Laserfiche WebLink
• ' <br /> • <br /> c <br /> STRUCTURAL NOTES 1 <br /> CODE: ASTM 185. WWF shall be lapped one crosswire plus two inches(i.e.,8"for 6X6 mesh). t,, Or <br /> 2018 International Building Code(IBC) Reinforcing placing drawings shall be prepared by a qualified detailer in accordance with V 1 tV <br /> the most current ACI detailing manual. Submit placing plans to the structural engineer of q (,LIVE LOADS: Stairs: 100 psf record prior to fabrication. Any Grade 60 steel requiring bends shall be shop bent only z <br /> (preheating is required). Cold field bending is allowed only for Grade 40 rebar. $a .. M w zz'• <br /> LATERAL LOADS: Wind: 85 mph,Exposure B. (110 mph LRFD);Kzt=1.00 g a h t 1# o <br /> Seismic: Ss=1.160;SI=.406 All ASTM A-615(Grade 60)rebar shall be welded according to the most current edition b o <br /> of the American Welding Society(AWS)D12.1-75,"Reinforcing Steel Welding Code". 3 �e <br /> FOUNDATION: Soils Report Available: NO tz <br /> Specifically,E90 electrodes shall be used,and the base metal shall be preheated to the a ' '`m <br /> .w off] M <br /> temperature specified in the above reference. No weld shall be made within six(6)bar pi <br /> Design bearing pressure for new spread footings is 1500 psf Any foundation elevations diameters of any bend. All welders must be WABO certified. <br /> shown on the plans and sections are estimated. All footings shall bear on undisturbed M earth or compacted fill and shall extend to firm bearing when poor bearing is encountered NEW STRUCTURAL LUMBER&TIMBER: <br /> at elevations shown. Compacted fill shall be well-graded granular fill with not more than v <br /> 5%passing a#200 sieve. My structural fill required shall be placed in eight-inch All lumber shall be graded in accordance with current WWPA standard grading rules for 0 maximum loose lifts and compacted to 95%maximum dry density as determined by the Western lumber. Use the following species and minimum grades unless noted otherwise 1:1 a a' <br /> compaction procedure in ASTM D-1557. on the plans: <br /> NEW CONCRETE: rim Si <br /> Studs and Columns: DFL Standard w <br /> Wall Plates&Screeds DFL Utility tR, • <br /> Unless noted otherwise on the plans,all new concrete f'c shall be 2500 psi at 28 days. Joists&Rafters DFL# <br /> Minimum of 5&1/2 sacks of cement per cubic yard of concrete,and a maximum of J iS z <br /> 6&3/4 gallons of water per 94-pound sack of cement. A standard mix designsatisfying Heaer Flush Beams DFL# <br /> fYing 6X Beams DFL# �l eil w <br /> the above minimum strength is also acceptable. Provide a mix design data to the 6X Beams DFL# p <br /> engineer for review and approval if a standard mix design is utilized. - o es N <br /> All plywood shall be APA C-D interior grade with exterior glue and a minimum panel ID U Add plastocrete or pozzolith in accordance with the manufacturer's recommendations to index of 42/20 for floors,32/16 for the roof,and 16/0 for the walls.all concrete except footings. Concrete protection for reinforcing: <br /> NEW STRUCTURAL AND MISCELLANEOUS STEEL CONNECTORS: }c <br /> Bottom of footings: 3" v 1 t <br /> Wall exposed to earth: 2" All fasteners shall be fasteners as supplied by the Simpson Strong-Tie Company as r- <br /> Wall exposed to weather: s&l/2" depicted in their most current hardware catalog. 0 <br /> y, <br /> Wall inside face: <br /> Slabs: 3�,•> ' ro Pe S <br /> All steel not embedded in concrete or masonry shall receive one shop coat of an approved g y A. y Beams and columns(to ties): 1&1/2" primer paint. All bolts shall be ASTM A-307 unless noted otherwise on the plans. <br /> f All concrete in footings and walls,slabs and beams shall be poured in a monolithic pour SPECIAL INSPECTION REQUIRED FOR(as a minimum) ' <br /> Iunless shown otherwise or approved by the structural engineer or record prior to pouring. � t P.'Al* <br /> Aluminum conduit and accessories shall not be embedded in any concrete. I. Any epoxied connections to existing concrete. • ..1 <br /> l 2. Reinforcing steel for new spread footingsprior to closingo forms andpour �+ ,� <br /> NEW REINFORCING STEEL: f g p .r g of fy, toy <br /> Deformed billet steel ASTM A-615,Grade 60,fs=24,000 psi unless noted otherwise on MISCELLANEOUS: it <br /> ,y_;- , <br /> the plans. Lap all splices a minimum of 40 bar diameters. Provide elbow bars at wall <br /> corners and intersections to splice horizontal bars. Provide two#5 bars around all The contractor shall verify all dimensions and conditions in the field. Verify the size and <br /> openings with a minimum dimension of eleven(11)inches or greater in walls and slabs. location of all openings in the floor,the roof,and the walls with architectural,mechanical ' <br /> Extend the bars 2'-0"beyond openings or as far as possible and hook. Provide one#5 X( and electrical drawings. Provide temporary bracing as required until all permanent ,t - <br /> 4'-0"center diagonal bar at corners. Any welded wire fabric(WWF)shall conform to connections and stiffeners have been installed. <br /> • <br />