1410 SEINER DR 2023 SOUTH FORK BAKING COMPANY Plans 2025-07-02
>
Address Records
>
SEINER DR
>
1410
>
SOUTH FORK BAKING COMPANY
>
Plans
>
1410 SEINER DR 2023 SOUTH FORK BAKING COMPANY Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 7:55:36 AM
Creation date
6/26/2025 10:34:55 AM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Tenant Name
SOUTH FORK BAKING COMPANY
Permit
K2305-014
Year
2023
Notes
SPRINKLER SYSTEM TI
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6+00 6+50 7+00 7+50 SEINER DRIVE 8+00 8+50 <br /> SCOPE OF WORK BY BURNS FIRE SYSTEMS <br /> THIS SUBMITTAL IS FOR THE MODIFICATION OF SPRINKLER PROTECTION TO CONFORM WITH NEW SD <br /> WALLS.SPACING OF SPRINKLERS IN ACCORDANCE WITH NFPA#13.ALL NEW EQUIPMENT TO BE FO FO ^ /� C`�/I,1 D O Q`. �� L X X IL X X X ❑ SD <br /> INSTALLED IN ACCORDANCE WITH NFPA STANDARDS.NEW OR REPLACED SPRINKLERS TO MATCH PIPING V G SYMBOLS: <br /> U J <br /> K-FACTOR,TEMPERATURE RATING,FINISH AND RESPONSE CHARACTERISTICS OF EXISTING T\\ K\\ ❑ Q T\\ 0 - Q`Tl`IT�II�TI�I� <br /> SPRINKLERS. Approximate Hanger Location <br /> HYDRAULIC DESIGN BASED ON OH1 OCCUPANCY.SYSTEM DEMAND DOES NOT EXCEED EXISTING N \ <br /> SYSTEM DEMAND AT BASE OF RISER AS REPORTED ON PLACARDS. +J Approximate Bracing Location <br /> (6)TOTALADDED -�- Approximate Location of Grooved Coupling K•,' - o <br /> NEW PENDANT HEADS SUPPLIED FROM J <br /> FLEX DROP AND NEW MECHANICAL TEE +O-O Elevation from Floor to Centerline of Pipe _ :' SS� X`_ <br /> -0 BOJ Elevation down from Joist to Centerline of Pipe R + ° R/14(4)TOTAL ADDED + LLLDING CORNER M LEI ' L7 <br /> NEW UPRIGHT HEADS SUPPLIED FROM -0 BOB Elevation down from Beam to Centerline of Pipe - +++++ N: 367368.89NEW MECHANICAL TEE (0'-0") Center to Center Dimension of Pipe ++ L65 +�'+ <br /> +++++ E: 1302068.25 L6 9. <br /> ALL PIPING SHOWN IS EXISTING AND TO REMAIN U.N.O. 0'-0" Cut Dimension of Pipe + L66 + 64 <br /> ++++++ L63 PROTECT EXISTING v 18 - .s AREA OF WORK IN THIS SUBMITTAL <br /> L67 + + + STORM PIPE <br /> Calculation results for Design Area 1 -New Kitchen and Seating area CD HydraulicReference Point L68 + + <br /> This system as shown on company print no dated Rise Dro SEE LANDSCAPE FOR <br /> for South Fork Bakery at Pod of Everett 832 80th St SW O e p �`�"^ '�''`�contract no is designed to discharge at a mte of 0.15 gpm/it'(L/min/m')of Boor area over �'. I i L62 CONCRETE SCORE PATTERN _ _ <br /> ® Main Sprinkler Riser ��JJ AND JOINT CONTROL *� ;- <br /> a maximum area of 967.5 ft' when supplied with water at a rate of 254.8 gom at I(osi at the base of the rises + <br /> Hose stream allowance of is included in the above. + + Ll - LIGHTING PLINTH, <br /> (NAS) No Automatic Sprinklers + - - L5 ,�L12 ADA RAMP <br /> Occupancy classification:OHi Number of heads flowing:ll +PACIFIC RIM' I + - SEE ELECTRICAL <br /> Commodity classification: System Type: Wet (NTS) NOT TO SCALE - +++PLAZA <br /> AND HANDRAIL <br /> Maximum storage height: Maximum velocity: 14.99 iVs -- I <br /> Storage arrangement: +++++ I + <br /> Flow from In-Rack sprinklers: O gpm pressure Required at Source: 45.3 psi ++++ 2 a L - I _ I L33 J d cL31 L59 L58 L28_ 0 0 <br /> Flow from Overhead sprinklers: 254.8 gpm Pressure Available at Source: 78.4 psi + + - <br /> Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 33.1 psi + + 'L3:' L42' 41, ! 