Laserfiche WebLink
CITY OF EVERETT STORMWATER MANAGEMENT MANUAL <br /> Start Here <br /> Does the site have 35% or No No additional <br /> more of existing impervious requirements for <br /> coverage? redevelopment apply <br /> Yes <br /> No Is the total of the new plus replaced <br /> impervious surfaces 5,000 square feet or <br /> Is this aroad-related more, AND does the value of the proposed <br /> project? improvements—including interior <br /> improvements—exceed 50%of the assessed <br /> value of the existing site improvements? <br /> Yes <br /> Does the project add <br /> 5,000 sq ft or more of NO Yes <br /> new impervious No <br /> surfaces? <br /> Yes <br />(. Do new impervious <br /> surfaces add 50% or more No No additional <br /> to the existing impervious requirements for <br /> surfaces within the project redevelopment apply <br /> limits? <br /> Yes <br /> See Minimum Requirements <br /> #1 through#9 <br /> Figure 2.2 Flow Chart for Determining Additional Requirements for Redevelopment <br /> Volume/—Minimum Technical Requirements <br /> 2-5 <br />