My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3702 W MUKILTEO BLVD C 2024 HARBORS EDGE TOWNHOMES Plans 2025-07-21
>
Address Records
>
W MUKILTEO BLVD
>
3702
>
HARBORS EDGE TOWNHOMES
>
Plans
>
3702 W MUKILTEO BLVD C 2024 HARBORS EDGE TOWNHOMES Plans 2025-07-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2025 10:51:04 AM
Creation date
6/23/2025 10:46:33 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3702
Unit
C
Tenant Name
HARBORS EDGE TOWNHOMES
Permit
K2406-008
Year
2024
Notes
INSTALL NEW RESIDENTIAL FLOW-THROUGH SYSTEM IN TOWNHOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o M <br /> A A A z <br /> E9a E9T E9a LL <br /> PLAN 1727 PLAN 1727 PLAN 1727r Q LL <br /> O <br /> a � <br /> N <br /> DESK (EGRESS) y (EGRESS) <br /> PIPING IN GARAGE TO 6E W/DISP. DW POCKET <br /> OFFICE c <br /> REVERSE-TENTED.SEE DETAIL BEDROOM BEDROOM <br /> THIS PAGE.NO INSULATION TO KITCHEN w <br /> BE INSTALLED BETWEEN PIPING O <br /> w THREE z TWO <br /> AND WARM SPACE ABOVE(TYP). Oz o i <br /> 5� 0 < <br /> L INWRILINEO O.H.DOOR J L -------------------- a <br /> �nITmRIGflTrosmoN———————————— o% o% <br /> TOP OF WINDOWS lue arc indicates dro <br /> noa.°. nwso. <br /> ATLOWERFLOOR to toilet installed by Q Q o 0 <br /> TO BE AT 7'-0" plumber(TYP) c <br /> UNLESS OTHERWISE LL PANT <br /> NOTED Rise LF-MF:1 x 10'-1 Rise LF-MF:1 x 10'-1 w Rise LF-MF:1 x 10,01 Rise LF-MF:I x 10'-1 2 2 2 2 <br /> GA��\\GE o% ow 11 ftz 11 ftz 0% 0% 11 ftz 11 ftz 11 ftz 11 ftz <br /> g� O 2 2 454 1 ftz2 3 —-, 41 ft <br /> �\// Rise MF-UF:Os/a x 9'-0 je <br /> 1 �(tI� Rise MF-UF:03k x 9'-0 A ���L\V/ 1 °� 'y <br /> p� O ,A° .N+,ACCESS •> <br /> HEAT® DINING o OWN • o DO BAT VFAN TO 6 , ��°� o U DOWN o S&WS 6 ��RING <br /> DETECTOR ——— ——— �IS ROOM_ _ 50 CFM V7n ®0% 0% TYP. <br /> TUB/SHOWER W 3 110 <br /> TOP OF WINDOWS 3 <br /> / \ AT MAIN FLOOR $ <br /> TO BE AT V-0„ v <br /> UNLESS OTHERWISE d <br /> T 3 ftz° --- --- O \� No <br /> M <br /> VTOz 43 ftz // \ co5iftz 5ft rA t 2 OCFM ios.°. a 6 FAN SYSTEM a Vi0 6 6 Eo <br /> O MINI-SPLIT u 5 CFMDUCTLES2 EC.HET 6 z a O e = 2 HAA RLERS 66P MPH 0 2 3 A2 6 6z c A a <br /> J GREAT � 8 AIR HANDLER UCTLESS MINI-SPLIT installed by w <br /> m` <br /> ROOM o% w uP 1s o% a% o o% plumber(TYP) M <br /> FOYER a 'fl y" <br /> = x 483 PRIMARY c ce LL a« <br /> N �3 <br /> BEDROOM °® a Rise MF-UF:O%x W. 93 BEDROOM Rise MF-UF:O%x 9'-O N <br /> FOUR <br /> v c i= <br /> Y 9 ..m <br /> UTDOOR DUCTLESS CONDENSER C u W L <br /> a sE <br /> COVERED f73 <br /> — --------- y F d <br /> (EGRESS) PORCH <br /> 3 <br /> a --- 3 ---- ———— 3 --- ^. �s <br /> o ` <br /> L-------- L--------L m > >� <br /> LINE OF a ABV.LINE N O n a s <br /> =a <br /> BUM <br /> U1 Y rn q <br /> ABV.P OUT GUARDRAIL 36"HIGH MIN. c _ <br /> RAILS SHALL NOT ALLOW <br /> o <br /> PASSAGE OF A SPHERE r•y H =N <br /> 41NCHES OR MORE IN f 5 <br /> DIAMETER-INSTALL PER MFG.SPECS. u `a= <br /> SEE NOTE ON S03 FOR STRUCTURAL ATTACHMENTS PROVIDED BY BTL Uj•I- y a <br /> 4' <br /> LOWER FLOOR (MIRROR) LOWER FLOOR (TYP) 4' MAIN FLOOR (MIRROR) MAIN FLOOR (TYP) UPPER FLOOR (MIRROR) UPPER FLOOR (TYP) <br /> SCALE:1/4"=V-0" SCALE:1/4"=V-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" SCALE:1/4"=1'-0" <br /> PART TAG KEYNOTES: Hanger No.17W ' ` ynFl <br /> Pl pe Strap <br /> •3/4"x 3/4"x 1/2"S x S x T Reducing Tee left for plumber to connect to toilet Pipe Strap <br /> e <br /> P P <br /> Hydraulic Information Maximum Support Spacing for Wood Screw Pipe <br /> 1'-6" OCCUPANCY <br /> CPVC Piping #12 x 1Ya" 'D #a <br /> 3' 1' OCCUPANCY CLASSIFICATION Residential Pipe Between From From O x <br /> 6 <br /> i 9 " <br /> TOTAL HEADS FLOWING 2 NFPA 13D CODE QUICK REFERENCES Size Hangers A.S. End of 01 m N 3.a <br /> 8.3 LOCATION OF SPRINKLERS: Inline Line rH c a <br /> K-FACTOR 4.9 /////// ' N H o w <br /> 8.3.1 Sprinklers shall