTACLE STRIP,QUANTITY AND SPACING <br /> p X p X LOW VOLTAGE CIRCUIT BREAKER(CB). RATING 7 1/2 OR HP MOTOR WITH DESIGN HORSEPOWER Y ®(WHEN INDICATED) X CEILING/PENDANT/BOLLARD MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED, OF RECEPTACLES AS NOTED OR SPECIFIED <br /> \I 20A OR \)100AF AND NO.OF POLES AS SHOWN.WHEN SPECIFIC Z� EMERGENCY(INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED) X un <br /> o/3P o/80AT TYPE,OTHER THAN MCCB,IS REQUIRED,X Y SPECIAL-PURPOSE RECEPTACLE AS DEFINED ON PLANS Z o <br /> 3P INDICATES TYPE. X Y O <br /> WALL MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED X <br /> TYPES: TRIP UNIT: Y X OR X TWO RECEPTACLES IN 2-GANG BOX UNDER COMMON COVER j <br /> MCCB- MOLDED CASE L - LONG TIME PICKUP Z PQQ Y Y PLATE c <br /> ICCB - INSULATED CASE S- SHORT TIME PICKUP O GENERATOR X WALL MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED,EMERGENCY Y <br /> W LVP - LO VOLTAGE POWER I - INSTANTANEOUS PICKUP <br /> MCP - MOTOR CIRCUIT G- GROUND FAULT PICKUP Z Y (INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED) X DUPLEX RECEPTACLE <br /> PROTECTOR A- ARC ENERGY REDUCTIO Y <br /> (RATING PER CONNECTED MODE X <br /> LOAD) o TRANSFER SWITCH,CURRENT RATING,AND Y WALL MOUNTED FLOOD LUMINAIRE,LAMP TYPE AS SPECIFIED X <br /> [/p NUMBER OF POLES AS NOTED Z Te SIMPLEX RECEPTACLE <br /> }___ INTERLOCK: X-INDICATES TYPE V ATS ATS-AUTOMATIC X Y Q <br /> TYPES: MTS-MANUAL Z Y POLE/STANCHION MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED X <br /> E-ELECTRICAL Z � RECESSED FLOOR MOUNTED BOX,QUANTITY AND TYPE OF <br /> M-MECHANICAL I y RECEPTACLES AS INDICATED z <br /> K-KEY llJ..l� TRANSFORMER X POLE/STANCHION MOUNTED LUMINAIRE LAMP TYPE AS SPECIFIED SUBSCRIPTS: <br /> y EMERGENCY(INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED <br /> GFP GROUND FAULT PROTECTION 3-PHASE,3-WIRE DELTA CONNECTION Z X-INDICATES TYPE <br /> X GFCI-GROUND FAULT CIRCUIT INTERRUPTER <br /> Y1 3-PHASE,4-WIRE GROUNDED WYE CONNECTION ♦D POLE/STANCHION MOUNTED FLOOR LUMINAIRE,LAMP TYPE AS SPECIFIED IG-ISOLATED GROUND <br /> Z Y TR-TAMPER RESISTANT <br /> 52 MEDIUM VOLTAGE CIRCUIT BREAKER PLH-PLUG LOAD HALF CONTROLLED <br /> LP100 SWITCHBOARD OR PANELBOARD;NAME,VOLTAGE, Z�X CEILING/PENDANT MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED PLO-PLUG LOAD DUAL CONTROLLED <br /> 2081120 Y USB-USB CHARGING STATION <br /> 30,4W PHASE,NUMBER OF WIRES WHEN INDICATED