Laserfiche WebLink
U N <br /> � INN <br /> Figure V-4.7:Perforated Stub-Out Connection 06 z C:ON<_n <br /> N <br /> _O <br /> V ^� Moa <br /> W (� /r� "�o <br /> 0 z `/ �In <br /> Z <br /> random fill <br /> rULU � T <br /> I N co o NOTES IW <br /> 6" rater fabric <br /> W of <br /> NOTES 5"MAX 1. CATCH BTININSERTS SHALLBE REMOWDATTHE ZF <br /> ENDOFTHEPROIECT. ` IL.YL <br /> 1. ST u ZEDCONSTRUCIONENTRANCESHALL DRAINAGE GRATE TRIM 18'mn. w 4"ped Pipe r, ` _ <br /> MEETTIERMUIREMENTSOFNGWT STANDARD 2. CATCH BASIN INSERTS ARE ONLY TO BE INSTALLED IN v �p3w SPECIFICATION SECTION Ba13IJ1. RECMGE DATKIS PER WE G.CATCMANUFACTURES'S N <br /> RECOMMENDALLEDI CATCH INSIN INLET INSERTS 1 y"- "washed rack N <br /> GRATE FRAME SMLI BE INSTALLED IN CURB INLETS. C r7iQ <br /> OVERFLOW 6YPA55 � U <br /> BELOW INLET GRATE m O Q <br /> SEDIMENT DEVICE 3. CATCH BASIN INSERTS SHALL BE INSTALLED PRIOR TO �f U <br /> AND DEBRIS CLEANNGAM)GMMNGACTIVITY,ORUPoN Z lJ 2U <br /> PLACEMENT OFANEW CATCH IN. p <br /> '-"✓" FILTERED WATER PLACEMENTBAS 24"min. III h Q <br /> INSTALLDRIVEWAYOILVERT - 4. SE WHEN NTSMLLSONE IEDFRDMTHE UNIT W <br /> WHEN R BECOMES ONETHIRD FULLOR IN <br /> EISA ROADNDE OUCH PRESENT <br /> ACCORDANCE WOH THE MANUFARURES' <br /> PRESENTNT <br /> INSTRURIONS. <br /> S. SEDIMENTREMONALSHALLBEACCOMPLISHEDBY Trench X-Section <br /> REMOVING THE INLET INSERTS,EMPTYING,AND <br /> 25' REJNSTAILING M INTO THE CATCH BASIN.DO NOT <br /> TNGROAO WASH SEDIMENT INTO STORM DRAINS WHILE _ <br /> 30'MINTYPICAL CLEANING. <br /> 6. SUE THE BELOW INLET GRATE DEVICE(RED)FOR WE <br /> STORM WATER STRUCTURE OWILL SERVICE. slope <br /> _ _ ]. T/EBIGDSHALLHAVEABUILT-INHIG14LOWREOEF <br /> -' SYSTEM(OVERFLOW BYPASS). <br /> SECTION VIEW to road <br /> A PERMEABLE BALWTTYPICAL SEE B. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF <br /> P.y STANDgRDSPECIFICATON WEBIGOWITHOM WILL NOWECOLLECTED drainage System <br /> SECTION M3.9(1) MATERIAL <br /> LENGTH AS REQUIRED 100'MIN,EXCEPT VMIN \ RETDEVALSYSRM 9. MRFORMMAINTENANCEINACCORDMCEWIW <br /> MAYBE REOUCEDl050'MIN FOR TOPIGL � STANDARD SPEGFICATgN B-013(IS). 