Laserfiche WebLink
f <br /> I <br /> Notes from Site Visit of 9/30/2023 I `( <br /> • Some of the existing 4X4 posts are pressure treated and on 12X12 concrete a <br /> pedestals. o <br /> G M n <br /> • The existing stair treads are(3)2X4 flat. A a "� o i <br /> • The existing stair stringers are 2X12 cut to a 7/11 pitch. Z h ea• The existing 2X4 rails verticals are at 5.5"on center w/(2)1/4"X3"lags @ 8"on - <br /> center @ every other 2X4 vertical. 3 v 4 <br /> • There is an intermediate landing with 2X4 X bracing all four sides of the landing a o M <br /> that are nailed to the 4X4 posts. ��,, <br /> • There is a 32"minimum railing height. Code is 40" \ <br /> • The railing is 40"high at the top landing. iq : <br /> • The top stir rail set sways slightly laterally(from the intermediate landing to the <br /> top landing). to <br /> ti <br /> • The existing sidewalk is 3 to 4 inches thick. = w <br /> • The existing concrete pier blocks rest on the sidewalk. Q m <br /> O i <br /> • The top staircase slopes to the outside of the stairs. c <br /> • The top stair of the top staircase is not flush with the top landing creating a trip rip ,.i <br /> hazard. It <br /> v w <br /> • The middle riser of the top staircase has a broken and shimmed center riser a <br /> section that needs to be replaced. = <br /> • The lower stair of the top stair section that is bearing on the intermediate <br /> landing has an additional 2X4 flat that extends into the landing area and needs <br /> to be removed. • ti es �! <br /> U <br /> Major concerns: ,, <br /> • All the wood framing members need to be either pressure treated Item-fir <br /> material or painted. All painted surfaces will need to be properly maintained 4} <br /> and repainted as the painted surface wears. A <br /> N• The height of the top of the railing at any point in the staircase system needs to p <br /> be 40". o t <br /> • All footings under the existing 4X4 columns need to be placed on concrete <br /> xi <br /> footings that extend a minimum of 18"below finish grade for frost. g N a <br /> coo <br /> • The slope and lateral movement of the upper staircase need to be rectified along <br /> with removing the trip hazard at the top landing. <br /> • There needs to be an overrun of the handrail of 1'-0"at the base of the stairs. , f' � <br /> • The approximate riser to stair tread length needs to be 7:11 throughout the stair <br /> system(7"risers and 11"treads). 1. 4, <br /> • Need another intermediate wood bent at midspan of existing 9'-5"span of the j//� <br /> lower stairs in order for three 2X12 stringers to work for the stair support. The r/ °�i. <br /> minimum size of the supporting 4X needs to be upgraded to a 4x8 from a 4X6 <br /> upp9 g pg / c <br /> for both the existing and new intermediate bents. ?p .°s. <br /> • At the upper landing,an infill is needed at the juncture of the railings Grid 2. I AN, , AL <br /> 1 1 <br />