SPD-SURGE PROTECTIVE DEVICE rv_ <br /> FUSE,RATING,AND NUMBER OF FUSES AS NOTED Y-INDICATES CIRCUIT NUMBER FROM PANELBOARD <br /> Z[_ Y WALL MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED <br /> FUSED CUTOUT,CURRENT RATING,FUSE RATING, 100 I �� CONDUIT TURNING UP <br /> AND QUANTITY AS NOTED KVA NON-MOTOR LOAD WITH DESIGN KVA,KW,OR AMP X CEILING/PENDANT MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED,ALL OR <br /> Z�Y PARTIAL EMERGENCY(INTERNAL OR EXTERNAL POWER SOURCE AS CONDUIT TURNING DOWN <br /> INDICATED <br /> FUSIBLE SWITCH,CURRENT RATING,FUSE X (#� HOMERUN TO SOURCE(E.G.PANELBOARD,MCC) <br /> RATING,AND QUANTITY AS NOTED(3 POLE VOLTAGE TRANSFORMER(VT,PT,OR CPT) ZQN Y WALL MOUNTED LUMINAIRE,LAMP TYPE AS SPECIFIED,ALL OR PARTIAL NUMBER IN PARENTHESES REPRESENTS CONDUCTOR SIZE <br /> ION) EMERGENCY(INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED OTHER THAN#12 <br /> SINGLE PHASE:2#12,1#12G IN 3/4'C <br /> NON-FUSED SWITCH,CURRENT RATING,AND THREE PHASE:3#12,1#12G IN 3/4"C <br /> NUMBER OF POLES AS NOTED(3 POLE DON) CURRENT TRANSFORMER(CT) �X EMERGENCY LIGHT,NUMBER OF ATTACHED HEADS AS SHOWN UNLESS OTHERWISE NOTED,CONDUCTOR SIZE IS FOR <br /> Y ENTIRE CIRCUIT,SOURCE TO LAST DEVICE.ALSO,SEE ONE <br /> DISCONNECT OR DRAWOUT CONNECTION X LINE DIAGRAM FOR CIRCUIT REQUIREMENTS <br /> O iY EMERGENCY LIGHT,REMOTE MOUNTED HEAD CONDUIT CONNECTION TO EQUIPMENT <br /> WH UTILITY WATT-HOUR METER PER UTILITY REQUIREMENTS <br /> z X X DOUBLE-FACED CEILING OR WALL MOUNTED EXIT LIGHT; CIRCUIT RUN BETWEEN DEVICES EXPOSED IN <br /> MAGNETIC MOTOR STARTER AND SEPARATELY y Y DIRECTIONAL ARROWS(IF REQUIRED)AS INDICATED ON PLANS NON-ARCHITECTURALLY FINISHED AREAS;CONCEALED <br /> A U & A U MOUNTED COMBINATION MAGNETIC MOTOR IN ARCHITECTURALLY FINISHED AREAS.CONDUIT AND <br /> B B STARTER DMP DIGITAL METERING PACKAGE CONDUCTOR SIZES SHALL BE THE SAME AS THE — <br /> ®X X SINGLE-FACED CEILING OR WALL MOUNTED EXIT LIGHT; HOMERUN FOR THE CIRCUIT. U <br /> y H Y DIRECTIONAL ARROWS(IF REQUIRED)AS INDICATED ON PLANS <br /> MOTOR/LOAD CONTROLLER AND SEPARATELY MOUNTED LIGHTING FIXTURE SUBSCRIPTS: Q <br /> D U & D U MOTORILOAD CONTROLLER WITH SHORT CIRCUIT - CONDUIT RUN BETWEEN DEVICES CONCEALED IN L_- <br /> PROTECTION AND DISCONNECT GROUND X-INDICATES LUMINAIRE TYPE PER LUMINAIRE SCHEDULE NON-ARCHITECTURALLY FINISHED AREAS OR UNDER <br /> Y-INDICATES CIRCUIT NUMBER FROM PANELBOARD FLOOR SLAB.CONDUIT