Laserfiche WebLink
mv CONCRETE <br />{.ILJa 1& A s s o c i a t e S, Inc. REPORT NO.: 0962130SCROB0322JM -3 <br />Gwilechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />DATE: 6/3/2022 CONTRACTOR: Shelter Holdings <br />PROJECT#:09621305 PERMIT#: B2003-013 <br />PROJECT: Riverfront Bldg A INSPECTOR: Josh Mirabella <br />LOCATION: 3910 Riverfront Blvd JURISDICTION: City of Seattle <br />KA P.M.: Jeff Mercer WEATHER: rainy TEMP: 66 ° <br />Field Data <br />Concrete: yes = Other. <br />Supplier: Cadman Plant No. 34 site Mix: no <br />Slump Mix Air Unit <br />Time Truck# Ticket# %Air Inch Temp(F) Temp(F) Weight <br />9:45 358 1280700 1.5% 6.5 <br />Location: <br />rlacemertt <br />17line, second level. <br />Remarks: Jeff Dewey wrote the DFR for this inspection <br />Please Refer To Field Repot Number: 09621305DFR632022JD <br />Inspector :I Josh Mirabella <br />Reported Batch DATA <br />Cement Type 2L <br />Destan Actual <br />Mh <br />Cem.I <br />F. Ash <br />C. A, <br />C Agg. <br />C. Agg. <br />Sara <br />Air Ent <br />#57 <br />546 <br />23 <br />Water Added On Job Site <br />(Gals.) L0 <br />ASTM <br />Method <br />C172 <br />C143 <br />N <br />C3 <br />G )64 <br />C231 <br />C31 <br />Other <br />Laboratory Data <br />Design Strength: <br />5000 C 28 days <br />Date Specimens Rec'd: 616/2022 <br />Cyl. <br />Code <br />Test <br />Date <br />Field <br />Cure <br />Age <br />Dia. <br />Area <br />wt. <br /># <br />Max <br />Load <br />Comp. <br />Strength <br />Set <br /># <br />Tested <br />By <br />Brk <br />Typ <br />Test Method <br />ASTM C39 <br />78591-1 <br />6/10/22 <br />7 <br />4.00 <br />12.57 <br />- <br />70260 <br />5590 <br />3 <br />DL <br />2 <br />ASTM C109 <br />78591-2 <br />7/1122 <br />28 <br />4.00 <br />12.57 <br />- <br />99200 <br />7890 <br />3 <br />DL <br />2 <br />ASTM C617 <br />78591-3 <br />7/1/22 <br />28 <br />4.00 <br />12.57 <br />- <br />97730 <br />7770 <br />3 <br />DL <br />2 <br />ASTM C1231 <br />78591-4 <br />7/1122 <br />28 <br />4.00 <br />12.57 <br />- <br />98110 <br />7810 <br />3 <br />DL <br />2 <br />ASTM C1019 <br />78591-5 <br />7/1/22 <br />_ <br />28 <br />4.00 <br />12.57 <br />- <br />99040 <br />7880 <br />3 <br />DL <br />2 <br />OTHER <br />78591-6 <br />616/22 <br />X <br />3 <br />4.00 <br />12.57 <br />48550 <br />3860 <br />3 <br />TK <br />2 <br />78591-7 <br />6/6/22 <br />X <br />3 <br />4.00 <br />12.57 <br />49410 <br />3930 <br />3 <br />TK <br />2 <br />78591-8 <br />6/6/22 <br />X <br />3 <br />4.00 <br />12.57 <br />49080 <br />3900 <br />1 3 <br />1 <br />2 <br />Test Results <br />_TK_j <br />Remarks: <br />Results Reviewed By: <br />Date: <br />/ 7 <br />Conforming <br />Codes for Break <br />Types: <br />v\' <br />1 <br />w`�� <br />2 <br />I <br />3 <br />4 <br />5 <br />L J <br />6 <br />Conaele ReW <br />Offices Serving <br />The Western United States <br />EffecUv. 1V15R020 <br />Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 <br />m.re�or;Arowemu.�.roesn.roa+ar.m..�.wae.esx.wm.rmk°pm:wnay a°w..cwen..tmw +.°+a�uwwn.�mee.�w.. m�m+�x..mwam.*'. axna�un e�,vmme.Ra m.-.. k.r..o.. <br />M u.l aYs.:bt.a. Tta KavYYnb M1W I>nAw {Nb6W e1.m:'9 el N' W via �gaKwle}[4x°xara atgl�-axNd/ W wW/d m6c Ti.um FWs:'mhabenPwxah.m...mu. <br />