Laserfiche WebLink
Permit#: K2407-003 <br /> Site Address: 5900 36th Ave W BLDG C <br /> Applicant: American Sprinkler Corporation <br /> L Application Date:07/10/2024 <br /> APPROVED EVERETT Description: Add and relocate fire sprinklers for <br /> PUBLIC WORKS DEPARTMENT Everett Fire Dept.Permit Review new walls and ceilings <br /> BY:Thad Newport Status:Approved Review Date: 07/12/2024 <br /> DATE:07/12/2024 Reviewed By:KBrown <br /> CITY OF EVERETT REVIEWED FOR PERMIT <br /> ' 07/12/2024 8:54:02 <br /> AM <br /> TENANT IMPROVEMENT NOTES <br /> f ,g5r7" Off 1. System designed per 2019 NFPA#13 edition and City of Everett. <br /> �F W4 2. All new fire sprinkler heads to be 155 degree quick response pendants. <br /> 1p 4 F4 <br /> B #6 3. All sprinkler heads are 155 degree extended coverage quick response. <br /> •( 4. All materials used shall be UL/FM approved for fire protection installations. <br /> k 5. All threaded joints to have ductile iron fittings. <br /> 6. All new 1"-211 piping to be black steel Sch.40,21/2"and larger piping to be Sch.10. <br /> J 7. System shall be put back into service at the end of each work day. <br /> OF-6 OF5 <br /> 8. Pipe hangers and method of hanging to be in accordance with NFPA#13. <br /> 9. All tests required witnessed by authority having jurisdiction.Monitoring and central <br /> alarm are existing and to remain and maintained by owner. <br /> F-1 <br /> 11. All piping sized per existing pipe schedule method per NFPA#13. <br /> //-y"AFF <br /> 12.Total Sprinklers; <br /> P,x �' YI (A)=Add New Fire Sprinkler Drops Qty: 20 <br /> (R)=Relocate Existing Sprinkler to New Location Qty: <br /> (C)=Change Existing Sprinkler to New Q.R.Sprinkler Qty: <br /> (P)=Plug Existing Sprinkler Location Qty; <br /> DESIGN CRITERIA <br /> 'L- <br /> F PER 2019 NFPA#13 EDITION LIGHT AND ORDINARY HAZARD OCCUPANCY. <br /> vl ` 2v g.l vl v.11por/ HYDRAULIC CALCULATIONS HAVE NOT BEEN PROVIDED WITH THIS <br /> r <br /> SUBMITTAL. <br /> u <br /> Related Permit#B2404-051 <br /> FF=== <br /> Parcel#28040300200100 <br /> __II _____ II II Architect: General Contractor: <br /> JPC Architects Westrock Construction <br /> Julia Cygan Jon Gebow <br /> 425-641-9200 206-850-8542 <br /> /\ REFLECTED CELING PLAN <br /> " 6CALL.18, 0" <br /> VICINITY MAP; SITE PLAN _ SPRINKLER LEGEND <br /> rnrroecnu: SYM. TYPE K-FACT. FINISH ORIFICE TEMP. QTY. <br /> \ POSSE 8 SUD y2•�(y�C I ® Vlctaulic V2708 OR Pendant 5.6 Chrome 1/2" 1fis 20 <br /> y 8 <br /> victaullc V3102 Q R Concealetl Pendent 6.8 white 1/2" 166 <br /> Y _ Vlctaulicights Dry Pendant 5.6 Bras. 1/2" <br /> 200 <br /> I I,, p Existing Upright Sprinkler Location 6.8 Chrome 112" 168 <br /> �y Vlctaulic V2704 Quick Response upright 5.6 Chrome 1/2" 200 <br /> iIlk .. I. �`f� <br /> TOTAL 20 <br /> v% <br /> P <br /> 561H sr <br /> BMW EK <br /> .1 1' ................................. <br /> Bzplrea• E........' <br /> LOCATION <br /> - a'•a FlHWASHINGTONE 9�RINKLERSTAT 8Vi EMSNCY <br /> PROJECT <br /> +uar sr up1 <br /> 432.079 cEo m`LL 13atlon <br /> PROJECT SITE �''i j A i8 7NC <br /> NORTH .............. <br /> EVERER.WACHINGTON <br /> mT _ <br /> PROJECT LOCATION /\ <br /> „ REVISIONS <br /> AME IGAIIV $ <br /> 2311 153rd Ave BE Snohomish,We 98290 Phone:425-3354645 Fax:425-335-4766 <br /> APPROVING AGENCIES CUSTOMER: Sports Art TI-Bridge Point Everett 600 <br /> City Of Everett ADDRESS: 6900 36th Ave West Bulking C Suite 100 <br /> Everett;AThln ton 98203 <br /> DRAWING N0. <br /> JOB NO. DRAWN BY: DATE SCALE <br /> NA Doug 7/10/2024 1 1/8"=1'-0" 1 1 of! <br />