Laserfiche WebLink
19011 Wood-Sno Road NE, Suite 100 <br />Woodinville, WA 98072-4436 <br />Phone:425-814-8448 <br />Fax: 425-821-2120 <br />Benton Square TH Revision Date: 1/11/2021 <br />Unit Type'B' <br />Criteria <br />Code: 2018 IBC <br />Allowable Stress Design (ASD) <br />J <br />Seismic Design: ASCE 7-16: 12.8 Equivalent Lateral Force Procedure <br />Wind Design: ASCE 7.16: Ch. 28 Envelope Procedure, Low Rise <br />Risk Category: <br />Snow Importance Factor <br />Ice Importance Factor - Thickness <br />Ice Importance Factor - Wind <br />Seismic Importance Factor <br />Spectral Response, Short Period <br />Spectral Response, 1-s Period <br />Site Class based on Geotechnical Report <br />Site Class: <br />Site Coefficient <br />Site Coefficient <br />II - Other Structures <br />Is = 1.00 <br />l; = 1.00 <br />/w = 1,00 <br />le = 1.00 <br />10 <br />!f Table 1.5-1 <br />Table 1.5-2 <br />Table 1.5-2 <br />Table 1.5-2 <br />Table 1.5-2 <br />Ss = 1.392'S r; (Mapped) <br />St = 0.495 (Mapped) <br />Fa = 1.02 Table 11.4-1 <br />F = 1.81 Table 11.4-2 <br />w .. Table 20.3-1 <br />Structural Systems: <br />Light framed wells with shear panels <br />All other structural systems TL = 6 (Figs. 22-14 thru 22-17) <br />Response Modification Coefficient R = 6.5 Table 12.2-1 <br />Overstrength Factor 40 = 3Table 12.2-1 <br />Deflection Amplification Factor Cd = 4 Table 12.2-1 <br />Basic Wind Speed: 100 mph <br />Exposure to Wind: exposure e . Section 26.7.3 <br />Topographical Factor KzT = 100 <br />Date: 5/30/2023 <br />Page: 1-1.18 <br />