2'x 1 D' <br /> SITES WITH LESS THAN ONE ACRE <br /> level trench <br /> OF IXPoSEO SOIL OR APPROVED BY INSPECFOR <br /> ORNxAGE GRATE w/pert pipe <br /> PLACE CONSTRUCTION GE EDGE <br /> O OF <br /> SOIL <br /> STABIIIJATON HE CONSTRUCTION <br /> EWE OF THE ENTRANCE <br /> PROVIDE FULL WIDTH OF <br /> POADWAY TO THE CONSTRUCTION ENTRANCE, INGRE55/EGRESSARFA <br /> OR AS DIRECTED W THE ENGINEER 15'MIN <br /> NO SCALE Plan View of Roof <br /> XSINTEN CE MEETS <br /> NOTES[CEPTABLE SUBSTITUTE IF m <br /> g ISOMETRIC VIEW g BELOW INLET GRATE MAINTENANCE MEEK NOTES NOT TO SCALE <br /> CONSTRUCTION ENTRANCE WSDOT STD PLAN I-BD.SDa2 ACCEPTABLE SUBSTITUTE DEVICE Ma�LTmAss P <br /> A3 EVERETT EVERETT PUBLICWORKB �■,� g <br /> III WASHINGTON DEPARTMENT R III•WASHINGTON DEPARTMENT <br /> m, _ __ 1 a u u�, -G -T. Perforated Stub-Out Connection <br /> yg M CONSTRUCTION ACCESS SJ q ISOMETRIC VIEW STORM DRAIN INLET 1 3"xmfi Revised.rune 2016 <br /> i 201 i€ PROTECTION 210 DEPARTMENT OF <br /> i i ECOLOGY please see Rttp7AYwWeey.we.go�DjaVhtODM for copyright notice including permissions, <br /> State of Washington limitation of liability,and disclaimer. <br /> O <br /> DEPARTMENT OF ECOLOGY SWMMWW m <br /> CITY OF EVERETT STANDARD DWG 201 CITY OF EVERETT STANDARD DWG 210 <br /> 1 CONSTRUCTION ENTRANCE &TIRE WASH (BMP C105) z STORM DRAIN INLET PROTECTION (BMP C2024 C220 PERFORATED STUB-OUT w <br /> D 1.0 NO SCALE D 1.o NO SCALE s CONNECTION (BMP T 5.10C) <br /> D 1.0 NO SCALE <br /> NOTES NOTES I� <br /> ATTACHIN AMMNERTHAT POST SEE WSDOT STANMRD p O p Ih <br /> ASwMFA K5RRMLY SPED CXTICNS8 o.319)A L INSTALLWEEXD50FT1E51LTFEIN TOPOINT L CONNECTION TO SEWER MAIN MR SECTION LL' <br /> HE BYTHE BACKUP SERWIMY UPSLOR TO PREVENTSEDIMENT FROM J OF STANDARDSPEORCATONS FOR ROADS; <br /> LU <br /> SUPPORTIXAWTTRAT FLOMNGAROUND THE ENDS OF WE FENCE. NSWEANDMUND&CONSTRUCTION <br /> WSWT/AP A.OTYSPECIALPROVISIONS, <br /> MRUCESTHEFOTEXTIAL Z PERFORM MAINTENANCE IN ACCORDANCE WITH Me STANBARD DRAWING 6U. <br /> FORFABRICTFANNG FASTEN GISOTFMIU TO WSDO VMDARDWMMO TIMS M.3(9)A Y <br /> S'MAXIMUM IF <br /> POST EVERY 6"IN QC AND8013115). L INSTALL6"MINIMUM PIPESRE IN RIGHT OF O O <br /> GRTrAu_M AN ITO W W Om <br /> BACKUP SUPPORT CLEAN A0DOlONA1 WAY' (9 Z <br /> 3. SPrrc<$HALL XEVERBE RACED IN IOWSPoTS 3 U � <br /> 0.EANOUTREQUIRED OILDINSTAT <br /> ORSUMP IDGTDNS IFSPUCES ARE IOCATE0IN 3. INSTALL6"CLEAN OUT PER STANDARD.AVER.- LE PoINTS BUILDING CONNFCTOX. m W <br /> q3 LOWOR SUMP AREAS,TNLEDULESS O FENCE MAYNBDTO OVER45• DRAWING 60R. W S _ <br /> CBACRIFILUED OMPA-D '•r�/�S16(ty,JGRGTENYIAXE BE RBNSTALLED UNLESS OTHERWISE MPIIOV®. O O U <br /> COMPACTED �6/6lMIN GRADE) 4. PRIVATE SIDE SEWER PIPE DIAMETER: <br /> NATME SOIL ,_U, 4. INSTALLNLTFENOMPARALUELTOMAPPED 4"MINIMUM FOR SINGLE FAMILY <br /> INN