be installed in all areas 3/a" Soh' 3' 6" # U <br /> o TOTAL WATER REQUIRED 26.74 1" 6' 4' 9" E N v p <br /> Ellexcept where omission is permitted by 8.3.2 1�/a" 6�h' S' 12" Wood Joist or Beam m� "E v y O <br /> —1'-6" TOTAL PRESSURE REQUIRED 60.662 through 8.3.8. ill, 7' 7' 12" �� w ai o t h� <br /> BASE of RISER(gpm) 26.74 2" 8' 7' 12" a'i w o N <br /> 1 8.3.2 Sprinklers shall not be required in co m o a <br /> BASE of RISER(psi) 28.177 O z 21" 9' 7' 12" o <br /> (P ) bathrooms of 55 ft and less. 3" 1 10' 1 7' 12" Hanger No.19W Lr) T E o w <br /> RANGE FIREPLACE UN-INSULATED DUCT UN-INSULATED HOT WATER PIPE SAFETY MARGIN(psi) +56.292(48.1%) Offset Pipe Hanger }Q @� o w v w <br /> 8.3.3 Sprinklers shall not be required in clothes <br /> 2 sprinklers in the design area flowing 13 gpm minimum for 16x16 closets,linen closets,and pantries that meet all Hanger No.09W Pipe ^a, M O N <br /> spacing per NFPA 13D and the sprinkler's listing.Refer to the Pipe Strap LU M Z ,v Ln <br /> 2'-0" sprinkler listing for approval chart.The highest,most remote unit of the following conditions: P P UJ W ry E. <br /> v 20 <br /> p g pp g O2 (1)The area of the space does not exceed 24 ftz. Wood Screw U J E o ¢ o <br /> DIFFUSER on the parcel has been used for worst-case scenario hydraulic (2)The walls and ceilings are surfaced with #18 x 1Yz" U <br /> 6„ calculations. noncombustible or limited-combustible materials Wood Screw Pipe Offset Pipe M Q U d u v yi <br /> 1'-0" as defined in NFPA 220. #18 x 1h" Hanger Lu w <br /> WALL 6�,I �, z�, Pipe Strap —1 w Lu m n m c <br /> � �f o (Short) .—I t/) O w a to o w <br /> WFi MIN.R-11 INSULATION BATT.OVER PIPE. 8.3.4 Sprinklers shall not be required in garages, <br /> NO INSULATION TO BE O Z M <br /> 6" 3" SECURE TO ROOF TRUSS IF BLOWN IN 3 Open attached porches,Carports,and similar o <br /> INSTALLED BETWEEN PIPING ////i // //// <br /> INSULATION IS USED. Structures. <br /> AND WARM SPACE /// <br /> 01 <br /> R-11 IS A SPRINKLER PIPING TO BE /// /////////// /// /////////// _ <br /> COLD AREA TIGHT TO WARM FLOOR ABOVE 8.3.5 Sprinklers shall not be required in attics Wood Joist,Beam or Deck Wood Joist,Beam or Deck MINIMUM AND with or without storage,penthouse equipment r <br /> TO BE MODIFIEf[rl� <br /> WARM AREA ABOVE rooms,elevator machine rooms,concealed <br /> DIFFUSER WALL DIFFUSER WATER HEATER LIGHT UNDER 250W LIGHT OVER 25OW FOR THE LOCAL /////// spaces dedicated exclusively to and containing U v <br /> AREA BY THE /////// O only dwelling unit ventilation equipment, TYP. CPVC HANGER DETAILS 1E <br /> W J w <br /> INSULATION // / floor/ceiling spaces,elevator shafts,crawl SCALE:NONE w <br /> HEADS LOCATED OUTSIDE HATCHED AREAS MAY BE ORDINARY RATED SPRINKLERS CONTRACTOR. spaces,and other concealed spaces that are not LL Lj <br /> used or intended for living purposes. KEYNOTE LEGEND r W r <br /> =NO SPRINKLERS ALLOWED =INTERMEDIATE RATED SPRINKLERS ❑ =ORDINARY RATED SPRINKLERS / // O M <br /> 8.3.6 Sprinklers shall not be required in unheated <br /> Part Tag p <br /> enclosures at the building at entrances/exits as Q rn <br /> SPRINKLER PIPING ON WARM AREA O long as the dwelling unit has another I'1 w v <br /> RESIDENTIAL HEAT SOURCE DETAILS entrance/exit. O W m <br /> BOTTOM CHORD OF # Hydraulic Node Tag <br /> ROOF TRUSS COLD AREA BELOW W�/ (n a <br /> SCALE:NONE *SPRINKLERS BETWEEN 175-225°F ARE INTERMEDIATE. 8.2.5.7 Shadow Areas.Shadow areas Shall be LL <br /> 6 permitted in the protection area of a sprinkler as O Reference Tag L"L_ o <br /> TYP. TENTING DETAIL REV. TENTING DETAIL O long as the cumulative dry areas do not exceed <br /> SCALE:NONE SCALE:NONE 15 ftz per sprinkler. ❑ O <br /> # Underground Note Tag <br /> �# Remote Area Tag Q N <br /> o <br /> n <br /> M <br />
The URL can be used to link to this page
Your browser does not support the video tag.