My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3702 W MUKILTEO BLVD A 2024 HARBORS EDGE TOWNHOMES Plans 2025-08-14
>
Address Records
>
W MUKILTEO BLVD
>
3702
>
HARBORS EDGE TOWNHOMES
>
Plans
>
3702 W MUKILTEO BLVD A 2024 HARBORS EDGE TOWNHOMES Plans 2025-08-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2025 7:49:51 AM
Creation date
6/23/2025 11:46:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3702
Unit
A
Tenant Name
HARBORS EDGE TOWNHOMES
Permit
K2406-006
Year
2024
Notes
INSTALL NEW RESIDENTIAL FLOW-THROUGH SYSTEM IN TOWNHOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: K2406-006 HARBOR'S EDGE BLDG D NFPA ° M <br /> Site Address: 3702 W Mukilteo Blvd Unit A Z <br /> Applicant: Matthew Steele • • • • •• , • ' 13 DLL <br /> Application Date:06/21/2024 o Z <br /> Description: Install new residential flow-through system in townhouse 1 SITE SPECIFICATIONS <br /> Review Date: O6/24/2024 -- - Q LL <br /> AHI: City of Everett OWNER/LESSEE: <br /> A RELATED PERMIT: B2304-046 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> WEST MUKILTEO BLVD. CONCE TYPE: 0V_B04 Everett,WA 98208 1-1 <br /> EVERETT 97+00 98+00 99+00 N76U+OOB017'08"E 1016.80 100+00 STORIES: 3 (425)609-8074 <br /> PARCEL: 00433600004700 <br /> Everett Fire Dept.Permit Review <br /> Status:Approved GENERAL DESCRIPTION: <br /> Reviewed By:KBrown New single family attached townhome.The typical and mirrored plans are both shown for <br /> 06/24/2024 2:04:14 reference.This submittal is for one plan-type only. <br /> PM o ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------' <br /> ------------------------- LEGAL DESCRIPTION: <br /> EDGEWATER BLK 000 D-00-LOT 47 <br /> APPROVED <br /> PUBLIC WORKS DEPARTMENT FIRE FLOW <br /> 340.17 <br /> BY:THerman <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> DATE:06/25/2024 RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> CITY OF EVERETT REVIEWED FOR PERMIT FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> GRADE1.1,1-;.I rRAnF=151 rZ GRADE= P <br /> GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> FF, C BUILDING CODE: 2018 IRC with WA State Amendments <br /> Z Pq zz1$28 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System 0 <br /> 150.8 Passive purge system without backflow,preventer <br /> O <br /> 0.1 O O �� O O © AO SPRINKLER COVERAGE: 256 ftz per sprinkler listing <br /> wp D <br /> o N 1296 SF 1221 SF 1220 SF 1525 SF 1$25 SF 1220 SF 1220 SF 1220 SF 1216 SF <br /> SPRINKLER SPACING: 16'-0"max.between heads. <br /> FFc' FF1 FF;; PFS'153,1 FFc' 8'-0"max.from any wall. <br /> ' PAD=15�� PAD*157.j PAD453. A 151.1 PAD>750.8 8'-0"min.between heads. <br /> 152.3 <br /> 1 Fizz. <br /> SPRINKLER <br /> PAD> 0'`50. 76 PA �15g3 .3 Residentialfasteponse pendent sprinklers used throughout. N d <br /> �........... ............i ............... ............... ...........i .. ....... ........ 9 HAZARD CLASSIFICATION: <br /> to <br /> 26 Residential use throughout. u° <br /> g 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. s <br /> / <br /> 4 SUPPLY: C m n <br /> N 77°23'09" 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" u m` <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system M Y u <br /> riser. a y e an d <br /> � MiL <br /> CPVC COMPATIBILITY: N <br /> J jIN «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r••••••••••• �......•••••, r••••••••••_ i I i specifications booklet.For a complete and up-to-date product search, lease go to/ ° P P P ,• <br /> I FF'75 F ° FF'1�3.7 pF-153.g <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c u °L <br /> ? '153 PqD_ 3.7 PF=1$q 0 PAD;)51 Ap=75j piping caused by any products which are not approved for contact with it.Information o. v u .o <br /> i i i P/{De75j 4 ..151.7 AD'1520 B• 7 ,rq-�, 3 about products approved for contact can be found with the manufacturer. y F g y a <br /> FF�753. FF'35 FPF:15 O " O 11g GENERAL NOTES AND LIABILITY " ` <br /> Z PAD>15 4 PAD,' 3.4 pq 3.4 12g1 118 SF 1181 SF 1181 SF 1 SF `o .c <br /> 14 i51.4 q-151.4 SF 4ti v <br /> Install CPVC piping in accordance with manufacturer's instructions