AND CONDUCTOR SIZES SHALL <br /> I Z-INDICATES CONTROLLING SWITCH(IF REQUIRED) BE THE SAME AS THE HOMERUN FOR THE CIRCUIT. <br /> MOTOR STARTER AND CONTROLLER SUBSCRIPTS: b NL-NIGHT LIGHT UNSWITCHED <br /> LIGHTNING ARRESTER CIRCUIT HASH MARKS(WHEN INDICATED);LONG, (n z <br /> A-MAGNETIC STARTER NEMA SIZE LIGHTNING SHORT,SINGLE DOT,AND DOUBLE DOT REPRESENT Z Ln — <br /> X WALL SWITCH PHASE,NEUTRAL,EQUIPMENT GROUND,AND ISOLATED z <br /> B-STARTER TYPE SUBSCRIPTS: (#X) EQUIPMENT GROUND,RESPECTIVELY.XREPRESENTS Q <br /> NDUCTOR SIZE OTHER THAN#12 IN 3/4"CONDUIT. <br /> NONE - FULL VOLTAGE NON-REVERSING(FVNR) S CO W <br /> PD LOW VOLTAGE SURGE PROTECTIVE DEVICE X-INDICATES TYPE (� Q <br /> FVR - FULL VOLTAGE REVERSING NONE - SINGLE POLE 1 <br /> 2S - TWO SPEED 2 - DOUBLE POLE CIRCUIT CONTINUATION Q <br /> RVAT - REDUCED VOLTAGE AUTO TRANSFORMER SS SELECTOR SWITCH 3 - THREE-WAY <br /> 4 - FOUR-WAY CONDUIT STUBBED OUT AND CAPPED _\ <br /> C-CONTROL DIAGRAM OR CONTROLS K - KEY SWITCH <br /> SCHEDULE NUMBER(IF REQUIRED) PB PUSHBUTTON P - PILOT LIGHTL LIGHTED z W <br /> D-CONTROLLER TYPE DM - D MMING HANDLE Q <br /> CORD AND PLUG CONNECTION <br /> VFD - VARIABLE FREQUENCY DRIVE IC INSTRUMENTATION/CONTROL DEVICE MT - TOMENTARY CONTACT <br /> ER <br /> SS - SOLID STATE Y-INDICATES CONTROLLING SWITCH(IF REQUIRED) > L <br /> CONT - CONTACTOR OR O <br /> SV SOLENOID VALVE XXX XXX CONDUIT TAG OR CIRCUIT NUMBER-WIRE <br /> Y AND CONDUIT SIZE AS SPECIFIED IN CIRCUIT O <br /> MANUAL MOTOR STARTER <br /> SEPARATELY MOUNTED COMBINATION MOTOR STARTER X SCHEDULE ON THE SHEETS C� <br /> IL�J OR CONTROLLER;SEE ELECTRICAL ONE-LINE DIAGRAM CONTROL PANEL INTEGRAL OR PROVIDED WITH ASSOCIATED EQUIPMENT SUBSCRIPTS: <br /> OR SCHEDULE FOR DESCRIPTION X-INDICATES TYPE <br /> HP - HORSEPOWER RATED GROUND CABLE W <br /> �I CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL OR PROVIDED TE - HORSEPOWER RATED WITH THERMAL ELEMENT <br /> SEPARATELY MOUNTED MOTOR STARTER OR CONTROLLER; L� WITH ASSOCIATED EQUIPMENT FT - HORSEPOWER RATED WITH FUSETRON FUSE GROUND ROD u <br /> SEE ELECTRICAL ONE-LINE DIAGRAM OR SCHEDULE FOR Y-INDICATES SWITCH TYPE <br /> DESCRIPTION. -JO OR JO JUNCTION OR PULL BOX NONE TOGGLE SWITCH TYPE <br /> - ROTARY SWITCH TYPE <br /> �I GENERAL NOTES: <br /> PANELBOARD(250V TO 600V) PC PHOTOCELL W <br /> uX NON-FUSED SAFETY SWITCH,30A,3P,X 1. THIS IS A STANDARD ELECTRICAL SYMBOLOGY SHEET. NOT <br /> INDICATES