Laserfiche WebLink
GENERAL NOTES: <br /> A. SEE REFLECTED CEILING PLANS FOR EXACT FIXTURE LOCATIONS. <br /> B. SUPPORT LIGHTS IN ACCORDANCE WITH SEISMIC REQUIREMENTS. ZGF <br /> ZIMMER GUNSUL FRASCA ARCHITECTS LIP <br /> C. WHERE SWITCHES ARE SHOWN GROUPED,PROVIDE A COMMON BACK BOX WITH <br /> LIGHTING FIXTURE BARRIERS AS REQUIRED BY NEC AND A COMMON SEAMLESS FACEPLATE. <br /> DENVER <br /> ALTERNATE LAMP INPUT LOS ANGELES <br /> TYPE DESCRIPTION MANUFACTURER MANUFACTURERS # CODE WATTS VOLT' COMMENTS NEW YORK <br /> L17 RECESSED FLAT LENSED RAB EZPAN FA 1 LED 1978 17 UNV PORTLAND <br /> TROFFER.NOMINAL 24-X 24'. LUMENS SEATTLE <br /> FROSTED LENS.0-10V DIMMING. 4000K WASHINGTON,DC <br /> FEILD ADJUSTABLE WATTAGE VANCOUVER,BC <br /> AND COLOR TEMP. <br /> 925 Fourth Avenue <br /> W Suite 2400 <br /> Seattle,Washington 98104 <br /> 'Voltage(s)listed are options available.Refer to electrical drawings for actual volt <br /> 208.823.9414 <br /> www.zgf.com <br /> ZGF Project Number 526447 <br /> 5 Consultant <br /> 1 2 : <br /> a- ® Stantec <br /> FLAG NOTES: W <br /> E ---- i� INSTALL TEMPORARY FIXTURES USING MC CABLE.REMOVE AT END OF <br /> _____ TEMPORARY USE OF SPACE. <br /> MIW FAMILY i 1,—111c © INSTALL TEMPORARY LIGHT SWITCHES/DIMMERS USING MC CABLE AND CUT IN' Full Design Team Roster on Sheet A0.01 <br /> RESTR M • J I,il—��L _-11 d BOXES.REMOVE AT END OF TEMPORARY USE OF SPACE. <br /> 1106.1 O Client and Project Information <br /> RESTROOM- <br /> L01 <br /> o MECHAI ICAL =, __ WOMEN <br /> T17 <br /> 01 L—J L17 Li _� 1105 ;tom <br /> ® 1 1 1 <br /> "e Seattle Children's <br /> L J DS HOSPITAL•RESEARCH•FOUNDATION <br /> Dr---1 r=� ---� a,b,c ❑ ^^ <br /> T ' D, L.L SCH North Clinic Lab <br /> o <br /> Expansion <br /> G L __ 181513th Street <br /> 13 1 f II PS L07 <br /> II b Everett,Washington 98201 <br /> Uj <br /> II <br /> °' o0 <br /> E.3 — — Original Issue <br /> 11 a o b r• r(�C� 1 m ___ os ASI-01 <br /> Revisions <br /> ti PS <br /> a,d L01 �� i 11 01 <br /> a,b,c <br /> f CORRIDOR <br /> e d c b C-11 <br /> HS a <br /> ®11d <br /> 01 E LOS O16 U <br /> PLAYROOM <br /> 1106 <br /> ' r Scale and Orientation <br /> m J <br /> TRUE NORTH PROJECT NORTH <br /> 4.00 DEGREES <br /> ' 0' 1' 2' 4' 8' <br /> Sheet Status <br /> M <br /> 0 2 4 8 12 <br /> a �TEMP LAB LIGHTING PLANS OD ti�oF e C <br /> W 1 inch plotted Feet 4' <br /> EL,,,, SCALE:AS INDICATED <br /> If measurement is other than <br /> I 1 inch then the plot is reduced. 1 O od y <br /> 2 I � <br /> -8 <br /> N <br /> 7 Sheet Title <br /> TEMP LAB <br /> LIGHTING <br /> PLANS <br /> Sheet Number <br /> r � <br /> EL1 .11 <br /> a Current Issue <br /> ASI.01 <br /> I I <br /> Current Issue Date <br /> L J 10/04/24 <br />