and ILL listing including y m <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° n a <br /> w a O GG concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of Z <br /> V 1282 130 O 3/8"gypsum board. All CPVC pipe shall be concealed. y x u - <br /> SF 1 SF 1301 SF GRADE=153.4 GRADE=154.0 a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured <br /> PARCEL NO. SW GRADE=154.0 W to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. <br /> F'>A <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related ui� OR <br /> - GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees <br /> e on with no insulation on the warm side of the a facing the heated interior. „ .. .' <br /> GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the <br /> SW GRADE=154.0 pipe Y PP 9 N, i <br /> Sub n.t for Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> Bldg D-Unit A Only GRADE=155.5 e <br /> GRADE=155.9 a y :C a Moore Fire Protection shall not be responsible for the ability of the structure to adequately <br /> OO support the fire sprinkler system or any appurtenances thereof. <br /> G - 1301 SF 73p1 SF 1300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapter m I e 1 c ee >6 <br /> O � 12. 1A �QLL <br /> 7G 1781 SF 7781 SF 1241 SF Pqq 158.3 PqD_:58.3 PqD 158.3 • 11/z"Poly or equivalent supply brought in by others.* r <br /> 1T FF'FS>2 P F�7576 PAD`f57,6 15@.3 58.3 r156.3 llh"combination domestic/fires sprinkler shut off valve •�.• ..�•.�*o- <br /> i, PAD,155.2 q `755.6 �155.6 I <br /> • ° by others Must be located before the domestic tee D1 f° u_ <br /> P O <br /> • I' •......•• ••••• r •No monitoring is required. b N J ti <br /> ... <br /> pressure-reducing <br /> es # R N Uw <br /> , E <br /> �.............• res - o ng domestic <br /> o! <br /> wsG 1........... •••••------- ----------- ------------- = domesticleak detectors,o Bother devices that II deterR Ovate m J p <br /> 0 <br /> O 9r <br /> 3 •flow are to be on the domestic-only side of the tee. O w v o t n <br /> Brass tee top outlet to be female-threaded to d V r= o m <br /> " O n accommodate male threaded CPVC adapter m o v <br /> Gu connection. N oo w <br /> V rl Q 0 7 J <br /> C a �° 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. LU LL1 ry v Z m <br /> O CD 01 <br /> MFP scope of work to begin here. 2 E' o ¢ o <br /> 1"check valve. M Q d u ui <br /> w v <br /> r-i LU LL a m o`: <br /> N 76°1648"E -- F ` ® 1"tee with flow switch wired to exterior bell by _q tD 0 w o- to o w <br /> others. <br /> 220.10 e n Z Mo <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection ` N <br /> u cup attached to sanitary sewer,left by plumber and O o+ <br /> m ®sized to accommodate the system flow demand of 27 r^ 3 <br /> \\ a O d .�Si gpm. V <br /> SITE PLAN // �\ UNDERGROUND NOTES m O 1"x 1"x 1/2"tee with 1h"x v4"bushing for pressure U <br /> v 16� All underground to be by others. A w 9auge.Three way valve included for pressure gauge. W W <br /> SCALE:1/16"=1'-0" � RISER SECTION 1� � a <br /> ❑A Modelled hydrant flow location KEYNOTE LEGEND LU -' <br /> SCALE:1/2"=1'-0" O r n j <br /> ❑B 6-in circulating water main • Part Tag in0 <br /> WARNING SIGN: STUB IN: o' <br /> v <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w m <br /> ❑C Tapto 1-in combined domestic/fire fire service T ) shutoff valve and shall state the following: # Hydraulic Node Tag <br /> U (Typical for all units 9: FLUSH TEST: 'a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain *Underground installer will be required to have a flush test completed and witnessed Op <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag I' y <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: x <br /> ❑# Underground Note Tag CIOo <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the � E <br /> remote toilet location.Plumber is to connect from adapter to toilet. 3: <br /> Do not remove this sign. �# Remote Area Tag Q N <br /> ❑F Riser location-see this page for detail(Typical for all units) = o <br /> n <br /> M <br />
The URL can be used to link to this page
Your browser does not support the video tag.