MIN TENSILE STRENGTX, COHTDURUNRU. <br /> UV STANLI2FD 6"MINIMUM PoR ALL OTHER USES. <br /> k0=\` 5. DURING IXCAVATON,MINIMUT DISTURBRM <br /> THEGROUNDAROUNDWETHT ASMUCHASIS GENERAL NOTES <br /> FEASIBU,AND SMOOMSURFAQFOLLOWING L sEE SEcnoN]oFsrANDa1D <br /> EXCAVATION TO AVOID CONCENTRATING ROWS. SPECIFICATIONS FOR ROADS;NUDGE AND Q V) <br /> BURY GEOTETIfE '`` UNDERCUTTING FLOWS�QRATETOPREVENT <br /> IN TRENCH BIIRIXNO WIIDBD MUNICIPALCONSTRUCTION WSDOT/MWA 1 <br /> AXD CITYSPMAL PROVISIONSSECTON J J <br /> GEOTE)lTLL R)RSILTRNCE \ R4IXUPSUPPORi ]-18 FOR DETAILS AND REQUIREMENTS ON _ <br /> T §€ 5EE STANDARD SPEOFRATON v F~O� STEEL POST (TYRGL) LATERALS. <br /> II� SECTION93a211I,TANE6 \ ATYPICAL) 2 ALLCIFANOUTS EDTOGTCEIF INPA <br /> qRE T(T BEAOIUSON PRWMDE OIN PAVED W <br /> % AREAS PERSTANDARDDRAWING600, L W <br /> TYPICAL INSTALL <br /> L WOH WYESdIMNOARY'T'STRUCTf, W <br /> TYPICAL INSTALLATION DETAIL / AT NDG. STMIGHT'T'S ARE NOT PE WITTED. W <br /> FABRIC <br /> ATYPFOIC�� 4 4 CONNECTION 4. ALLOWABLE GRADES ARf 2%"""/FTI O �r� W <br /> MINIMUM TO 30 fiff/Fr)MAXIMUM. `�/ 0-1 <br /> INSTALL BACKUP SUPPORT FOR <br /> Lu <br /> THE GEOTETILE SEE STANDARD ��/ 5. SEWER MRIM,CH CHANGES <br /> UNEORI <br /> SPEORCATION SECTION BDL3(9)A 9 3 ANGLE POINTS.CHANGES IN UNFOR L u <br /> I _ _PROPERTY PROPERTY GRADE SHALL BE MADE WIRI MPROVED <br /> \v dG Alf DI✓E _ _ LLNE NT-nNGS. LL <br /> SPLICEDRNCESER S5HN1BECLO5EEN000HTOGETHER I L L b. NORMALLY ONLY ONE(l)CONNECTION TO O <br /> 6f0 Ib PREVEMSILT RBr ' YImo/ wsooE]sro RAxM l-3o.looz AcNcGE eTHROUGHTHE <br /> N UTE r ALLOW p � JJG <br /> } <br /> RNDTTHEOVRIAP. SEWERMAIN 1 SWRMNN ANESHOTW01)DIFFEREUYOUTS <br /> SPUCE DETAIL oxLr.owxFON-STRATWRPaSEs <br /> Y TRNCE <br /> WBADRUPSUPFOT <br /> ~U <br /> EXCEPTSEELPOSTREQUIRED LAYOUTS' 06 <br /> LAYOUT'A' <br /> ISOMETRIC EVERETT ■■■ucwoLLlls .EVERETT P■■uOW■■■E <br /> WASHINGTON DEPARTMENT Rg III•INAB HINOTON DEPARTMENT ^ <br /> 0 3)/201J gSlq 1 NO �L1 <br /> TEMPORARY SILT FENCE 214 33 TYPICAL SIDE SEWER LAYOUTS 601 iY <br /> F3 €€€ M U) <br /> F LJJ <br /> � CITY OF EVERETT STANDARD DWG 214 CITY OF EVERETT STANDARD DWG 601 <br /> City of Everett Permit Review 4 SILT FENCE DETAIL(BMP C233) s TYP. SIDE SEWER LAYOUTS <br /> EVERETT Status:Reviewed for Permit D 1.0 <br /> D 1 <br /> a 04/10/2023 1:41:13 PM .0 NO D 1.0 NO SCALE <br /> g #23409 <br /> Y:\23409\DWG\CONSTRUCTION\Z_CSE TITLE BLOCK.DWG(LQyoutENG)2/17/2023 3:43 PM <br />