Laserfiche WebLink
2 3 4 5 6 <br /> III <br /> COLD WATER LINE <br /> E �8 <br /> I! A <br /> SHUT-OFF VALVE <br /> _ ARCHITECTURE ; <br /> TRAP PRIMER VALVE - <br /> VACUUM BREAKER PORT - - <br /> DISTRIBUTION UNIT(S) <br /> CONSULTANT: <br /> E (WHERE REQUIRED) E <br /> O <br /> i <br /> WALL <br /> -8„ FLOOR SINK,FLOOR <br /> / DRAIN OR HUB <br /> +(/ DRAIN CONDENSATE "N <br /> , 45"BEVEL VENT C TPE <br /> CUT TP <br /> AIRGAP .. <br /> 8"x1" <br /> CONNECT TRAP PRIM ER <br /> INLET TO FIXTURE <br /> OUTLET TAILPIECE SIDEiEu1 _ <br /> OF TRAP 3 <br /> NOTES_ - • <br /> CONDENSATE <br /> PRO <br /> 1. CLEVIS TYPE PIPE HANGER J \��//fJ <br /> DISCHARGE CONNECTS <br /> i, PROVIDE ACCESS PANEL IN WALLS AT TRAP PRIMER UNIT LOCATIONS. 0 q <br /> 2. THREADED ROD CUT TO LENGTH TO SINK SIDE OF TRAP ♦�w4O:�Fa+ <br /> 2 FINISHED I FLOOR SHALL BE MOUNTED ONE <br /> RY 2OF FEET OF FIR MER LLIINE.BOVE THE 5 3. SHIELD FOR INSULATION-LENGTH i ¢ pF 1Y45 <br /> 1.5 TIMES INSULATION DIAMETER z` Y <br /> y t <br /> 3_ INSTALL TRAP PRIMER PIPING AND UNIT PER ; ► <br /> MANUFACTURER'S RECOMMENDATIONS.PIPING MUST SLOPE 4. INSULATION <br /> TO INT OF CONNECTION TO DRAIN WITHOUT TRAPS IN <br /> PIPING - 5. CARRIER PIPE <br /> *FyCN'AI,r.�1 <br /> ��TRAP PRIMER INSTALLATION PIPE HANGER -CLEVIS TYPE1 CONDENSATE TO SINK TAILPIECE <br /> TENANT <br /> IMPROVEMENTS <br /> FOR <br /> PIPE 2D:. HOPEWORKS <br /> SEALANT _,,-PIPE INSULATION GROUT SLOPE <br /> i/ TO D„ <br /> PIPE INSULATION DRAIN INLET r(DIAMETER)l STRUCTURAL <br /> CONCRETE f FLOOR AT <br /> ° ° 0 3315 BROADWAY <br /> BACKING PIPE SEALANT BACKING d a 4I STRAINER EXTENSION EVERETT, WA <br /> MATERIAL MATERIAL DRAIN INLET STRAINER <br /> AS REQUIRED AS REQUIRED <br /> CORED HOLE t <br /> u PIPE THRU INTERIOR WALL WITH PIPE INSULATION cc PIPE THRU FLOOR WITH PIPE INSULATION 44 <br /> 2 PERMIT S E T <br /> 08/29/2022 <br /> PIPE 3 <br /> SEALANT RISER <br /> CLAM' <br /> This drawing is: <br /> C """WHERE 1 1.Cop Aight 2O17 pykem n,Inc. C <br /> / APPLICABLE J// 2.The Architect's Instrument of Professional Service. <br /> I4/ LEGEND 3.For use on this project only.Obtain Architect's <br /> DRAIN BODY MUT BE '� written permission forany other use or reproduction. <br /> STYLE WITH SEEPAGE COLLAR O APPROVED NON-SHRINK CONCRETE- <br /> PIPE EPDXY GROUT IN PROJECT <br /> BACKING ANNULAR CORE SPACE&SURFACE <br /> MATERIAL SLOPE, <br /> AS REQUIRED /1 20121-031 <br /> IVY'— DRAINLINE 2 SHEET METAL CLOSURE ANCHORED TO <br /> SEALANT BACKING CONCRETE FLOOR. <br /> PIPE THRU INTERIOR WALL WITHOUT PIPE INSULATION MATERIAL • <br /> `' AS REQUIRED - - <br /> PIPE THRU FLOOR WITHOUT PIPE INSULATION O SAFING MATERIAL 1-1/2 x DRAIN MARK DATE DESCRIPTION <br /> DIAMETER(8)MINIMUM STUD <br /> PIN SUPPORTS. <br /> O 1-1/2"x3"x12"ANGLE STEEL SUPPORT <br /> EACH SIDE MINIMUM(4) <br /> PIPE THRU INTERIOR WALL AND THRU STUD PIN FASTENERS. <br /> FLOOR WITH AND WITHOUT INSULATION CORE DRILL FLOOR DRAIN <br /> VANDAL RESISTANT <br /> COVER MARKED <br /> "SEWER" <br /> B B <br /> PROJECT <br /> BLACKTOP, /������ CLEANOUT HOUSING; PRINCIPAL IN CHARGE:I <br /> CONCRETE OREARTHFIILL V/� ��� LWAAN LANDSCAPE OR PROJECTPROJECT MANAGER <br /> � - AREAS-CHRISTY BOX PROJECT ARCHITECT: <br /> #F8 VEHICLE TRAFFIC JOB CAPTAIN: <br /> AREA-CHRISTY BOX <br /> #G-5 OR J.R.SMITH <br /> #4256 <br /> PIPE SLEEVE OF SIZE TO < <br /> PASS PIPE AND LEAVE o <br /> ROOM SEAL AIR TIGHT <br /> FOR PIPE INSULATION - WITH RUBBER CAP <br /> 20"x5"CONCRETE RING SECURED W/BAND <br /> CLAMP <br /> TERMINATE SLEEVE 1"INSULATION PIPE <br /> FLUSH WITH WALL SMITH#9329 SUPPORT <br /> SURFACE <br /> (AS NEEDED) <br /> Ye"BEND REQUIRED. <br /> (AT END OF RUN USE <br /> PIPE LONG SWEEP 90-ELL) <br /> I <br /> FILL ANNULAR GAPS EACH <br /> SIDE OF SLEEVE WITH ` DRAWING <br /> NONCOMBUSTIBLE <br /> SEALANT <br /> FINISHED WALL - <br /> SURFACE "Y"BRANCH SIZE AS <br /> A PIPE WALL PENETRATION' 3 GRADE CLEANOUT PLUMBING - A <br /> (� I2"=,'--6" i2"=,' DETAILS <br /> DRAWING NUMBER: <br /> ■ <br /> 2 3 4 5 6 <br />