My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6321 BROADWAY 2025-07-15
>
Address Records
>
BROADWAY
>
6321
>
6321 BROADWAY 2025-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2025 8:08:20 AM
Creation date
6/27/2025 2:28:46 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6321
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ar:RObiolocly I-AhORATORy 150615pringdale St <br /> ASSOCRIVS, INCORPO2aU) Certificate of Analysis Suite 111 <br /> A Pace^Laboratory AIHA-LAP EMLAP#2189S1 Huntington Beach,CA 92649 <br /> 7148958401 <br /> Hawk Environmental Services,Inc. Date Collected: 3/7/2022 <br /> 7955 46th Ave.S Date Received: 3/10/2022 <br /> Seattle WA,98118 Date Analyzed: 3/10/2022 <br /> Attn:Ben Tressel Date Reported: 3/10/2022 <br /> Project:Landlord Law Air Project ID: 22008611 <br /> Condition of Sample(s)Upon Receipt:Acceptable Page 2 of 2 <br /> Footnotes and Additional Report Information <br /> Debris Rating Table <br /> 1 Minimal(<5%)particulate present Reported values are minimally affected by particulate load. <br /> 2 5%to 25%of the trace occluded with particulate Negative bias is expected.The degree of bias increases directly with the percent <br /> of the trace that is occluded. <br /> 3 26%to 75%of the trace occluded with particulate Negative bias is expected.The degree of bias increases directly with the percent <br /> of the trace that is occluded. <br /> Negative bias is expected.The degree of bias increases directly with the percent <br /> 4 75%to 90%of the trace occluded with particulate of the trace that is occluded. <br /> Quantification not possible due to large negative bias.A new sample should be <br /> 5 Greater than 90%of the trace occluded with particulate collected at a shorter time interval or other measures taken to reduce particulate <br /> load. <br /> Aeroblology Laboratory Associates,Inc.shall be responsible for all the information provided in the report,except when information Is provided by fire customer.Data provided by a customer <br /> can affect the validity of results and shall be clearly Identified.Results apply to the samples as received.Aerobiology Laboratory Associates,Inc.is not responsible for the sampling activity, <br /> such as air and water volume,area,and mass unit.The report shall not be reproduced except In full without the approval of the laboratory to ensure that parts of a report are not taken out of <br /> context.Data Interpretation of this report will be the client responsibility based on their sampling. <br /> " 1.PeniciillumlAspergillus group spores are characterized by their small size,round to ovoid shape,being unicellular,and usually colorless to lightly pigmented. <br /> There are numerous genera of fungi whose spore morphology is similar to that of the Penicillium/Aspergillus type.Two common examples would be l aecilomyces <br /> and Acremonium.Although the majority of spores placed in this group are Penicillium,Aspergillus,or a combination of both.Keep in mind that these are not the <br /> only two possibilities. <br /> 2.Ascospores are sexually produced fungal spores formed within an ascus.An ascus is a sac-like structure designed to discharge the ascospores into the <br /> environment,e.g.Ascobolus. <br /> 3.Basidiospores are typically blown indoors from outdoors and rarely have an Indoor source.However,in certain situations a high basidiospore count indoors may <br /> be indicative of a wood decay problem or wet soil. <br /> 4.The colorless group contains colorless spores which were unidentifiable to a specific genus.Examples of this group include Acremonium, It la <br /> I Beauveria,Chrysosporium,Engyodonlium microconidia,yeast,some arthrospores,as well as many others. <br /> i 5.Hyphae are the vegetative mode of fungi.Hyphal elements are fragments of individual Hyphae.They can break apart and become airborne much like spores <br /> and are potentially allergenic.Amass of hyphal elements is termed the mycelium.Hyphae In high concentration may be indicative of colonization. <br /> f 6.Dash(-)in this report,under raw count column means'not detected(ND)';otherwise'not applicable'(NA). <br /> 7.The positive-hole correction factor is a statistical tool which calculates a probable count from the raw count,taking into consideration that multiple particles can <br /> impact on the same hole;for this reason the sum of the calculated counts may be less than the positive hole corrected total. <br /> 8.Due to rounding totals may not equal 100%. <br /> 9.Analytical Sensitivity for each spores is different for Non-viable sample when the spores are read at different percentage.Analytical Sensitivity is calculated as <br /> spdm 3 divided by raw count.spr/m 3=raw counts x(1001%read)x(1000/Sample volume).If Analytical Sensitivity is 13 sprint 3 at 1t10%read,Analytical <br /> Sensitivity at 50%read would be 27 sprint 3,which is 2 times higher.Analytical Sensitivity provided on the report Is based on an assumed 100%of the trace being <br /> analyzed. <br /> 10.Minimum Reporting Limits(MRL)for BULKS,DUSTS,SWABS,and WATER samples are a calculation based on the sample size and the dilution plate on which <br /> the organism was counted.Results are a compilation of counts taken from multiple dilutions and multiple medias,This means that every genus of fungi or bacteria <br /> recovered can be counted on the plate on which it is best represented. <br /> 11.If the final quantitative result Is corrected for contamination based on the blank,the blank correction is stated in the sample comments section of the report, <br /> 12.The results in this report are related to this project and these samples only. <br /> 13,For samples with an air volume of<100L,the number of significant figures in the result should be considered(2)two.For samples with air volumes between <br /> 100 999L,the number of significant figures In the result should considered(3)three.For example,a sample with a result of 55,443 sprlm3 from a 75L sample <br /> using significant figures should be considered 55,000.The same result of 55,443 from a 150L sample using significant figures should be considered 55,400 spdm <br /> 3 <br /> 14.If the In/Out ratio is greater than 100 times it is indicated>10011,rather than showing the real value. <br /> Terminology Used in Direct Exam Reporting <br /> Conidiophores are a type of modified hyphae from which spores are born.When seen on a surface sample to moderate to numerous <br /> concentrations they may be indicative of fungal growth. <br /> Suzanne Blevins <br /> Laboratory Director <br /> tb 2022 Aerobiology Laboratory Associates,Inc.All rights reserved. <br />
The URL can be used to link to this page
Your browser does not support the video tag.