Laserfiche WebLink
CONCRETE <br />l ILJI 1I 1& A s s o c i a t e s I no REPORT NO.: 0962130SCROS0322JM -3 <br />Geotechnical Engineering a Environmental Engineering <br />Construction Testing and Inspection <br />DATE: 6/3/2022 CONTRACTOR: Shelter Holdings <br />PROJECTM 09621305 PERMITM B2003.013 <br />PROJECT: Riverfront Bldg A INSPECTOR: Josh Mirabella <br />LOCATION: 3910 Riverfront Blvd JURISDICTION: City of Seattle <br />KA P.M.: Jeff Mercer WEATHER: rainy TEMP: 66 ° <br />Field Data r� <br />Concrele:1— yeS Other: L� <br />Supplier[ Cadman Plant No. 34 site Ma: no <br />Ticket# %Air <br />Location: <br />Slump Mix Air Unit <br />Area <br />in #57 <br />Remarks: Jeff Dewey wrote the DFR for this inspection <br />Plaeee serer To Field Repol Number: 09621306DFR632022JD <br />Inspector :I Josh Mirabella <br />Reported Batch DATA <br />Cement Type 2L <br />Design Actual <br />&W No. P3D40428 0 <br />cem. Lbs. Vessel PLC 546 <br />F Ash Its. Fly Ash 105 <br />C. Agg. Lbs #57 1606 <br />e. An. Lbs #8 297 <br />C. Agg. Lbs <br />Sandtbs Sand 1223 <br />Water <br />AdrMrNre POZZ 80 6 <br />Adcrust,eel Glen 75001 23 <br />Atlmpture <br />Air Ent <br />(Oi/avl.) <br />Water Added On Job Site <br />(Gals.) u <br />ASTM <br />Method <br />C172 <br />C1 <br />H <br />C3 <br />C1084 <br />C231 <br />C31 <br />Other <br />Laboratory Data <br />Design Strength: <br />5000 @ 28 days <br />Date Specimens Rec'd: 1 616/2022 <br />Cyl. <br />Code <br />Test <br />Date <br />Field <br />Cure <br />Age <br />Dia. <br />Area <br />Wt. <br /># <br />Max <br />Load <br />Comp. <br />Strength <br />Set <br /># <br />Tested <br />By <br />ark <br />Typ <br />Test Method <br />ASTM C39 <br />78691-1 <br />6/10/22 <br />7 <br />4.00 <br />12.57 <br />- <br />70260 <br />5590 <br />3 <br />DL <br />2 <br />ASTM C109 <br />78591-2 <br />7/1/22 <br />28 <br />4.00 <br />12.57 <br />- <br />99200 <br />7890 <br />3 <br />DL <br />2 <br />ASTM C617 <br />78591-3 <br />7/1/22 <br />28 <br />4.00 <br />12.67 <br />- <br />97730 <br />7770 <br />3 <br />DL <br />2 <br />ASTM C1231 <br />78591-4 <br />7/1/22 <br />28 <br />4.00 <br />12.67 <br />- <br />98110 <br />7810 <br />3 <br />DL <br />2 <br />ASTM C1019 <br />78591-5 <br />7/1/22 <br />28 <br />4.00 <br />12.57 <br />- <br />99040 <br />7880 <br />3 <br />DL <br />2 <br />OTHER <br />78591-6 <br />6/6122 <br />X <br />31 <br />4.00 <br />12.57 <br />- <br />48550 <br />3860 <br />3 <br />TK <br />2 <br />78591-7 <br />6/6/22 <br />X <br />3 <br />4.00 <br />12.57 <br />49410 <br />3930 <br />3 <br />TK <br />2 <br />78591-8 <br />8/6/22 <br />X <br />3 <br />4.00 <br />12.57 <br />49060 <br />3900 <br />3 <br />TK <br />2 <br />Test Results <br />Remarks: <br />Results Reviewed By: <br />Date: <br />/ -1-7— <br />Conforming <br />Codes for Break <br />Types: <br />Jii <br />L <br />1 <br />f <br />�' t I <br />2 <br />3 <br />� <br />� <br />4 <br />w <br />11JI <br />5 <br />6 <br />concrete Report <br />Offices Serving <br />The Western United States <br />Elfac*e 1T IW020 <br />Lynnwood (425) 485-5519 a Poulsbo (360) 598-2126 a Tacoma (253) 939-2500 <br />sti aryvr aaxe°.sa�.»+xm�+b.w..xbs oredeie..r.wmnmxbamrasn.ys.em.iw sev.emp/mrs°+.ruwser/vaw.n.en.mur. nr�w+nmw.wwv�'aro..�.�we°xv °.n nw.�r,.w vw <br />H9 W'Als KG4w iM HavYq�b Wyxi la�rlm'pisbCW eMtIA 0/[pvy lV �aotw F¢palaha Msxglrtya4iry anffi/dnwla 1KumiGynW"a�hrva YinpoAfAp/[Ynsrri W. <br />