Laserfiche WebLink
INSTRUCTIONS FOR HEATING EQUIPMENT SIZING FORM <br /> Building Code Section 1204.1 and Residential Code Section R303.8 establish a minimum required heating output,and <br /> Energy Code Sections 503.2.2 and 1422/1431.2 specify a maximum allowed heating equipment output. <br /> General Information: <br /> This form is recommended for sizing the heating systems for all residential buildings. It may be used for commercial buildings where appropriate. <br /> This form,or acceptable alternate calculations,must be completed for each dwelling unit. A separate copy shall be attached to each set of drawings <br /> submitted with the building permit application and over-the-counter(OTC)permit application. <br /> If new or enlarged electric service is to be installed in an existing building,you may be subject to additional Seattle City Light requirements. <br /> For further information,contact Seattle City Light at 206-615-0600 if the project is north of Denny Way or 206-386-4200 if the project is south of Denny <br /> Way. <br /> Detailed Instructions(step numbers match the numbers shown on the front of the form): <br /> -For existing buildings,complete for each dwelling unit as proposed after remodeling. If space heating equipment is simply being replaced,complete for <br /> the dwelling unit as existing. <br /> -For new construction,complete for each dwelling unit as proposed. Values in bold are Prescriptive requirements for single-familylduplex. <br /> (1)On the line with the appropriate description: <br /> -For components A-E,enter the square footage for windows,skylights,sliding glass doors,opaque doors,opaque roof/ceiling(minus skylights), <br /> opaque wall(minus windows and doors),floor over unheated space. <br /> -For component F,enter the linear feet of perimeter for slab-on-grade floor(less than two feet below grade),not the square footage area of the slab. <br /> -For component G,enter the linear feet of perimeter for basement floor(more than two feet below grade). Do not enter if the basement is unheated. <br /> -For component H,enter the volume in cubic feet of the interior heated space based on when the dwelling unit or portion thereof was or will be built. <br /> For glazing and doors,where U-factors different from those specified are used,enter those U-factors in the blanks provided for that category.For <br /> other components,where R-values different from those specified are used,enter that value and the corresponding U-factor or F-factor in the blanks <br /> provided in that category.For all new entries,multiply the U-factor or F-factor by the 46°F.design temperature difference(70°F.-24°F.)to obtain the <br /> corresponding heat loss factor and enter that value in the Heat Loss Factor column. <br /> (2)Multiply the heat loss factor by component square feet(sq.ft),linear feet(lin.ft.)or cubic feet(cu.ft),as appropriate to obtain the component heat loss. <br /> (Automated in the electronic version of this form.] <br /> (3)Add all entries to obtain the total which is the Design Heating Load(DHL). (Automated in the electronic version of this form.] <br /> (4)Enter the heated floor area of the dwelling unit,then divide the DHL by the heated floor area to obtain the load on a square foot basis. <br /> (Note that typical values for new construction are 8 Btuh/SF or 2.5 Watts/SF.) <br /> (5)To determine the allowable heating equipment output range: <br /> -Multiply Design Heating Load(in either Btuh or Watts)by 1.0 to obtain minimum size required by the Building Code(Section 303.8) <br /> -Multiply Design Heating Load(in either Btuh or Watts)by 1.5 to obtain maximum allowed by the Energy Code(Section 503.2.2/1422/1431.2) <br /> (Note that,for nonresidential buildings,there are no minimum Building Code requirements and the maximum Energy Code allowance is 150%of the <br /> DHL.) <br /> (Automated in the electronic version of this form.] <br /> (6)Enter proposed equipment size(output)and efficiency. The proposed equipment output must be within the minimum and maximum allowed. <br /> Note that Energy Code Section 503.2.2, <br /> -Exception 2 exempts natural gas-and oil-fired space heating equipment whose total rated space heating output in any one dwelling unit is <br /> 40,000 Btulh or less from the sizing limit. <br /> -Exception 4 exempts electric resistance heaters under 2 kW from the sizing limit. <br /> (Note that there are no exceptions from the 150%sizing limit for high-efficiency equipment or for any other systems,such as heat pumps.) <br /> Seattle DPD,2009sec-HeatingEquipmentSizingForm.xls,January 2011 <br /> download from the Seattle Energy Code website residential forms page at http://www.seattle.gov/dpd/energylformsres.htm • <br />