Laserfiche WebLink
Job Truss Truss Type Qty Ply Lowes Companies Inc <br /> J1162297 A01 Common Supported Gable 1 1 115104198 <br /> __,,,, Job Reference(optional) __ <br /> The Truss Company(Burlington),Burlington,WA-98233, Run:8.73 S Apr 3 2024 Print:8.730 S Apr 3 2024 MiTek Industries,Inc.Fri May 03 13:42:28 Page:1 <br /> ID:ISfUCPwk8ox1AtASdOzGKdzKBwR-RfC?PsB70Hg3NSgPgnL8w3u1TXbGKWrCDoi7J4zJC?f <br /> -2-0-0 15-0-0 30-0-0 32-0-0 <br /> 2-0-0 15-0-0 ( 15-0-0 ( 2-0-0 <br /> 4x4= <br /> 12 <br /> — — 11 13 <br /> 10 4 <br /> 13.98r 9 15 <br /> 8 16 <br /> 7 17 <br /> m 6 18 <br /> 5 19 <br /> 4 20 <br /> 6 3 21 <br /> Lo 2 22 <br /> —cam= 1 23 <br /> o 3fP - <br /> 43 42 41 40 39 38 37 36 35 34 33 32 31 9 28 27 26 25 24 <br /> 3x4= 3x6= 3x4= <br /> I 30-0-0 l <br /> Scale=1:59.4 <br /> Plate Offsets(X,Y): [2:0-0-6,Edge],[22:0-0-6,Edge] <br /> Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.26 Vert(LL) n/a - n/a 999 MT20 185/148 <br /> (Roof Snow=25.0) Lumber DOL 1.15 BC 0.07 Vert(CT) n/a - n/a 999 <br /> TCDL 8.0 Rep Stress Incr YES WB 0.05 Horz(CT) 0.00 48 n/a n/a <br /> BCLL 0.0* Code IBC2018ITPI2014 Matrix-MS <br /> BCDL 7.0 Weight:145 lb FT=20% <br /> LUMBER 4) Unbalanced snow loads have been considered for this <br /> TOP CHORD 2x4 HF No.2 design. <br /> BOT CHORD 2x4 HF No.2 5) This truss has been designed for greater of min roof live <br /> OTHERS 2x4 DF Stud load of 20.0 psf or 1.00 times flat roof load of 25.0 psf on <br /> BRACING overhangs non-concurrent with other live loads. <br /> TOP CHORD Structural wood sheathing directly applied or 6) All plates are 2x4 MT20 unless otherwise indicated. <br /> 6-0-0 oc purlins. 7) Gable requires continuous bottom chord bearing. <br /> BOT CHORD Rigid ceiling directly applied or 10-0-0 oc 8) Gable studs spaced at 1-4-0 oc. <br /> bracing. 9) This truss has been designed for a 10.0 psf bottom <br /> REACTIONS All bearings 30-0-0. chord live load nonconcurrent with any other live loads. <br /> (Ib)- Max Hor z 2=64(LC 10),44=64(LC 10) 10)*This truss has been designed fora live load of 20.0psf <br /> Max Uplift All uplift 100(Ib)or less at joint(s) on the bottom chord in all areas where a rectangle <br /> 2 24,25,(lb) <br /> 26 s8, 3-06-00 tall by 2-00-00 wide will fit between the bottom <br /> 22, 2, 36,, 5, 6, 7, 8, 929,31,4 chord and any other members. <br /> 33,35,38 11)Provide mechanical connection(by others)of truss to <br /> Max Gray All (Ib) at joint bearing plate capable of withstanding 100 lb uplift at joint <br /> l reactions24,25,2 2507,(lb) <br /> 28,or2 less 31,tjo (s)2,22,35,36,37,38,39,40,41,42,43,33,32,31, <br /> (s) 34,35,36,37,38,39, 1,32,1, 29,28,27,26,25,24,2,22. <br /> 33,33,34 37,3 ,3 12)This truss is designed in accordance with the 2018 <br /> 42,431(LC except 42 1(LC 1),1), International Building Code section 2306.1 and <br /> 48=291(LC 1) referenced standard ANSI/TPI 1. <br /> FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250 LOAD CASE(S) Standard <br /> (Ib)or less except when shown. <br /> NOTES 4 .j.P . <br /> 1) Wind:ASCE 7-16;Vult=110mph(3-second gust) <br /> Vasd=87mph;TCDL=4.2psf;BCDL=4.2psf;h=25ft;Cat. �► <br /> II;Exp B;Enclosed;MWFRS(envelope)exterior zone; • ti4 <br /> cantilever left and right exposed;end vertical left and <br /> . 1� ; <br /> r ght exposed;Lumber DOL=1.60 plate grip DOL=1.60 +A;Pitt^ y:` / <br /> 2) Truss designed for wind loads in the plane of the truss <br /> only. For studs exposed to wind(normal to the face), : : " ' <br /> see Standard Industry Gable End Details as applicable, <br /> •e <br /> or consult qualified building designer as per ANSUTPI 1. m- <br /> 3) TCLL:ASCE 7-16;Pf=25.0 psf(Lum DOL=1.15 Plate <br /> DOL=1.15);Is 1.0;Rough Cat B;Partially Exp.;Ce=1.0; /// „, � <br /> Cs=1.00;Ct=1.10;IBC 1607.11.2 minimum roof live load I , „., t2F <br /> applied where required. .. , <br /> May 6,2024 <br /> II r <br /> A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI/-7473 BEFORE USE. <br /> Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. <br /> Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown <br /> is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the <br /> erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding <br /> fabrication,quality control,storage,delivery,erection and bracing,consult ANSUfPt1 Quality Criteria,DSB-89 end BCSI1 Building Component .17,, ��.f�y� <br /> Safety Information available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719. 1,11e Liy,V SSCO XNC. <br />