3817 SMITH AVE 2022 Plans 2025-06-27
>
Address Records
>
SMITH AVE
>
3817
>
Plans
>
3817 SMITH AVE 2022 Plans 2025-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2025 10:39:23 AM
Creation date
6/27/2025 10:39:16 AM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3817
Permit
M2210-064
Year
2022
Notes
REPLACE EXISTING RTU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 1. List of factory installed options(a) <br /> I 0-50%Motorized outside air damper Manual outside air damper <br /> Air-Fi®Wireless Communication Interface MERV 8 filters <br /> Quick Reference Guide E BACnet®Communication Interface(BCI-R) MERV 13 filters <br /> Barometric relief Multiple zone VAV(variable air volume) <br /> Belt drive motor Multi-speed indoor fan system <br /> Clogged filter switch NOVAR 2024 controls <br /> CompleteCoatV"(microchannel condenser coil) NOVAR 3051 controls without zone sensor <br /> e Condensate overflow switch NOVAR 3051 zone sensor <br /> Demand control ventilation wiring NOVAR return air sensor <br /> PrecedentTM - Standard Efficiency 4 Discharge air temperature sensing kit Powered convenience outlet <br /> COohng, Gas/Electric Economizer-comparative enthalpy ReliaTelT"controls <br /> � Economizer-dry bulb Single zone variable air volume(SZVAV) <br /> 3 to 10 Tons Packaged Rooftop Units Economizer-low leak,dry bulb Stainless steel drain pan <br /> Economizer-reference enthalpy Stainless steel heat exchanger • <br /> •Model Number: Used With: Fan failure switch Supply,return,and plenum air smoke detectors <br /> TSC Standard Efficiency Cooling Only(Electric Heat Optional) Fault detection&diagnostics(FDD);Meets CA Title 24 Through-the-base electric provision <br /> YSC Standard Efficiency Gas Heat Unit requirements <br /> FrostatT" Through-the-base gas provision <br /> Hail guard Unit mounted circuit breaker <br /> Hinged access panels Unit mounted non-fused disconnect <br /> Human interface-5-in.color touchscreen Unpowered convenience outlet <br /> ( LonTalk®Communication Interface(LCI) <br /> (a)Verify option availability in product catalog. <br /> January 2019 RT-PRCO37AE-EN 1 <br /> O 2019 Ingersoll Rand 0, Ingersoll Rand. ``-- i <br /> _..... ..............._..__............_...._..__............_......_._.._..... ......._..._ _..__. ................__.. ............ ................................................ ......_...._.....___...._._.........._........_._.._..........._..................................___.__.._......................_. ......._......_..____......_..................._..____......................._.._.__............_.._......____.._._.............,,\ <br /> Table 2. Standard efficiency,3 to 10 ton packaged rooftop performance data(cooling or gas) <br /> Nominal Size(Tons) 3 4 5 6 7.5 Single Compressor 7.5 Dual Compressors 8.5 10 <br /> Cooling Performance <br /> Supply Air(cfm)(a) 1,200 1,600 2,000 2,400 3,000 3,000 3,400 4,000 <br /> Tot/Sens Cap(MBh)(b)(C) 37.1/29.9 49.0/38.6 60.1/49.4 75.0/53.2 91.2/67.4 94.8/73.8 107.2/84.2 116.3/96.8 <br /> SEER/EER 14.0 14.0 14.0 11.2 11.2 11.2 11.2 11.2 <br /> • IEER(T/Y) N/A N/A N/A 12.9/12.7 12.9/12.7 12.9/12.7 12.9/12.7 12.9/12.7 <br /> Gas Heating Performance <br /> Low Heat(Input/output)-(MBh) 80/64.8 80/64.8 80/64.8 80.0/64.0 120/96 120.0/96.0 120.0/96.0 150.0/120.0 <br /> Medium Heat(Input/output)-(MBh) 100/81 100/81 100/81 120.0/96.0 150/120 150.0/120.0 150.0/120.0 200.0/160.0 <br /> High Heat(Input/output)-(MBh) 120/97.2 130/105.3 150/121.5 150.0/120.0 200/160 200.0/160.0 200.0/160.0 235.0/164.5 <br /> Other Information <br /> Net Weight(Lbs)-Gas Heat 472 492 522 710 760 847 885 1058 <br /> Net Weight(Lbs)-Electric Heat 431 452 498 667 679 797 837 960 • <br /> Roof Curb BAYCURB042A BAYCURB043A <br /> Unit Cabinet Size F C C D D D <br /> Filters(d)-Type Furnished Throwaway Throwaway Throwaway Throwaway Throwaway Throwaway Throwaway Throwaway • <br /> Number Size Recommended (2)20x30x2 ' (2)20x30x2 (2)20x30x2 (4) 16x25x2 (4)16x25x2 (4)20x25x2 (4)20x25x2 (4)20x25x2 • <br /> (a)Nominal cfm <br /> (b)Cooling performance is rated at 80/67/95 <br /> (c)All units listed utilize 3-phase voltage <br /> (d)Optional 2-inch MERV 8 and MERV 13 filters also available <br /> -----_ __.......-_ _---...._..----__._.........__...._. __.__ I <br />