136 - L34 <br /> Flow from Outside Hoses: Ogpm ++ _ - L39 r + +• + L60- �L32+ + + <br /> L61 <br /> Other it flows: 0 gpm <br /> Total flow in system piping: 254.8 gpm <br /> Additional now at/beyond source: 0 gpm O <br /> Total of all Bows: 254.8 gPm 1 SITE PLAN <br /> FOR REFERENCE ONLY <br /> NO WORK <br /> (4 <br /> ,o <br /> NOT LESS MAN 2" NOMINAL MUTH (1 1/2') <br /> UP TO 31/2' PIPE; NOT LESS THAN 3' <br /> NOMINAL NDTH 4'h 5 PIPE.�� <br /> 18 <br /> 19 W1 <br /> 2QD <br /> F -- <br /> Source Information <br /> 21/2„ Date of Flow Test/Info: 5/11123 <br /> Location of flow test data rl' .11 2 112 <br /> z r BASE OF RISER <br /> Source of flow test data: Q�l <br /> CALC PLATE 16 MINIMUM 21/2' FROM BOTTOM FOR BRANCH ONES, <br /> MINIMUM 3" FROM BOTTOM FOR MAIN LINES. <br /> Wet System 2 1/2" Source Data Points PumpOR THICKI(E <br /> Data Int THIS REQUIREMENT SHALL NOT APPLY TO 2° <br /> N - OR HIR NNMNC STRIPS RESTING ON TOP OF S1EEL <br /> - Pressure Flow Pressure IF], N <br /> 130 1 1 9DEN,NDER <br /> 85 0.00 56jT (Sill <br /> I <br /> . <br /> add 2 1/2"Tee J <br /> 76.8 287.7 - D sign Area 1 Wet System <br /> _ <br /> y 15 110 109 1 10 N w Kitchen and Seating area <br /> di 2 112 11 1 Demand Calculations using Hazen-Williams Method <br /> EXISTING 1 z° LINES Occupancy Classification: OH1 <br /> 130 130=�f 130 1 DIE sign Area Density: 0.15 <br /> aPo 5. 5.6 Additional Outside Hose: 0 <br /> DE sign Area Size: 967.5 <br /> BFI - EXISTING 2 z' MAIN 15 1 t5 .15 N s: Reduced for QR heads and 13'max celing <br /> $ I height U.L. LISTED VICTAULIC AH-2 Flexible Sprinkler Drop <br /> rift 12 O _ HANGERS TO BE PROVIDED ON STEEL PIPE ARMOVERS WHICH EXCEED 24" IN LENGTH <br /> 08 212 7 10 1 <br /> RISER PLAN 2 2 2 0 � \ 2 112 <br /> FOR REFERENCE ONLY 09 O o BRANCHUNE AND NEW,'ARMOVER <br /> NO WORK <br /> MECHANICAL TEE WHERE REQUIRED <br /> 40 130 1 3 30 1 130 <br /> 5.6 5.6 Multi-Part Bracket <br /> 7 7 7 <br /> 15 1 15 Adjustable Hub <br /> 103 102 0� <br /> 11z <br /> 2" 112 112 2 112 <br /> I <br /> Sprinkler Head <br /> 5.6 1�30 1 <br /> 5.6 ,4 5.6 _0 -05. <br /> 7 DA Name: 1 7 <br /> 15 DA Area:96 569 <br /> ��I I <br /> 7 _T <br /> OFIRE oPROTECTION PLAN N <br /> First <br /> NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN <br /> W ___ _ _ __ DATE DESCRIPTION BY �i <br /> -�- WICATE OFC STATE SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL BFPS, INC South Fork Baking T. 1, AND DETAILS <br /> CERTIFICATE OF COMPETENCY � 20 <br /> uPR BRASS 155 5.so I/2" v2704 V1cTAUL v2+04 EXISTING HEADS AT ROOF <br /> \ :FIRE PROTECTION SPRINKLER SYSTEMS PERMIT NO. <br /> Z a UPR BRASS 155 5.so I/2" v2704 V1cTAUL v2704 NEW PENDANT HEADS P.0.B. 1110 <br /> Devid Yates CONTRACT N0. <br /> auto 0898-C LeWe13 OO s PEND CHROME Iss sso I/z" Tv323I rrco rr-Efts NEW UPRIGHT HEADS 1410 Seiner Dr Ste 103 <br /> 8urn9FireProtectionSystems,Inc. GRANITE FALLS, WA <br /> B SFPB bU DRAWN BY CITY OF DVYATES <br /> ERETT <br /> 5,16/23 Expnee: <br /> s: Everett, WA 98203 <br /> ,Sq 721312 SCALE NOTED <br /> '.-nature .... ....... _Date r 425-388-0124 DATE s/,s/zs <br /> DESIGN QUESTIONS 360-580-1062 CONTRACTOR: DIATEo FP 1 <br /> PLO ED <br />