AMP RATING GREATER THAN 30A PANELBOARD(LESS THAN 250V) ALL SYMBOLS MAY BE USED ON THIS PROJECT. <br /> TC TIME CLOCK <br /> X� FUSED SAFETY SWITCH,3P,X INDICATES AMP RATING ELECTRICAL EQUIPMENT ENCLOSURE:SWITCHBOARD,MOTOR 2. SCREENING OR SHADING OF WORK IS USED TO INDICATE <br /> �� GREATER THAN 30A, ,CONTROL PANEL,TRANSFORMER OR OTHER 1 EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSED <br /> zLy 0 ` IMPROVEMENTS TO HIGHLIGHT SELECTED TRADE WORK. 14 HAA' <br /> EQUIPMENT AS INDICATED. ESTIMATED SIZE AS INDICATED. �{OSX OR OSX LIGHTING CONTROL OCCUPANCY SENSOR,WALL MOUNTED, REFER TO CONTEXT OF EACH SHEET FOR USAGE O`'' <br /> . S <br /> WHEN USED X INDICATES EQUIPMENT TYPE. X INDICATES SPECIFIC TYPE AS SPECIFIED Q.�pF WASHi <br /> 3. SEE P&ID LEGEND SHEET FOR PROJECT SPECIFIC EQUIPMENT yP goy <br /> SEPARATELY MOUNTED CIRCUIT BREAKER;SEE EQUIPMENT TYPES: SYMBOLS,EQUIPMENT ABBREVIATIONS,AND PIPING SYSTEM <br /> CB ELECTRICAL ONE-LINE DIAGRAM OR SCHEDULE OSX LIGHTING CONTROL OCCUPANCY SENSOR,CEILING MOUNTED, ABBREVIATIONS. <br /> ATS - AUTOMATIC TRANSFER SWITCH O X INDICATES SPECIFIC TYPE AS SPECIFIED <br /> FOR DESCRIPTION CP - CONTROL PANEL <br /> MTS - MANUAL TRANSFER SWITCH OX ROOM/AREA LIGHTING CONTROL TYPE, <br /> MCC - MOTOR CONTROL CENTER SEE LIGHTING CONTROL SCHEDULE FOR REQUIREMENTS S/ONAI 17"C, <br /> UPS - UNINTERRUPTIBLE POWER SUPPLY <br /> a VFD - VARIABLE FREQUENCY DRIVE a <br /> E SB - SWITCHBOARD LOW VOLTAGE DIGITAL WALL SWITCH,NUMBER INDICATES JOB NUMBER: C21-180 <br /> SG - SWITCHGEAR QUANTITY OF PUSH BUTTONS PER SINGLE GANG PLATE,LETTER DRAWING NAME: <br /> T - TRANSFORMER INDICATES CONTROL ZONE WHEN SHOWN DESIGNER: <br /> DRAFTING BY: <br /> DATE: 01 31 2022 <br /> s SCALE: AS INDICATED <br /> UTILITY NOTE DISCLAIMERJURISDICTION: EVERETT <br /> i THE CONTRACTOR SHALL VERIFY THE THE TOPOGRAPHIC SURVEY WAS PERFORMED BY LDC, INC.IN SEPTEMBER O O <br /> LOCATION OF ALL EXISTING UTILITIES 2021.ANY CHANGES TO THE SITE AFTER THIS DATE WILL NOT BE <br /> PRIOR TO ANY CONSTRUCTION. REFLECTED IN THE PLANS.ANY DISCREPANCIES FOUND BETWEEN WHAT IS Cal 2 Business Days Before You Dig <br /> AGENCIES INVOLVED SHALL BE NOTIFIED SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE 811 or 1-800-424-5555_ WITHIN A REASONABLE TIME PRIOR TO BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. <br /> THE START OF CONSTRUCTION. Utilities Underground Location Center SHEET OF <br />